Registers refreshed 2026-11-20.See refresh dates
Canada

BHD Instrumentation

Edmonton, Canada

Visit website
A2LA 5037.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
28
A2LA certificate
1
Sites in our directory
4
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 28 scope lines.

A2LA certificate 5037.01 · 28 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 2 of 27 Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage3 – Measure (1050 to 150 000) V (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 0.12 % + 0.07 V 6.0 μV/V + 0.31 μV 3.2 μV/V + 0.51 μV 3.1 μV/V + 2.8 μV 4.9 μV/V + 51 μV 5.1 μV/V + 670 μV High Voltage Inc. DVR- 150, Fluke 8508A Fluke 8508A DC Current3 – Generate Clamp-On Meters3 (0 to 120) µA (0.12 to 1.2) mA (1.2 to 12) mA (12 to 120) mA (0.12 to 1.2) A (1.2 to 3.1) A (3.1 to 12) A (3.1 to 12) A (16.5 to 550) A (550 to 1025) A 0.11 nA/µA + 5.5 nA 0.064 µA/mA + 0.017 µA 0.086 µA/mA + 0.076 µA 0.086 µA/mA + 0.76 µA 140 µA/A + 9.4 µA 290 µA/A + 150 µA 0.33 mA/A + 0.77 mA 0.55 mA/A + 4.3 mA 0.58 % + 0.21 A 0.60 % + 0.50 A Fluke 5550A Fluke 5550A & 5500/coil DC Current3 – Measure (0 to 10) µA (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A (10 to 30) A 23 nA/µA + 0.44 nA 0.0088 nA/µA + 0.41 nA 8.1 nA/mA + 4.1 nA 9.4 nA/mA + 41 nA 0.038 µA/mA + 1.1 µA 110 µA/A + 100 µA 0.19 mA/A + 0.41 mA 0.51 mA/A + 4.4 mA Fluke 8588A Resistance3 – Generate (0 to 12) Ω (12 to 120) Ω (0.12 to 1.2) kΩ (1.2 to 12) kΩ (12 to 120) kΩ (0.12 to 1.2) MΩ (1.2 to 12) MΩ (12 to 120) MΩ (120 to 1200) MΩ 0.032 mΩ/Ω + 0.79 mΩ 0.024 mΩ/Ω + 0.80 mΩ 0.022 Ω/kΩ + 0.0018 Ω 0.022 Ω/kΩ + 0.0018 Ω 0.022 Ω/kΩ + 0.0018 Ω 25 Ω/MΩ + 1.8 Ω 44 Ω/MΩ + 24 Ω 390 Ω/MΩ + 2 kΩ 4.6 kΩ/MΩ + 810 kΩ Fluke 5550A
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 3 of 27 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance3 – Generate (cont) Fixed Points3 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 0.000 042 kΩ 0.000 28 kΩ 0.0009 kΩ 0.000 057 MΩ 0.000 70 MΩ 0.045 MΩ 0.0016 MΩ 0.030 GΩ 0.97 GΩ 0.021 TΩ IET Labs VRS-100 Resistance3 – Measure (0 to 1) Ω (1 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 1.2 µΩ/Ω + 120 µΩ 3.6 µΩ/Ω + 120 µΩ 7.1 µΩ/Ω + 98 µΩ 7.6 µΩ/Ω + 480 µΩ 7.6 µΩ/Ω + 5 mΩ 7.8 µΩ/Ω + 48 mΩ 8.9 Ω/MΩ + 1.1 Ω 13 Ω/MΩ + 110 Ω 55 Ω/MΩ + 11 kΩ Fluke 8588A Electrical Simulation of Thermocouple – Generate & Measure3 Type E Type J Type K (-250 to -150) °C (-150 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C 0.0034 °C/°C + 0.16 °C 0.000 88 °C/°C + 0.21 °C 0.0012 °C/°C + 0.24 °C 0.000 04 °C/°C + 0.22 °C 0.000 04 °C/°C + 0.22 °C 0.0026 °C/°C + 0.14 °C 0.0008 °C/°C + 0.17 °C 0.0017 °C/°C + 0.11 °C 0.000 03 °C/°C + 0.19 °C 0.000 005 °C/°C + 0.24 °C 0.0014 °C/°C + 0.19 °C 0.0012 °C/°C + 0.19 °C 0.0019 °C/°C + 0.12 °C 0.000 02 °C/°C + 0.28 °C 0.000 08 °C/°C + 0.30 °C Fluke 5550A
to 1 Ω
