Registers refreshed 2026-11-20.See refresh dates
Taiwan

SGS Taiwan Ltd. Reliability Laboratory.

31, Wu Chyuan Road, New Taipei Industrial Park, New Taipei, 24886, Republic of China Taiwan, New Taipei, Taiwan

Visit website
A2LA 6709.01ISO/IEC 17025Register refreshed 2026-11-20
Part of the SGS group: 171 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
31
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 31 standard numbers and the 21 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60068 series16
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-5
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-13
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock

Certificate says EN 60068-2-27. Probably the same standard; not checked against the EN document.

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-42
IEC 60068-2-43
IEC 60068-2-60
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC5
IEC 60529Degrees of protection provided by enclosures (IP Code)+1 national

National versions in the same scope

CNS 14165identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 60598-1Luminaires - Part 1: General requirements and tests+1 national

National versions in the same scope

CNS 14335identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
IEC 61850-3
ISO4
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
IEC 60255 series3
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
Other standards3
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
DIN 75220
EN 50155Railway applications - Rolling stock - Electronic equipment

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

10 lines
A2LA

ISO/IEC 17025

Active

6709.01

The scope document we hold says it is valid until 2026-12-31.

View scope

Accreditation data refreshed from the A2LA register on .