Hahn Calibration Service
20575 N. William Ave., 60069, Lincolnshire, IL, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1383.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1383.01) 08/21/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
HAHN CALIBRATION SERVICE
20575 N. William Ave.
Lincolnshire, IL 60069
William B. Hahn Phone: 847 338 6533
CALIBRATION
Valid To: August 31, 2027 Certificate Number: 1383.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 5:
I. Dimensional
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Optical Comparators3 –
Linear Inch
Magnification
XY Squareness
Up to 12 in
(10 to 100) x
Up to 8 in
140 + 16L μin
280 + 18L μin
270 + 18L μin
Glass scales
Toolmakers and Video
Microscopes – Stage
Calibration
3
XY Squareness
Linear Inch
Up to 8 in
Up to 12 in
270 + 18L μin
140 + 16L μin
Glass scales
____________________________________________
1 This laboratory offers commercial field calibration service only. | to 12 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1383.01) 08/21/2025 Page 2 of 2
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.