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 4 of 27 Parameter/Equipment Range CMC2, 5 (±) Comments Electrical Simulation of Thermocouple – Generate & Measure3 Type T (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.0012 °C/°C + 0.34 °C 0.0033 °C/°C + 0.21 °C 0.000 06 °C/°C + 0.22 °C 0.000 02 °C/°C + 0.11 °C Fluke 5550A Capacitance3 – Generate (0 to 1.2) nF (1.2 to 12) nF (12 to 120) nF (0.12 to 1.2) µF (1.2 to 12) µF (12 to 120) µF (0.12 to 1.2) mF (1.2 to 12) mF (12 to 120) mF 1.9 pF/nF + 2.8 pF 1.9 pF/nF + 7.8 pF 1.6 pF/nF + 39 pF 1.6 nF/µF + 0.39 nF 1.6 nF/µF + 3.9 nF 2.4 nF/µF + 39 nF 3.5 µF/mF + 0.39 µF 3.5 µF/mF + 3.9 µF 7.8 µF/mF + 39 µF Fluke 5550A Capacitance3 –Measure (0.1 to 1) nF (1.8 to 18) nF (18 to 180) nF (0.18 to 1.8) µF (1.8 to 18) µF (18 to 180) µF (0.18 to 1.8) mF (1.8 to 18) mF (18 to 120) mF 1.7 pF/nF + 1.9 pF 0.69 pF/nF + 3.6 pF 0.47 pF/nF + 18 pF 0.46 nF/µF + 0.20 nF 0.53 nF/µF + 1.7 nF 0.62 nF/µF + 18 nF 0.62 µF/mF + 0.18 µF 0.72 µF/mF + 1.8 µF 0.71 µF/mF + 13 µF Fluke 8588A Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (0 to 12) mV (3 to 5) Hz (5 to 10) Hz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300to 500) kHz 0.28 % + 6.3 µV 0.094 % + 6.3 µV 0.013 % + 5.5 µV 0.039 % + 5.5 µV 0.16 % + 14 µV 0.71 % + 28 µV 0.71 % + 28 µV Fluke 5550A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 5 of 27 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (cont) (12 to 120) mV (0.12 to 1.2) V (1.2 to 12) V (12 to 120) V (120 to 330) V (330 to 1020) V (3 to 5) Hz (5 to 10) Hz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300to 500) kHz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz (40 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300to 500) kHz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz (40 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz (40 to 20) kHz (20 to 50) kHz (50 to 100) kHz (3 to 5) Hz (5 to 10) Hz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (3 to 5) Hz (5 to 10) Hz (10 to 10) kHz 0.28 % + 6.3 µV 0.094 % + 6.3 µV 0.012 % + 5.5 µV 0.023 % + 7.0 µV 0.078 % + 19 µV 0.20 % + 28 µV 0.20 % + 28 µV 0.28 % + 0.071 mV 0.094 % + 0.066 mV 0.012 % + 0.066 mV 0.012 % + 0.0071 mV 0.025 % + 0.013 mV 0.055 % + 0.038 mV 0.16 % + 0.075 mV 0.16 % + 0.075 mV 0.28 % + 0.70 mV 0.094 % + 0.70 mV 0.012 % + 0.28 mV 0.012 % + 0.47 mV 0.025 % + 0.47 mV 0.055 % + 0.12 mV 0.20 % + 0.56 mV 0.20 % + 0.56 mV 0.28 % + 7.0 mV 0.094 % + 7.0 mV 0.012 % + 2.8 mV 0.012 % + 0.47 mV 0.028 % + 0.47 mV 0.070 % + 1.2 mV 0.28 % + 71 mV 0.093 % + 71 mV 0.015 % + 7.1 mV 0.024 % + 6.4 mV 0.17 % + 12 mV 0.28 % + 70 mV 0.094 % + 70 mV 0.021 % + 71 mV Fluke 5550A
