Registers refreshed 2026-11-20.See refresh dates
United States

Oregon Ballistic Laboratories, LLC

2873 22nd St SE, 97302, Salem, OR, United States

Visit website
A2LA 7169.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
39
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 39 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM35
ASTM D1003
ASTM D1044
ASTM D2136
ASTM D3574Standard Test Methods for Flexible Cellular Materials - Slab, Bonded, and Molded Polyurethane Foams
ASTM D3776
ASTM D5264
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E2353
ASTM E3004
ASTM E3062
ASTM E3068
ASTM E3078Exclusion

Limits written next to it

Conditioning of Hard Armor Test Items ASTM E3078/E3078M-23, Except 9, 11, 12

Exclusion. Written next to it on line 2 of A2LA certificate 7169.01.

Show all 35
ASTM E3086
ASTM E3107
ASTM E3110
ASTM E3111Exclusion

Limits written next to it

Ballistic Resistant Head Protection ASTM E3111-E3111M-22, Except 10.4

Exclusion. Written next to it on line 2 of A2LA certificate 7169.01.

ASTM E3112Exclusion

Limits written next to it

Ballistic-resistant Products and Shoot Packs ASTM E3112/E3112M-20, Except 9.5

Exclusion. Written next to it on line 2 of A2LA certificate 7169.01.

ASTM E3113
ASTM E3141
ASTM E3192
ASTM E3236
ASTM E3347
ASTM F588Exclusion

Limits written next to it

Window Assemblies, Excluding Glazing Impact ASTM F588-17

Exclusion. Written next to it on line 4 of A2LA certificate 7169.01.

ASTM F1233
ASTM F1450
ASTM F1642
ASTM F1915
ASTM F2156
ASTM F2248
ASTM F2469
ASTM F2781Exclusion

Limits written next to it

Resistance of Security Fence Systems ASTM F2781-15 Except Section 10

Exclusion. Written next to it on line 4 of A2LA certificate 7169.01.

ASTM F2912
ASTM F2927
ASTM F3038
ASTM F3561
EN3
EN 1063
EN 1522
EN 1523
Other standards1
ISO 16933Glass in building - Explosion-resistant security glazing - Test and classification for arena air-blast loading

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

7169.01

The scope document we hold says it is valid until 2027-12-31.

View scope

Accredited scope, certificate 7169.01

LineMethodMatrixRange
1MIL-DTL-46192C; ANSI Z89.1; ABNT NBR 15000:2005; ABNT NBR 15000:2020; ABNT NBR 15000:2022; MIL-DTL-46063H; MIL-DTL-32262; MIL-DTL-32375A; MIL-DTL-32375B; MIL-DTL-46027M; MIL-DTL-46100E; MIL-DTL-12560K; MIL-DTL-32332; MIL-DTL-46186A; MIL-DTL-46077G; ATPD-2352U; ASTM E3236-E3236M-21; DEAAluminum Alloy Armor Rolled Plate; Armor Plate, Aluminum Alloy; Armor Plate, Steel; Armor Plate, Titanium Alloy-
2ASTM E3111-E3111M-22; ASTM E3112/E3112M-20; ASTM E3113-23; TOP 10-2-216; TOP 10-2-210; MIL-PRF-32271; MIL-PRF-32565B; DEA; HPW-TP-0401.01B; SD-STD-01.01 Rev H; SD-STD-01.01 Rev G; 5-aa10; CFR-2011 Title 49 Volume 4 Part 223; ASTM E3110/E3110M-22; ASTM E3078/E3078M-23; ASTM E3068-20; ASTM E3086-20; DEA; DEA; MIL-STD-3027; MIL-STD-810H; FBI; AC No: 25.795-2A; 571.218; ASTM D3574-17; ISO 16933:2007; BS EN 1063:2000; ASTM E3062-16--
3NIJ-STD-0106.01; NIJ-STD-0101.04; NIJ-STD-0101.06; NIJ-STD-0101.07; NIJ-STD-0108.01; NIJ-STD-0117.01; NIJ-STD-0115.00; AEP-2902; PRF-15001A0019; T&EP 22/09/2007; ASTM E3004-22; AEP 2920 Edition A Version 1; AEP 2920 Edition A Version 2; AEP-55 Vol. 3; AEP-55 Vol. 1; AEP-55 Vol. 2; Stanag 4569; CO/PD 04-19F; CO/PD 00-03E; LPS 1270; LPS 1175; MIL-R-8573A; ASTM E3107/E3107M-23; ASTM E3141-E3141M-24; ASTM E3192-E3192M-20; NIJ-STD-0123.00; ASTM D2136-19e1; ASTM F2927-21--
4ASTM F3561-25,-23; ASTM F1915-98; ASTM F1642/F1642M-25,-17; ASTM D1003-21; ASTM F1450-12a; ASTM D3776/D3776M-20; ASTM F588-17; ASTM F2469-25,-20; ASTM F2156-17; ASTM E2353-21; ASTM D1044-24; ASTM E18-25,-24; ASTM F1233-21; ASTM F3038-21; ASTM D5264-98; ASTM F2781-15; UL 752 11th Edition, Section 3, 3.1, 12-17; UL 752 12th Edition Section 6-15; MIL-DTL-27422F, Sections 1.2.3, 4.5.8.4, 4.5.8.4.2, 4.5.8.4.3, Table II, 4.5.8.4.4, 4.5.9, 4.7.12-4.7.17; MIL-STD-3038; HPW-TP-0500.03; HPW-TP-0508; GSA-TS01-2003; TOP 10-2-208; MIL-STD-662F; BS EN 1522:1999Windows, doors, shutters, and blinds; Tank, Fuel, Crash-Resistant, Ballistic-Tolerant, Aircraft-
5BS EN 1523; SFI 4.1; SFI 4.3; SFI 7.1; SFI 7.2; SFI 14.2; SFI 14.21; SFI 14.3; SFI 14.4; SFI 14.5; SFI 14.6; NT-SENASP No. 003/2021; NT-SENASP No. 003-2021; ISO 16933:2007; BS EN 1063:2000; NIJ-STD-0117.01; T&EP 22/09/2007; AEP-55 Vol. 3; AEP-55 Vol. 2; Stanag 4569; ASTM F2927-21; ASTM F1642/F1642M-25; ASTM F1642/F1642M-17; GSA-TS01-2003--
6ASTM E3347/E3347M; DOS Blast SOP BLAST TESTING SOP FOR DS/PSD/RD; ASTM F2912; ASTM F2248; IMAS 10.30--
7

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited OREGON BALLISTIC LABORATORIES, LLC Salem, OR for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 24th day of February 2026. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7169.01 Valid to December 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2873 22nd St SE, Salem, OR, 97302, US

44.93916, -123.03312

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.