Ametek Singapore Pte Ltd. (Compliance Test Solutions)

20 Changi Business Park Central 2, #04-03/04, Singapore, 486031, Singapore, Singapore, Singapore

Visit website
A2LA 2939.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
14
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 14 standard numbers and the 12 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series5
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
IEC 61000-4-18
ISO4
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 7637 series3
ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
Other standards2
IEC 60060-1
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

2939.01

The scope document we hold says it was valid until 2025-12-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 2939.01

LineMethodMatrixRange
1ISO/IEC 17025:2017-See scope document
2ISO 7637-2 ISO 7637-3 ESD Simulators3; ISO 10605 Voltage Dips Simulators3; ISO 16750-2; IEC 61000-4-8; IEC 61000-4-4--
3IEC 61000-4-12; IEC 61000-4-18; IEC 60060-1; IEC 60950-1; IEC 61000-4-5-See scope document
4ISO 7637-2; ISO 7637-2 ISO 16750-2; IEC 61000-4-5; IEC 61000-4-12; IEC 61000-4-18-See scope document
5ISO 10605; ISO 11452-2; ISO 11452-4; ISO 7637-1; ISO 7637-2-9000 to 4500000000 Hz
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2939.01) 12/13/2023 Page 6 of 6 III. Time & Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments Frequency3 – Measure 10 Hz to 100 kHz 1 Hz to 1 GHz >1GHz to 8GHz 0.1 % 1.2 % 1.2 % DMM Oscilloscope Frequency counter Spectrum analyzer ______________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field Calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of Calibration and for other possible adverse effects such as those caused by transportation of the Calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC and indication of Range values, percentages are to be read as percent of reading or indication, unless noted otherwise. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
7ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.