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 6 of 27 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (1050 to 150 000) V (0 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (10 to 1000) V 60 Hz (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (0 to 2) kHz (2 to 10) kHz 1.1 % + 1 V 0.026 % + 1.2 μV 0.034 % + 1.2 μV 0.035 % + 1.2 μV 0.31 % + 0.78 μV 1.1 % + 3.4 μV 2.1 % + 3.4 μV 0.0073 % + 0.58 µV 0.012 % + 0.56 µV 0.022 % + 1.0 µV 0.053 % + 5.8 µV 0.21 % + 32 µV 0.99 % + 120 µV 0.0067 % + 5.4 µV 0.012 % + 5.6 µV 0.022 % + 10 µV 0.052 % + 59 µV 0.21 % + 320 µV 0.99 % + 1.2 mV 0.0067 % + 54 µV 0.012 % + 56 µV 0.022 % + 100 µV 0.052 % + 590 µV 0.21 % + 3.2 mV 1.1 % + 10 mV 0.0074 % + 570 µV 0.012 % + 560 µV 0.022 % + 1.0 mV 0.055 % + 5.6 mV 0.0095 % + 26 mV 0.0095 % + 26 mV High Voltage Inc. DVR-150, Fluke 8508A Fluke 8588A
1050 to 150000 V
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 7 of 27 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current3 – Generate (10 to 120) µA (0.12 to 1.2) mA (1.2 to 12) mA (12 to 120) mA (0.12 to 1.2) A (1.2 to 3.1) A (3.1 to 12) A (12 to 30.2) A (3 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz 0.078 % + 12 nA 0.078 % + 12 nA 0.078 % + 12 nA 0.39 % + 63 nA 0.39 % + 800 nA 0.059 % + 0.14 µA 0.078 % + 0.12 µA 0.078 % + 0.12 µA 0.24 % + 0.16 µA 0.39 % + 3.9 µA 0.063 % + 1.2 µA 0.063 % + 1.2 µA 0.063 % + 1.2 µA 0.14 % + 1.6 µA 0.39 % + 7.8 µA 0.063 % + 9.4 µA 0.039 % + 9.4 µA 0.063 % + 9.4 µA 0.12 % + 7.8 µA 0.39 % + 78 µA 0.062 % + 0.079 mA 0.047 % + 0.040 mA 0.062 % + 0.079 mA 0.20 % + 0.24 mA 0.39 % + 0.24 mA 0.094 % + 0.40 mA 0.070 % + 0.35 mA 0.094 % + 0.36 mA 0.47 % + 0.78 mA 0.12 % + 0.94 mA 0.094 % + 0.45 mA 0.12 % + 0.94 mA 0.47 % + 0.98 mA 0.079 % + 9.3 mA 0.055 % + 7.5 mA 0.40 % + 9.1 mA Fluke 5550A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 8 of 27 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current3 – Generate (cont) Clamp-On Meters: (16.5 to 149.999) A (150 to 1025) A (16.5 to 149.999) A (150 to 325.0) A (16.5 to 149.999) A (150 to 1025) A (16.5 to 149.999) A (150 to 350.0) A (45 to 65) Hz (45 to 65) Hz (65 to 440) Hz (65 to 440) Hz (45 to 65) Hz (45 to 65) Hz (65 to 440) Hz (65 to 440) Hz 0.64 % + 0.32 A 0.65 % + 1.1 A 1.2 % + 0.31 A 1.2 % + 1.1 A 0.28 % + 0.14 A 0.34 % + 0.11 A 0.88 % + 0.091 A 0.91 % + 0.14 A Fluke 5550A Non-toroidal Toroidal AC Current – Measure3 (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A (10 to 30) A (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (0 to 2) kHz (2 to 10) kHz (10 to 30) kHz (0 to 2) kHz (2 to 10) kHz (0 to 2) kHz (2 to 10) kHz 0.027 % + 5.2 nA 0.052 % + 5.2 nA 0.073 % + 5.2 nA 0.027 % + 51 nA 0.052 % + 51 nA 0.073 % + 51 nA 0.027 % + 510 nA 0.052 % + 510 nA 0.073 % + 510 nA 0.027 % + 5.1 µA 0.051 % + 5.1 µA 0.071 % + 5.1 µA 0.027 % + 100 µA 0.052 % + 100 µA 0.073 % + 100 µA 0.082 % + 0.50 mA 0.081 % + 0.51 mA 0.081 % + 13 mA 0.13 % + 12 mA Fluke 8588A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 9 of 27 Parameter/Range Frequency CMC2, 5 (±) Comments Inductance3 – Generate (13 to 120) µH (0.12 to 1.2) mH (1.2 to 12) mH (12 to 120) mH (0.12 to 1.2) H (1.2 to 12) H (12 to 120) H 1 kHz 1 kHz 110 Hz 100 Hz 