PRO-LAB Usługi Chemiczno-Środowiskowe P.Drop, K.Drop S.C.
ul. Metalowców 7, 88-100, Inowrocław, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at PRO-LAB Usługi Chemiczno-Środowiskowe P.Drop, K.Drop S.C.?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 1053Active
Accredited standards
9Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidanceCertificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.
PN-EN 14253+A1:2011
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11
ISO 7243Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet bulb globe temperature) index
PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04
ISO 7730Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11
ISO 11079Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects
PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11
PN-Z-04008-7:2002+Az1:2004Name not checked yet
PN-Z-04008-7:2002+Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08
Scope as published by PCA
5 lines
ISO/IEC 17025
ActiveAB 1053
The scope document we hold says it is valid until 2029-05-31.
Accredited scope, certificate AB 1053
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | - | harmful factors - air; harmful and nuisance factors – noise, vibration, microclimate, energy expenditure | - |
| 2 | environmental | PN-Z-04008-7:2002+Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08 | Ambient air | 0.18 to 20.3 mg/m3 |
| 3 | environmental | PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11 | Ambient air | 0.1 to 18115 m/s2; mg/m3; ppm; dB; °C; dm3/min |
| 4 | environmental | PN-EN 14253+A1:2011 | Workplace environment | 0.02 to 35 m/s² |
| 5 | environmental | PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04 | Środowisko pracy – mikroklimat zimny; Środowisko pracy – mikroklimat gorący; Środowisko pracy – mikroklimat umiarkowany | -29 to 59 °C; %; m/s |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- M-LAB Mirosław PrackiPiechcin · ~15 kmPCAShares 5 accredited methods and materialsEN 14253+A1:2011EN ISO 11079:2008PN-N-01307:1994
- MS LAB Spółka z ograniczoną odpowiedzialnościąRypin · ~83 kmPCAShares 5 accredited methods and materialsEN ISO 11079:2008PN-N-01307:1994PN-Z-04008-7:2002+Az1:2004
- AQUANET Laboratorium Spółka z o.o.Poznań · ~101 kmPCAShares 5 accredited methods and materialsEN ISO 11079:2008PN-N-01307:1994PN-Z-04008-7:2002+Az1:2004
- Laboratorium Usługowo-Badawcze "Biochemik"Piła · ~108 kmPCAShares 5 accredited methods and materialsEN ISO 11079:2008PN-N-01307:1994PN-Z-04008-7:2002+Az1:2004
- Techno-Service Pracownia Badań ŚrodowiskowychGdańsk · ~185 kmPCAShares 5 accredited methods and materialsEN 14253+A1:2011EN ISO 11079:2008PN-Z-04008-7:2002+Az1:2004
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.