HYDRUS LABORATORY
108 Chemin de Sainte Hélène, 06560, VALBONNE, France
- Accredited standards
- 1
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
NF EN ISO 9308-2
Read from the COFRAC scope document we downloaded on 2026-08-05. Register refreshed 2026-10-23.
Scope as published by COFRAC
4 lines
ISO/IEC 17025
Active1-7535
The scope document we hold says it is valid until 2030-05-31.
Accredited scope, certificate 1-7535
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NF EN ISO/IEC 17025:2017 | ENVIRONNEMENT / QUALITE DE L'EAU | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. Convention N° 8972
LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 2/4
Pour le Directeur Général et par délégation
On behalf of the General Director
Le Responsable du Pôle Chimie Environnement,
Pole manager - Chemistry Environment,
La présente attestation n’est valide qu’accompagnée de l’annexe technique.
This certificate is only valid if associated with the technical appendix.
L’accréditation peut être suspendue, modifiée ou retirée à tout moment. Pour une utilisation appropriée, la portée de
l’accréditation et sa validité doivent être vérifiées sur le site internet du Cofrac (www.cofrac.fr).
The accreditation can be suspended, modified or withdrawn at any time. For a proper use, the scope of accreditation and its
validity should be checked on the Cofrac website (www.cofrac.fr).
.
Seul le texte en français peut engager la responsabilité du Cofrac.
The Cofrac's liability applies only to the french text.
Comité Français d’Accréditation - 52, rue Jacques Hillairet 75012 PARIS
Tél. : +33 (0)1 44 68 82 20 – Fax : 33 (0)1 44 68 82 21 Siret : 397 879 487 00031 www.cofrac.fr | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 3/4
Section Laboratoires
ANNEXE TECHNIQUE
à l’attestation N° 1-7535
L’accréditation concerne les prestations réalisées par :
HYDRUS LABORATORY
108 Chemin de Sainte Hélène
06560 VALBONNE
FRANCE
Dans son unité :
- Hydrus Laboratory
Elle porte sur : voir pages suivantes | ||
| 4 | NF EN ISO 9308-2 | Eaux douces | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.