10 Hz 3 Hz 2 Hz 0.019 nH/µH + 190 nH 1.6 µH/mH + 0.94 µH 1.6 µH/mH + 9.4 µH 1.6 µH/mH + 94 µH 2.0 mH/H + 0.94 mH 2.4 mH/H + 9.4 mH 3.2 mH/H + 94 mH Fluke 5550A III. Mechanical Parameter/Equipment Range CMC2, 5, 7 (±) Comments Pneumatic Pressure3 – Measuring Equipment (-15 to 15) kPa (10 to 250) kPa Up to 700 kPa Up to 7000 kPa Up to 20 000 kPa Up to 70 MPa 0.0053 % + 2.9 Pa 0.0065 % + 19 Pa 0.011 % + 0.026 kPa 0.0017 % + 0.63 kPa 0.0070 % + 1.1 kPa 0.0073 % + 3.6 kPa Fluke PM600-BG15K Fluke PM600-A350K Fluke 8370A with: PM600-A700 PM600-A7M PM600-A20M PM600-A70M Hydraulic Pressure3 – Measuring Equipment (1 to 112) MPa (5 to 280) MPa 0.0074 % + 240 Pa 0.0057 % + 490 Pa DHI PG7302-2 DHI PG7302-5 Parameter/Equipment Range CMC2, 5 (±) Comments Temperature3 – Measure (-60 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 600) °C 0.0011 °C/°C + 0.012 °C 0.000 05 °C/°C + 0.0012 °C 0.000 003 °C/°C + 0.0016 °C 0.000 014 °C/°C + 0.0013 °C AccuMac AM1880 Additel 286 Temperature3 – Measuring Equipment (-60 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 600) °C 0.0024 °C/°C + 0.060 °C 0.000 01 °C/°C + 0.060 °C 0.0 °C/°C + 0.30 °C 0.0006 °C/°C + 0.11 °C AccuMac AM1880 Additel 286
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 10 of 27 V. Time & Frequency Parameter/Equipment Frequency CMC2, 5 (±) Comments Frequency – Measuring Equipment (0.01 to 120) Hz (120 to 1200) Hz (1.2 to 12) kHz (12 to 120) kHz (120 to 1200) kHz (1.2 to 2) MHz 0.012 Hz + 5 µHz 0.12 Hz + 5 µHz 0.0012 kHz + 5 µHz 0.012 kHz + 5 µHz 0.12 kHz + 5 µHz 0.0012 MHz + 5 µHz Fluke 5522A ___________________________________________
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 11 of 27 SATELLITE FACILITY BHD INSTRUMENTATION LTD. 5050 106 Ave SE #132 Calgary, AB, CANADA T2C5E9 Garvin Stafford Phone: 780 434 7850 CALIBRATION I. Electrical – DC & Low Frequency Parameter/Equipment Range CMC2, 5, 7 (±) Comments DC Voltage3 – Generate (0 to 330) mV (0 to 3.3) V (0 to 33) V (30 to 330) V (100 to 1020) V 15 µV/V + 1.2 µV 7.1 µV/V + 8.4 µV 7.9 µV/V + 100 µV 13 µV/V + 1.5 mV 10 µV/V + 8.9 mV Fluke 5522A DC Voltage3 – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V 10 µV/V + 0.14 µV 12 µV/V + 0.36 µV 3.6 µV/V + 3.2 µV 6.4 µV/V + 31 µV 7.0 µV/V + 390 µV Fluke 8508A DC Current3 – Generate Clamp-On Meters 3 (0 to 330) μA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 20) A (16.5 to 550) A (550 to 1025) A 0.012 % + 0.02 µA 0.008 % + 0.04 µA 0.028 % + 3.5 µA 0.077 % + 2.5 µA 0.038 % + 140 µA 0.090 % + 700 µA 0.57 % + 0.25 A 0.60 % + 0.48 A Fluke 5522A DC Current3 – Measure (0 to 200) μA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A 13 µA/A + 0.000 33 µA 13 µA/A + 0.000 003 1 mA 21 µA/A + 0.000 031 mA 75 µA/A + 0.000 62 mA 0.026 % + 0.000 012 A 0.041 % + 0.000 31 A Fluke 8508A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 12 of 27 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Resistance3 – Generate Fixed Points 3 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 Ω to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 0.0032 % + 0.000 79 Ω 0.0020 % + 0.0012 Ω 0.0022 % + 0.0011 Ω 0.0022 % + 0.0015 Ω 0.0029 % + 0.0056 Ω 0.0025 % + 0.012 Ω 0.0024 % + 0.010 Ω 0.0022 % + 0.16 Ω 0.0026 % + 0.19 Ω 0.0028 % + 1.1 Ω 0.0019 % + 5.7 Ω 0.058 % + 0.98 kΩ 0.011 % + 0.21 kΩ 0.052 % + 5.0 kΩ 0.050 % + 7.8 kΩ 0.39 % + 140 kΩ 0.84 % + 0.86 MΩ 0.000 023 kΩ 0.000 22 kΩ 0.0022 kΩ 0.000 051 MΩ 0.000 83 MΩ 0.022 MΩ 0.0011 GΩ 0.031 GΩ 0.44 GΩ 0.021 TΩ Fluke 5522A IET Labs VRS- 100 Resistance3 – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (0.2 to 2) kΩ (2 to 20) kΩ (20 to 200) kΩ (0.2 to 2) MΩ (2 to 20) MΩ (20 to 200) MΩ (0.2 to 2) GΩ 50 µΩ/Ω + 3.9 µΩ 22 µΩ/Ω + 14 µΩ 11 µΩ/Ω + 47 µΩ 8.4 µΩ/Ω + 0.55 mΩ 8.0 µΩ/Ω + 5 mΩ 7.9 µΩ/Ω + 47 mΩ 15 µΩ/Ω + 1.0 Ω 11 µΩ/Ω + 90 Ω 0.023 % + 9.3 kΩ 0.24 % + 0.93 MΩ Fluke 8508A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 13 of 27 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Capacitance3 – Generate (220 to 400) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) μF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.23 % + 10 pF 0.19 % + 0.010 nF 0.28 % + 0.010 nF 0.17 % + 0.010 nF 0.081 % + 0.10 nF 0.17 % + 0.10 nF 0.17 % + 0.30 nF 0.17 % + 0.0010 µF 0.17 % + 0.0030 µF 0.17 % + 0.010 µF 0.30 % + 0.030 µF 0.33 % + 0.10 µF 0.33 % + 0.30 µF 0.40 % + 0.0010 mF 0.48 % + 0.0030 mF 0.41 % + 0.010 mF 0.59 % + 0.030 mF 0.87 % + 0.10 mF Fluke 5522A Electrical Simulation of Thermocouple 3 – Generate & Measure Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.25 °C 0.19 °C 0.21 °C 0.20 °C 0.23 °C 0.26 °C 0.20 °C 0.20 °C 0.21 °C 0.24 °C 0.30 °C 0.21 °C 0.68 °C 0.26 °C 0.36 °C 0.52 °C 0.25 °C 0.20 °C 0.19 °C Fluke 5522A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 14 of 27 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.060 % + 0.0060 mV 0.058 % + 0.0060 mV 0.009 % + 0.0060 mV 0.075 % + 0.0060 mV 0.28 % + 0.012 mV 0.61 % + 0.050 mV 0.028 % + 0.0080 mV 0.011 % + 0.0080 mV 0.012 % + 0.0080 mV 0.028 % + 0.0080 mV 0.064 % + 0.032 mV 0.15 % + 0.070 mV 0.035 % + 0.000 050 V 0.011 % + 0.000 060 V 0.016 % + 0.000 060 V 0.030 % + 0.000 050 V 0.081 % + 0.000 13 V 0.20 % + 0.000 60 V 0.034 % + 0.000 65 V 0.012 % + 0.000 60 V 0.018 % + 0.000 60 V 0.027 % + 0.000 60 V 0.069 % + 0.0016 V 0.017 % + 0.0020 V 0.017 % + 0.0060 V 0.023 % + 0.0060 V 0.023 % + 0.0060 V 0.10 % + 0.050 V 0.027 % + 0.010 V 0.019 % + 0.010 V 0.023 % + 0.010 V Fluke 5522A AC Voltage – Measure3 (20 to 200) mV (10 to 40) Hz (40 to 100) Hz (100 to 2000) Hz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 0.016 % + 0.014 mV 0.013 % + 0.0040 mV 0.010 % + 0.0020 mV 0.013 % + 0.0040 mV 0.034 % + 0.0080 mV 0.065 % + 0.020 mV Fluke 8508A
