Registers refreshed 2026-11-20.See refresh dates
South Korea

HCT Co.,

74, Seoicheon-ro 578 Beon-gil, Majang-Myeon, Icheon-Si, Gyeonggi-Do, 17383, South Korea, Icheon-Si, Gyeonggi-Do, South Korea

Visit website
A2LA 4114.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
28
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 28 standard numbers and the 26 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series10
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity testExclusion

Limits written next to it

IEC 61000-4-39 (Excluding 5.5,6.2, 7.2, 8.6)

Exclusion. Written next to it on line 1 of A2LA certificate 4114.01.

ISO8
ISO 178Plastics - Determination of flexural properties
ISO 179-1Plastics - Determination of Charpy impact properties - Part 1: Non-instrumented impact test
ISO 180Plastics - Determination of Izod impact strength
ISO 527-1Plastics - Determination of tensile properties - Part 1: General principles
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply linesExclusion

Limits written next to it

ISO 7637-3 (excluding DCC test method)

Exclusion. Written next to it on line 2 of A2LA certificate 4114.01.

ISO 8256Plastics - Determination of tensile-impact strength
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fieldsExclusion

Limits written next to it

Magnetic Field Immunity ISO 11452-8 (excluding Helmholtz coil method)

Exclusion. Written next to it on line 2 of A2LA certificate 4114.01.

ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
Other standards6
ANSI C63.10
ANSI C63.26
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national

National versions in the same scope

AS/NZS 62368.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

4114.01

The scope document we hold says it is valid until 2027-08-31.

