Capstone Calibration

7016 & 7024 Baker Blvd, 76118, Richland Hills, TX, United States

Visit website
A2LA 1593.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
1
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

1593.01

The scope document we hold says it was valid until 2026-01-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 1593.01

LineMethodMatrixRange
1ISO/IEC 17025:2005; ison to master square Parallelism Up to 36; IEC 17025; ANSI/NCSL Z540-1-1994 CAPSTONE CALIBRATION 7016ElectronicSee scope document
2-Electronic
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1593.01) 01/08/2024 Page 2 of 5 Parameter/Equipment Range CMC2, 4 (±) Comments Straightness 3 Up to 72 in (20 + 0.77L) µin Autocollimator Autocollimators Up to 10 arc-min 0.66 arc-sec Gage blocks & sine bar Calipers3 Up to 36 in (37 to 80) in (170 + 0.6R) µin (390 + 0.6R) µin Gage blocks Micrometers 3 Up to 24 in (83 + 0.6R) µin (180 + 0.6R) µin Gage blocks Digital & Dial Indicators 3 – Up to 6 in 0.000 010 in resolution 0.000 020 in resolution 0.000 050 in resolution 0.000 100 in resolution 0.000 500 in resolution 0.001 000 in resolution 12 µin 20 µin 46 µin 92 µin 440 µin 810 µin Gage blocks, ULM Height Gages 3 High Resolution Up to 48 in Up to 48 in (310 + 0.6R) µin (130 + 0.6R) µin Gage blocks Length Standards Up to 60 in (20 + 3.7L) µin Gage blocks, electronic indicator & amplifier, ULM Wires/Pins / Plug Gages & Outside Cylindrical Diameter Up to 3 in 17 µin ULM, gage blocks Plain Rings & Inside Cylindrical Diameter Up to 10 in 24 µin Ring gage comparator, gage blocks Thread Plugs – Pitch Diameter Major Diameter Up to 10 in 140 µin 17 µin 3 wire method ULM, gage blocks
to 72 in
3ASTM E18-to 12 in
4ASTM E18Test blocks10 to 250 lbfꞏin to lbfꞏft
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1593.01) 01/08/2024 Page 5 of 5 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of best measurement uncertainty, DL is the numerical value of the nominal length in inches of the diagonal, L is the numerical value of the nominal length, and R is the numerical value of the resolution of the device in microinches. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
6ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

7016 & 7024 Baker Blvd, Richland Hills, TX, 76118, US

32.80914, -97.23604

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.