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 15 of 27 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Measure (cont) (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V (10 to 40) Hz (40 to 100) Hz (100 to 2000) Hz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (10 to 40) Hz (40 to 100) Hz (100 to 2000) Hz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (10 to 40) Hz (40 to 100) Hz (100 to 2000) Hz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (10 to 40) Hz (40 to 10 000) Hz (10 to 30) kHz (30 to 100) kHz 0.014 % + 0.000 12 V 0.011 % + 0.000 020 V 0.0085 % + 0.000 020 V 0.0071 % + 0.000 020 V 0.011 % + 0.000 020 V 0.050 % + 0.000 20 V 0.22 % + 0.0020 V 0.77 % + 0.020 V 0.014 % + 0.000 12 V 0.011 % + 0.000 020 V 0.0085 % + 0.000 020 V 0.0071 % + 0.000 020 V 0.011 % + 0.000 020 V 0.050 % + 0.000 20 V 0.22 % + 0.0020 V 0.77 % + 0.020 V 0.014 % + 0.012 V 0.010 % + 0.0020 V 0.0088 % + 0.0020 V 0.014 % + 0.0020 V 0.044 % + 0.004 V 0.069 % + 0.020 V 0.014 % + 0.070 V 0.014 % + 0.070 V 0.011 % + 0.020 V 0.049 % + 0.040 V 0.054 % + 0.20 V Fluke 8508A AC Current – Generate3 (29 to 330) μA (0.33 to 3.3) mA (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.16 % + 0.10 µA 0.11 % + 0.10 µA 0.094 % + 0.10 µA 0.25 % + 0.15 µA 0.61 % + 0.20 µA 1.2 % + 0.40 µA 0.17 % + 0.15 µA 0.096 % + 0.15 µA 0.077 % + 0.15 µA 0.15 % + 0.20 µA 0.39 % + 0.30 µA 0.77 % + 0.60 µA Fluke 5522A
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 16 of 27 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current – Generate (cont) (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 20) A Clamp-On Meters 3: (16.5 to 149.999) A (150 to 1025) A (16.5 to 149.999) A (150 to 325.0) A (16.5 to 149.999) A (150 to 1025) A (16.5 to 149.999) A (150 to 350.0) A (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (45 to 65) Hz (45 to 65) Hz (65 to 440) Hz (65 to 440) Hz (45 to 65) Hz (45 to 65) Hz (65 to 440) Hz (65 to 440) Hz 0.15 % + 2.0 µA 0.069 % + 2.0 µA 0.030 % + 2.0 µA 0.061 % + 2.0 µA 0.15 % + 3.0 µA 0.31 % + 4.0 µA 0.15 % + 2.0 µA 0.069 % + 2.0 µA 0.03 % + 2.0 µA 0.07 % + 50 µA 0.15 % + 100 µA 0.30 % + 200 µA 0.15 % + 100 µA 0.046 % + 100 µA 0.46 % + 1 mA 2.0 % + 5 mA 0.089 % + 5 mA 0.11 % + 5 mA 2.8 % + 5 mA 0.65 % + 0.31 A 0.65 % + 1.1 A 1.2 % + 0.31 A 1.2 % + 1.1 A 0.28 % + 0.13 A 0.33 % + 0.12 A 0.90 % + 0.69 A 0.92 % + 0.13 A Fluke 5522A Non-toroidal Toroidal
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 17 of 27 II. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Frequency – Measuring Equipment3 (1 to 120) Hz (120 to 1200) Hz (1.2 to 12) kHz (12 to 120) kHz (120 to 500) kHz 0.012 Hz + 5 µHz 0.12 Hz + 5 µHz 0.001 kHz + 5 µHz 0.012 kHz + 5 µHz 0.12 kHz + 5 µHz Fluke 5522A ___________________________________________________________________
