SGS Taiwan Ltd. Reliability Laboratory.
31, Wu Chyuan Road, New Taipei Industrial Park, New Taipei, 24886, Republic of China Taiwan, New Taipei, Taiwan
Visit website- Accredited standards
- 31
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 31 standard numbers and the 21 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series16
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-5
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-13
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-42
IEC 60068-2-43
IEC 60068-2-60
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC5
IEC 60529Degrees of protection provided by enclosures (IP Code)+1 national
National versions in the same scope
CNS 14165identical to it
IEC 60598-1Luminaires - Part 1: General requirements and tests+1 national
National versions in the same scope
CNS 14335identical to it
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
IEC 61850-3
ISO4
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
IEC 60255 series3
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
Other standards3
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
DIN 75220
EN 50155Railway applications - Rolling stock - Electronic equipment
ASTM B117; IEC 60068-2-11; CNS 15481-4; CNS 3627; MIL-STD-202 Method 101; MIL-STD-810 Method 509; EN 50155; ISO 16750-4; ISO 9227; IEC 60068-2-42; IEC 60068-2-43; IEC 60068-2-60; EIA 364-65; GR- 63-Core; ISO 16750-4; CNS 15481-4; IEC 60068-2-1; EN 60068-2-1; MIL-STD-810 Method 502; IEC 60068-2-2; EN 60068-2-2; MIL-STD-810 Method 501; IEC 60068-2-27; IEC 60601-1-11, section 10.1; IEC 61850-3
IEC 60529; IEC 60598-1 Section 9; IEC 606011-1-11 Section 8.3; CNS 14165; CNS 14335 Section 9; CNS 15233 Section 5.12; ISO 20653; JESD 22-A104 Test Condition A, B, C, G, H, I, L, M; IEC 60068-2-14 Test Nb; ISO 16750-4; CNS 15481-4; MIL-STD-810 Method 503; MIL-STD-202 Method 107G Test Condition A, B, F; IEC 60068-2-14 Test Na; EN 50155; MIL-STD-810 Method 500 procedure I, II; IEC 60068-2-13; IEC 60068-2-5; MIL-STD-810 Method 505 procedure II; DIN 75220; IEC 60068-2-1; EN 60068-2-1; MIL-STD-810 Method 502
IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; EN 60068-2-78; MIL-STD-810 Method 507; MIL-STD-202 Method 103; MIL-STD-202 Method 106; JESD 22 A101; ISO 16750-4; CNS 15481-4; JESD 22-A104 Test Condition A; JESD 22-A104 Test Condition B; JESD 22-A104 Test Condition C; JESD 22-A104 Test Condition G; JESD 22-A104 Test Condition H; JESD 22-A104 Test Condition I; JESD 22-A104 Test Condition L; JESD 22-A104 Test Condition M; IEC 60068-2-14 Test Nb; ISO 16750-4; CNS 15481-4; MIL-STD-810 Method 503; MIL-STD-202 Method 107G Test Condition A; MIL-STD-202 Method 107G Test Condition B; MIL-STD-202 Method 107G Test Condition F; IEC 60068-2-14 Test Na; ISO 16750-4; CNS 15481-4; IEC 60068-2-1; EN 60068-2-1; MIL-STD-810 Method 502; ISO 16750-4; CNS 15481-4; IEC 60068-2-2; EN 60068-2-2; MIL-STD-810 Method 501; MIL-STD-202 Method 108; JESD 22 A108; ISO 16750-4; CNS 15481-4
IEC 60068-2-27; IEC 60601-1-11; IEC 61850-3; IEC 60255-21-2; IEC /EN 61373; EN 60068-2-27; EN50155; EN 61850-3; MIL-STD-202 Method 213; MIL-STD-810 Method 516; ISO 16750-3; CNS 15481-3; IEC 60068-2-1; EN 60068-2-1; MIL-STD-810 Method 502; ISO 16750-4; CNS 15481-4; IEC 60068-2-2; EN 60068-2-2; MIL-STD-810 Method 501; MIL-STD-202 Method 108; JESD 22 A108; IEC 60068-2-31
IEC 60068-2-2; EN 60068-2-2; MIL-STD-810 Method 501; MIL-STD-202 Method 108; JESD 22 A108; ISO 16750-4; CNS 15481-4; IEC 60068-2-27; IEC 60601-1-11; IEC 61850-3; IEC 60255-21-2; IEC /EN 61373; EN 60068-2-27; EN 61850-3; EN50155; MIL-STD-202 Method 213; MIL-STD-810 Method 516 Procedure I,II,III,V; ISO 16750-3; CNS 15481-3; IEC 60068-2-31 Section 5.2; MIL-STD-810 Method 516 Proc. IV; ISO 16750-3; CNS 15481-3; IEC 60068-2-6; IEC 60068-2-64; IEC 61373; IEC 61850-3; IEC 60255-21-1; IEC 60255-21-3; IEC 60601-1-11 Section 10.1; CNS 15233 Section 5.13; EN 61373; EN 50155; EN 61850-3; MIL-STD-810 Method 514; MIL-STD-810 Method 528 Type I; MIL-STD-167-1 Type I; JESD 22-B103 Table l Test Condition 1, 2, 3, 4, Table 2 Test Condition C, D, E, F; ISO 16750-3; CNS 15481-3
IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; EN 60068-2-78; MIL-STD-810 Method 507; MIL-STD-202 Method 103; MIL-STD-202 Method 106; JESD 22 A101; ISO 16750-4; CNS 15481-4; IEC 60068-2-31 Section 5.2; MIL-STD-810 Method 516 Proc. IV; ISO 16750-3; CNS 15481-3; JESD 22-A104 Test Condition A; JESD 22-A104 Test Condition B; JESD 22-A104 Test Condition C; JESD 22-A104 Test Condition G; JESD 22-A104 Test Condition H; JESD 22-A104 Test Condition I; JESD 22-A104 Test Condition L; JESD 22-A104 Test Condition M; IEC 60068-2-14 Test Nb; ISO 16750-4; CNS 15481-4; MIL-STD-810 Method 503; MIL-STD-202 Method 107G Test Condition A; MIL-STD-202 Method 107G Test Condition B; MIL-STD-202 Method 107G Test Condition F; IEC 60068-2-14 Test Na; ISO 16750-4; CNS 15481-4; IEC 60068-2-5; MIL-STD-810 Method 505 procedure II; DIN 75220; IEC 60068-2-6; IEC 60601-1-11 Section 10.1; IEC 61373; IEC 60068-2-64; IEC 61850-3; IEC 60255-21-1; IEC 60255-21-3; CNS 15481-3; CNS 15233 Section 5.13; MIL-STD-810 Method 514; MIL-STD-810 Method 528 Type I; MIL-STD-167-1 Type I; EN 61373; EN 50155; EN 61850-3; JESD 22-B103 Table l Test Condition 1; JESD 22-B103 Table l Test Condition 2; JESD 22-B103 Table l Test Condition 3; JESD 22-B103 Table l Test Condition 4; JESD 22-B103 Table 2 Test Condition C; JESD 22-B103 Table 2 Test Condition D; JESD 22-B103 Table 2 Test Condition E; JESD 22-B103 Table 2 Test Condition F; ISO 16750-3
IEC 60255-21-2; IEC /EN 61373; EN 60068-2-27; EN50155; EN 61850-3; MIL-STD-202 Method 213; MIL-STD-810 Method 516 Procedure I, II, III, V; ISO 16750-3; CNS 15481-3; IEC 60068-2-31 Section 5.2; MIL-STD-810 Method 516 Proc. IV; ISO 16750-3; CNS 15481-3; IEC 60068-2-6; IEC 60601-1-11 Section 10.1; IEC 61373; IEC 60068-2-64; IEC 61850-3; IEC 60255-21-1; IEC 60255-21-3; CNS 15233 Section 5.13; MIL-STD-810 Method 514; MIL-STD-810 Method 528 Type I; MIL-STD-167-1 Type I; EN 61373; EN 50155; EN 61850-3; JESD 22-B103 Table l Test Condition 1, 2, 3, 4,Table 2 Test Condition C, D, E, F; ISO 16750-3; CNS 15481-3; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; EN 60068-2-78; MIL-STD-810 Method 507; MIL-STD-202 Method 103, 106; JESD 22 A101; ISO 16750-4; CNS 15481-4
MIL-STD-810 Method 516 Proc. IV; ISO 16750-3; CNS 15481-3; IEC 60068-2-6; IEC 60068-2-64; IEC 61373; IEC 60601-1-11 Section 10.1; IEC 61850-3; IEC 60255-21-1; IEC 60255-21-3; CNS 15233 Section 5.13; EN 61373; EN 50155; EN 61850-3; MIL-STD-810 Method 514; MIL-STD-810 Method 528 Type I; MIL-STD-167-1 Type I; JESD 22-B103 Table l Test Condition 1, 2, 3, 4, Table 2 Test Condition C, D, E, F; ISO 16750-3; CNS 15481-3; IEC 60068-2-78; IEC 60068-2-30; IEC 60068-2-38; EN 60068-2-78; MIL-STD-810 Method 507; MIL-STD-202 Method 103; MIL-STD-202 Method 106; JESD 22 A101; ISO 16750-4; CNS 15481-4; JESD 22-A104 Test Condition A, B, C, G, H, I, L, M; IEC 60068-2-14 Test Nb; ISO 16750-4; CNS 15481-4; MIL-STD-810 Method 503; MIL-STD-202 Method 107G Test Condition A, B, F; IEC 60068-2-14 Test Na; ISO 16750-4; CNS 15481-4; IEC 60529; IEC 60598-1 Section 9; IEC 606011-1-11 Section 8.3
IP1X; CNS 14165; CNS 14335 Section 9; CNS 15233 Section 5.12; ISO 20653; EN 50155; ASTM B117; IEC 60068-2-11; CNS 15481-4; CNS 3627; MIL-STD-202 Method 101; MIL-STD-810 Method 509; ISO 16750-4; ISO 9227
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
10 lines
ISO/IEC 17025
Active6709.01
The scope document we hold says it is valid until 2026-12-31.
Labs with overlapping accredited scope in Taiwan
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.