Philip Morris Polska
Al. Jana Pawła II 196, 31-982, Kraków, Poland
- Accredited standards
- 7
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 7 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM E2187
ISO 4387Cigarettes - Determination of total and nicotine-free dry particulate matter using a routine analytical smoking machine
ISO 8454Cigarettes - Determination of carbon monoxide in the vapour phase of cigarette smoke - NDIR method
ISO 10315Cigarettes - Determination of nicotine in total particulate matter from the mainstream smoke - Gas-chromatographic method
ISO 10362-1Cigarettes - Determination of water in total particulate matter from the mainstream smoke - Part 1: Gas-chromatographic method
ISO 12863Standard test method for assessing the ignition propensity of cigarettes
ISO 13110Cigarettes - Determination of menthol in total particulate matter from mainstream cigarette smoke with a smoking regime according to ISO 3308 (standard smoking regime) - Gas chromatographic method
ISO 10362-1; ISO 10315; ISO 8454; ISO 4387; ISO 13110; PN-EN ISO 12863; ISO 12863; ASTM E2187
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.
Scope as published by PCA
3 lines
ISO/IEC 17025
ActiveAB 1356
The scope document we hold says it is valid until 2028-08-19.
Accredited scope, certificate AB 1356
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | tobacco productsShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 1356
Scope of accreditation No. AB 1356
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 1356
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 20 z/of 24.02.2026
p.o. KIEROWNIKA DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1356 z dnia 26.07.2019 r.
Cykl akredytacji od 30.07.2024 r. do 19.08.2028 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No AB 1356 of 26.07.2019
Accreditation cycle from 30.07.2024 to 19.08.2028
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 20, 24.02.2026 1/4
Nazwa i adres / Name and address
PHILIP MORRIS POLSKA S.A.
Al. Jana Pawła II 196
31-982 Kraków
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/24 - Badania chemiczne wyrobów tytoniowych / Chemical tests of tobacco products
- N/24 - Badania właściwości fizycznych wyrobów tytoniowych / Tests of physical properties of tobacco
products
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB-07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB-07, available at PCA website www.pca.gov.pl
AB 1356 | - |
| 2 | ISO 10362-1; ISO 10315; ISO 8454; ISO 4387; ISO 13110; PN-EN ISO 12863; ISO 12863; ASTM E2187 | Wyroby tytoniowe; Tobacco products | See scope document |
| 3 | - | Wyroby tytoniowe; wkład tytoniowy do elektronicznego urządzenia podgrzewającegoShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 1356
Wydanie nr 20, 24.02.2026 r. 3/4
LABORATORIUM KONTROLI JAKOŚCI – PRODUKTÓW BEZDYMNYCH (QC-SFP)
Al. Jana Pawła II 196, 31-982 Kraków
Przedmiot badań/wyrób Rodzaj działalności/badane
cechy/metoda Dokumenty odniesienia
Wyroby tytoniowe E:
- wkład tytoniowy do
elektronicznego urządzenia
podgrzewającego
Stężenie związków organicznych w
areozolu:
- Nikotyna (Nicotine)
Zakres: (7,50 – 75,0) µg/ml
- Mentol (Menthol)
Zakres: (5,00 – 200,0) µg/ml
- Fenol (Phenol)
Zakres: (0,0100 – 0,190) µg/ml
- Gliceryna (Glycerin)
Zakres: (35,0 – 350,0) µg/ml
Metoda chromatografii gazowej z
detekcją spektrometrią mas (GC-MS)
Zawartość związków organicznych
(z obliczeń)
QMS-0030847
Wyroby tytoniowe:
- wkład tytoniowy do
elektronicznego urządzenia
podgrzewającego
Zawartość tlenku węgla w aerozolu
na wkład
(Carbon Monoxide per stick)
Zakres: (0,06 – 0,5) mg
Metoda spektrometrii w zakresie
podczerwieni (IR)
QMS-0008987 wydanie 18.0 z dnia
18.12.2025 r.
E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla
zakresu akredytacji laboratoriów badawczych.
Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie
przez akredytowany podmiot.
Wersja strony: A | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.