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 18 of 27 SATELLITE FACILITY BHD INSTRUMENTATION LTD. 1120-22091 Fraserwood Way Richmond, BC, CANADA V6W 0A8 Alfredo Ayat Phone: 604 276 4585 CALIBRATION I. Dimensional Parameter/Equipment Range CMC2, 5 (±) Comments Length Standards3 (0.05 to 0.4) in (0.45 to 1) in (1 to 2) in (2 to 3) in (3 to 4) in 6.4 µin. (4.1 + 8.9L) µin (3.1 + 11L) µin (3.3 + 11L) µin (3.2 + 11L) µin Gauge blocks II. Electrical – DC & Low Frequency Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage3 – Generate (0 to 330) mV (0 to 3.3) V (0 to 33) V (30 to 330) V 100 to 1020) V 16 μV/V + 0.13 μV 9.0 μV/V + 2.4 μV 9.7 μV/V + 23 μV 14 μV/V + 170 μV 15 μV/V + 2.1 mV Fluke 5522A DC Voltage3 – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V 9.7 μV/V + 0.14 μV 4.0 μV/V + 0.36 μV 4.6 μV/V + 3.2 μV 5.7 μV/V + 31 μV 5.6 μV/V + 390 μV Fluke 8508A
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 19 of 27 Parameter/Equipment Range CMC2, 7 (±) Comments DC Current3 – Generate Clamp-On Meters (0 to 330) μA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (0 to 11) A (11 to 20) A (16.5 to 550) A (550 to 1025) A 0.012 % + 0.016 µA 0.0081 % + 0.045 µA 0.0084 % + 0.24 µA 0.0084 % + 2.6 µA 0.016 % + 39 µA 0.029 % + 62 µA 0.040 % + 430 µA 0.080 % + 1.0 mA 0.58 % + 200 mA 0.60 % + 480 mA Fluke 5522A DC Current3 – Measure (0 to 200) μA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A 16 μA/A + 0.000 33 μA 19 μA/A + 0.0031 μA 24 μA/A + 0.031 μA 55 μA/A + 0.62 μA 0.024 % + 12 μA 0.048 % + 310 μA Fluke 8508A Resistance3 – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ 0.0029 % + 0.89 mΩ 0.0023 % + 1.3 mΩ 0.0024 % + 1.2 mΩ 0.0025 % + 1.5 mΩ 0.0025 % + 1.6 mΩ 0.0025 % + 16 mΩ 0.0024 % + 19 mΩ 0.0025 % + 160 mΩ 0.0024 % + 180 mΩ 0.0030 % + 1.3 Ω 0.0026 % + 3.5 Ω 0.0048 % + 24 Ω 0.011 % + 29 Ω 0.018 % + 2.7 kΩ 0.046 % + 1.0 kΩ 0.23 % + 140 kΩ 1.3 % + 430 kΩ Fluke 5522A
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 20 of 27 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Resistance3 – Generate Fixed Points 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 0.000 030 kΩ 0.000 30 kΩ 0.0046 kΩ 0.000 040 MΩ 0.000 51 MΩ 0.021 MΩ 0.0032 MΩ 0.021 GΩ 0.37 GΩ 0.019 TΩ IET Labs VRS-100 Resistance3 – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (0.2 to 2) kΩ (2 to 20) kΩ (20 to 200) kΩ (0.2 to 2) MΩ (2 to 20) MΩ (20 to 200) MΩ (0.2 to 2) GΩ 20 μΩ/Ω + 3.9 μΩ 11 μΩ/Ω + 14 μΩ 8.3 μΩ/Ω + 47 μΩ 7.9 μΩ/Ω + 550 μΩ 8.1 μΩ/Ω + 5 mΩ 7.8 μΩ/Ω + 47 mΩ 10 μΩ/Ω + 1.0 Ω 26 μΩ/Ω + 90 Ω 0.014 % + 9.3 kΩ 0.16 % + 0.93 MΩ Fluke 8508A Capacitance3 – Generate (220 to 400) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) μF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.39 % + 8.0 pF 0.36 % + 0.0081 nF 0.37 % + 0.009 nF 0.20 % + 0.0086 nF 0.20 % + 0.010 nF 0.20 % + 0.010 nF 0.20 % + 0.025 nF 0.19 % + 1.0 nF 0.20 % + 2.6 nF 0.21 % + 8.2 nF 0.32 % + 25 nF 0.39 % + 82 nF 0.37 % + 290 nF 0.37 % + 0.9 µF 0.53 % + 0.6 µF 0.36 % + 13 µF 0.55 % + 50 µF 0.94 % + 72 µF Fluke 5522A