View scope

Accredited scope, certificate 4114.01

LineMethodMatrixRange
1CISPR 11:2015+AMD1:2016+AMD2:2019; CISPR 14-1; CISPR 14-1:2016; CISPR 32; IEC 61000-3-2; IEC 61000-3-2:2005+AMD1:2008+AMD2:2009; IEC 61000-3-3; IEC 61000-4-2; IEC 61000-4-2:2008; IEC 61000-4-3; IEC 61000-4-3:2006+AMD1:2007+AMD2:2010; IEC 61000-4-4; IEC 61000-4-5:2014+AMD1:2017; IEC 61000-4-6; IEC 61000-4-6:2013; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-4-11:2004+AMD1:2017; IEC 61000-4-39-to 40 GHz
2CISPR 25; ISO 10605; ISO 11452-2; ISO 11452-9; ISO 11452-8; ISO 11452-4; ISO 7637-2:2004; ISO 7637-2; ISO 7637-3; ECE Regulation No.10 (Annex 7, 8, 9 (Appendix 3, 4), 10); IEC/EN 60601-1-2; EN 62368-1:2014+A11:2017; EN IEC 62368-1:2020+A11:2020; EN IEC 62368-1:2024+A11:2024; IEC 62368-1:2014; IEC 62368-1:2018; IEC 62368-1:2023; AS/NZS 62368.1:2018; AS/NZS 62368.1:2022; ISO 527; ISO 178; ISO 179; ISO 180; ISO 8256--
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4114.01) Revised 10/21/2025 Page 3 of 6 Test Technology: Test Method(s) 1, 2, 3: Measurement, Control, and Laboratory Equipment IEC/EN 61010-1; IEC 61010-1:2010+AMD1:2016; EN 61010-1:2010+A1:2019; IEC/EN 61010-2-010; IEC/EN 61010-2-020; IEC/EN 61010-2-051; IEC/EN 61010-2-081; IEC/EN 61010-2-101; IEC/EN 61010-2-201 Medical Equipment IEC/EN 60601-1; IEC 60601-1:2005+AMD1:2012+AMD2:2020; EN 60601-1:2006+A1:2013+A2:2021; IEC/EN 60601-1-3; IEC 60601-1-3:2008+AMD1:2013+AMD2:2021; EN 60601-1-3:2008+A1:2013+A2:2021; IEC/EN 60601-1-6; IEC 60601-1-6:2010+AMD1:2013+AMD2:2020; EN 60601-1-6:2010+A1:2015+A2:2021; IEC/EN 60601-1-8; IEC 60601-1-8:2006+AMD1:2012+AMD2:2020; EN 60601-1-8:2007+A1:2013+A2:2021; IEC/EN 60601-1-10; IEC 60601-1-10:2013; IEC/EN 60601-1-11; IEC 60601-1-11:2015+AMD1:2020; EN 60601-1-11:2015+A1:2021; IEC/EN 60601-2-2; IEC/EN 60601-2-4; IEC/EN 60601-2-5; IEC/EN 60601-2-10; IEC 60601-2-10:2012+AMD1:2016+AMD2:2023; EN 60601-2-10:2015+A1:2016+A2:2024; IEC/EN 60601-2-18; IEC/EN 60601-2-22; IEC/EN 60601-2-23; IEC/EN 60601-2-24; IEC/EN 60601-2-25; IEC/EN 60601-2-27; IEC/EN 60601-2-28; IEC/EN 60601-2-34; IEC/EN 60601-2-35; IEC/EN 60601-2-36; IEC/EN 60601-2-37; IEC/EN 60601-2-40; IEC 60601-2-43; IEC/EN 60601-2-44; IEC/EN 60601-2-45; IEC 60601-2-45:2011+AMD1:2015+AMD2:2022; EN 60601-2-45:2011+A1:2015+A2:2024; IEC/EN 60601-2-47; IEC/EN 60601-2-50; IEC 60601-2-50:2016; IEC/EN 60601-2-52; IEC/EN 60601-2-54; IEC/EN 60601-2-57; IEC/EN 60601-2-62; IEC/EN 60601-2-63; IEC 60601-2-63:2012+AMD1:2017+AMD2:2021; EN 60601-2-63:2015+A1:2019+A2:2021; IEC/EN 60601-2-65; IEC 60601-2-65:2012+AMD1:2017+AMD2:2021
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4114.01) Revised 10/21/2025 Page 4 of 6 Test Technology: Test Method(s) 1, 2, 3: Medical Equipment (continued) EN 60601-2-65:2013+A1:2020+A2:2021; IEC/EN 60601-2-66; IEC/EN 60601-2-83; IEC/EN 62366; IEC/EN 62366-1; IEC 62366-1:2015+AMD1:2020; EN 62366-1:2015+A1:2020; IEC/EN 80601-2-26; IEC/EN 80601-2-30; IEC/EN 80601-2-49; ISO 80601-2-56; ISO 80601-2-56:2017+AMD1:2018; EN ISO 80601-2-56; EN ISO 80601-2-56:2017+A1:2020; IEC/EN 80601-2-60; ISO 80601-2-61; EN ISO 80601-2-61; IEC 80601-2-77; EN IEC 80601-2-77; IEC 80601-2-78; EN IEC 80601-2-78 Specific Absorption Rate (SAR) / RF Exposure / Nerve Stimulation ARIB STD-T56; EN 50360; EN 50361; EN 50371; EN 50383; EN 50385; EN 50566; EN 50663; EN 62209-1; EN 62209-2; EN 62209-3; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; EN 62232; EN 62311; EN 62479; IEC 62209-2; EN IEC/IEEE 63195-1; IEC/IEEE 63195-1; IEEE Std 1528:2013; ACMA Radio Communications; ARPANSA Radiation Protection Standard; ASNZS 2772.2; 1999/519/EC; IEC PAS 63083 Hearing Aid Compatibility (HAC) 47 CFR, FCC Part 20 (using ANSI C63.19-2011 or ANSI C63.19-2019); TIA-5050; CTIA HAC Test Plan Telecommunications Terminal Equipment ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 328; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 301 091-1; ETSI EN 301 893; ETSI EN 301 908-1; ETSI EN 301 908-14; ETSI EN 301 908-15; ETSI EN 302 264; ETSI EN 302 288; ETSI EN 302 567; ETSI EN 302 858; ETSI EN 303 360; ETSI EN 303 396; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 305 550-1; ETSI EN 305 550-2; ETSI EN 303 687 Unlicensed Radio – FCC CFR 47, FCC Part 15C (using ANSI C63.10:2013, ANSI C63.10:2020); CFR 47, FCC Part 15E (using ANSI C63.10:2013, ANSI C63.10:2020 and FCC KDB 905462 D02 (v02)); CFR 47, FCC Part 15F (using ANSI C63.10:2013, ANSI C63.10:2020); CFR 47, FCC Part 15H (using ANSI C63.10:2013, ANSI C63.10:2020) Licensed Radio – FCC CFR 47, FCC Part 20 (using ANSI C63.26:2015); CFR 47, FCC Part 22 (using ANSI C63.26:2015); CFR 47, FCC Part 24 (using ANSI C63.26:2015); CFR 47, FCC Part 25 (using ANSI C63.26:2015); CFR 47, FCC Part 27 (using ANSI C63.26:2015); CFR 47, FCC Part 30 (using ANSI C63.26:2015); CFR 47, FCC Part 74 (using ANSI C63.26:2015); CFR 47, FCC Part 90 (using ANSI C63.26:2015)
5CFR 47, FCC Part 95 (using ANSI C63.26:2015); CFR 47, FCC Part 96 (using ANSI C63.26:2015); CFR 47, FCC Part 97 (using ANSI C63.26:2015); CFR 47, FCC Part 101 (using ANSI C63.26:2015); ANSI C63.10-2013; ANSI C63.10-2020; KDB 905462 D02 (v02)-to 325000 MHz
6ANSI C63.26-2015; IEEE Std 1528-2013; ANSI C63.19-2011; ANSI C63.19-2019-to 325000 MHz
7

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited HCT CO., LTD. Icheon-Si, Gyeonggi-Do, South Korea for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the A2LA – R256 – Specific Requirements. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 11h day of August 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4114.01 Valid to August 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

74, Seoicheon-ro 578 Beon-gil, Majang-Myeon, Icheon-Si, Gyeonggi-Do, 17383, South Korea, Icheon-Si, Gyeonggi-Do, KR

37.28088, 127.44291

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.