Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 2503.01 · 5 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2503.01) Revised 10/07/2025 Page 1 of 4 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 DIMENSIONAL MEASUREMENT, INC. 46989 Liberty Drive Wixom, MI 48393 Andrew Rauch Phone: 248 960 8801 CALIBRATION Valid To: December 31, 2026 Certificate Number: 2503.01 In recognition of the successful completion of the A2 LA evaluation process, (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements) accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Dimensional Parameter/Equipment Range CMC 2, 4 (±) Comments Bore Gages (2-Point) 3 Up to 100 mm 4.4 µm Gage block comparison Calipers 3 (10µm Resolution) Up to 300 mm Up to 600 mm Up to 1000 mm (8.2 + 0.02L) µm (11 + 0.02L) µm 24 µm Gage block comparison Calipers 3 (1µm Resolution) Up to 150 mm (0.7 + 0.03L) µm Gage block comparison Depth Micrometers 3 Up to 300 mm 15 µm Gage block comparison Dial & Digital Indicators 3 Up to 25 mm Up to 60 mm Up to 200 mm 2.9 µm 1.7 µm 7.6 µm Indicator checker Gage block comparison Depth Standards Up to 1 mm (0.097 + 0.19L) µm Profilometer & gage block comparison
to 1000 mm
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2503.01) Revised 10/07/2025 Page 2 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Feeler/Taper Gages 3 Up to 25 mm 3 µm Digital micrometer Gage Balls – Diameter Up to 100 mm 1.1 µm Gage block & bench micrometer Height Gages 3 Up to 965 mm (9.0 + 0.006L) µm Reference bar, gage blocks Micrometers3 Up to 300 mm (300 to 600) mm (0.91 + 0.005L) µm (7.6 + 0.009L) µm Gage block comparison Micrometer Standards 3 Up to 600 mm (2.8 + 0.003L) µm Reference bar, gage blocks, amplifier Parallels – Flatness & Parallelism Up to 2500 mm 3.6 µm CMM Pin & Plug Gages 3 Up to 100 mm Up to 25 mm 1.1 µm 2.8 µm Bench micrometer Digital micrometer Profilometer (0.4 to 3.2) µm Ra 0.051 µm Ra Roughness standard Roughness Standard Up to ≈ 6 µm Ra (0.045 + 0.014A) µm Ra Profilometer Radius Gages Up to 300 mm 12 µm Vision system Rulers – Length Up to 400 mm Up to 2000 mm (3.1 + 0.007L) µm (24 + 0.008L) µm Video system CMM w/ camera
to 2500 mm
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2503.01) Revised 10/07/2025 Page 3 of 4 Parameter/Equipment Range CMC2 (±) Comments Straight Edge – Straightness Up to 2500 mm 3.6 µm CMM Thread Plugs – Pitch Diameter Major Diameter Up to 25 mm Up to 25 mm 2.6 µm 1.1 µm Thread wires, bench micrometer Bench micrometer II. Dimension Testing/Calibration 1 Parameter/Equipment Range CMC2, 4 (±) Comments Length – 1D 5 2D 5 3D5 Up to 965 mm Up to 2 mm Up to 25 mm Up to 150 mm Up to 300 mm Up to 60 mm Up to 100 mm Up to (400 × 400) mm Up to (1000 × 800 × 700) mm Up to (2000 × 1200 × 1000) mm (0.42 + 0.004L) µm 0.43 µm 5.6 µm 9.5 µm 36 µm 4.1 µm 2.7 µm (2.7 + 0.006L) µm (2.2 + 0.005L) µm (3.1 + 0.004L) µm Reference bar comparison w/ amplifier Amplifier Bore gages Caliper Caliper Digital indicator Digital micrometer Vision system CMM (LH87) CMM (LH1210)
to 2500 mm
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2503.01) Revised 10/07/2025 Page 4 of 4 Parameter/Equipment Range CMC2 (±) Comments Length – (cont) 3D 3, 5 Up to 3600 mm 110 µm 99 µm CMM (faro arm edge) CMM (faro arm prime) Flatness Up to 2.6 µm 0.36 µm Optical flat & monochromatic light Surface Finish 5 ≈ 6 µm Ra (0.045 + 0.014Ra) µm Ra Profilometer Surface Finish 3, 5 ≈ 6 µm Ra 0.15 µm Ra Portable profilometer _______________________________ 1 This laboratory offers commercial calibration/ dimensional testing service and field calibration/ dimensional testing service. 2 Calibration and Measurement Capability Uncerta inty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal me asurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be great er than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in millimeters; A is the vertical amplitude in micro-meters. 5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
to 3600 mm
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited DIMENSIONAL MEASUREMENT, INC. Wixom, MI for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 23rd day of October 2024. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2503.01 Valid to December 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.