CEDEA ANALYSES
Parc de la Haie Plouvier 336 rue de la Haie Plouvier, 59273, FRETIN, France
Visit website- Accredited standards
- 3
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
HSG 248- Annexe 2
NF X43-269
NF X 43-050 (2021)
Arrêté du 1er octobre 2019 modifié par l’arrêté du 26 décembre 2019; HSG 248 - Annexe 2; NF X43-050 (2021)
NF X 43-050 (2021); NF X 43-269 - Annexe K (2017)
Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-20.
Scope as published by COFRAC
3 lines
ISO/IEC 17025
Active1-7313
The scope document we hold says it is valid until 2028-01-31.
Accredited scope, certificate 1-7313
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NF EN ISO/IEC 17025 | ENVIRONNEMENT / AMIANTE | - |
| 2 | NF X 43-050 (2021); NF X 43-269 - Annexe K (2017) | Ambient air | - |
| 3 | Arrêté du 1er octobre 2019 modifié par l’arrêté du 26 décembre 2019; HSG 248 - Annexe 2; NF X43-050 (2021) | Matériaux et produits manufacturés susceptibles de contenir de l’amiante délibérément ajouté : • Plâtres • Cellulose • Ciment / Carbonates • Polymères • Hydrocarbonés | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Parc de la Haie Plouvier 336 rue de la Haie Plouvier, FRETIN, 59273, FR
50.55960, 3.13505
Open in MapsLabs with overlapping accredited scope in France
- FLASHLAB NORDLEZENNES · ~6 kmCOFRACShares 3 accredited methods and materialsHSG 248- Annexe 2NF X 43-050 (2021)Ambient air
- EUROFINS ANALYSES POUR LE BATIMENT NORDHENIN-BEAUMONT · ~21 kmCOFRACShares 3 accredited methods and materialsHSG 248- Annexe 2NF X 43-050 (2021)Ambient air
- EUROFINS ANALYSES POUR LE BATIMENT NORD-OUEST CEBATDUNKERQUE · ~75 kmCOFRACShares 3 accredited methods and materialsHSG 248- Annexe 2NF X 43-050 (2021)Ambient air
- LEPBI - LABORATOIRE D'EXPERTISE DES POLLUANTS DU BÂTIMENT ET DE L'INDUSTRIEROISSY CHARLES DE GAULLE · ~177 kmCOFRACShares 3 accredited methods and materialsHSG 248- Annexe 2NF X 43-050 (2021)Ambient air
- CEAPIC : CENTRE D'EXPERTISE ET D'ACCOMPAGNEMENT EN POLLUANTS DES INDUSTRIES ET DES CONSTRUCTIONSSOISY SOUS MONTMORENCY · ~185 kmCOFRACShares 3 accredited methods and materialsHSG 248- Annexe 2NF X 43-050 (2021)Ambient air
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.