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 21 of 27 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple3 – Generate & Measure Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C 0.22 °C 0.14 °C 0.12 °C 0.15 °C 0.19 °C 0.26 °C 0.15 °C 0.13 °C 0.21 °C 0.32 °C 0.49 °C 0.19 °C 0.13 °C 0.12 °C Fluke 5522A Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (1 to 33) mV (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.062 % + 0.0052 mV 0.012 % + 0.0052 mV 0.015 % + 0.0057 mV 0.073 % + 0.0068 mV 0.27 % + 0.013 mV 0.58 % + 0.059 mV Fluke 5522A
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 22 of 27 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (cont) (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.045 to 1) kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.023 % + 0.0084 mV 0.011 % + 0.0093 mV 0.011 % + 0.013 mV 0.026 % + 0.014 mV 0.061 % + 0.030 mV 0.15 % + 0.083 mV 0.024 % + 0.042 mV 0.012 % + 0.050 mV 0.015 % + 0.078 mV 0.022 % + 0.096 mV 0.053 % + 0.17 mV 0.18 % + 0.85 mV 0.024 % + 0.56 mV 0.012 % + 0.52 mV 0.018 % + 0.81 mV 0.026 % + 1.3 mV 0.068 % + 2.3 mV 0.015 % + 2.3 mV 0.015 % + 9.4 mV 0.019 % + 9.7 mV 0.024 % + 8.9 mV 0.15 % + 68 mV 0.024 % + 13 mV 0.020 % + 15 mV 0.024 % + 12 mV Fluke 5522A AC Voltage3 – Measure (20 to 200) mV (10 to 40) Hz (40 to 100) Hz (100 to 2000) Hz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 0.015 % + 0.014 mV 0.013 % + 0.0040 mV 0.010 % + 0.0020 mV 0.013 % + 0.0040 mV 0.032 % + 0.008 mV 0.065 % + 0.020 mV Fluke 8508A
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 23 of 27 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Measure (cont) (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V 1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (100 to 2000) Hz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (100 to 2000) Hz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (100 to 2000) Hz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (10 to 40) Hz (40 to 10 000) Hz (10 to 30) kHz (30 to 100) kHz 0.014 % + 0.000 12 V 0.010 % + 0.000 020 V 0.0085 % + 0.000 020 V 0.0069 % + 0.000 020 V 0.011 % + 0.000 020 V 0.020 % + 0.000 40 V 0.049 % + 0.0020 V 0.32 % + 0.0020 V 0.68 % + 0.020 V 0.014 % + 0.0012 V 0.011 % + 0.000 020 V 0.0088 % + 0.000 020 V 0.0068 % + 0.000 020 V 0.010 % + 0.000 020 V 0.032 % + 0.000 40 V 0.090 % + 0.0020 V 0.55 % + 0.020 V 2.1 % + 0.20 V 0.015 % + 0.012 V 0.013 % + 0.0020 V 0.011 % + 0.0020 V 0.0086 % + 0.0020 V 0.010 % + 0.0020 V 0.027 % + 0.000 40 V 0.078 % + 0.020 V 0.014 % + 0.070 V 0.011 % + 0.020 V 0.011 % + 0.020 V 0.057 % + 0.040 V 0.054 % + 0.20 V Fluke 8508A AC Current3 – Generate (29 to 330) μA (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.13 % + 0.091 µA 0.09 % + 0.093 µA 0.071 % + 0.092 µA 0.21 % + 0.16 µA 0.58 % + 0.19 µA 1.2 % + 0.84 µA Fluke 5522A
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 24 of 27 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Generate (cont) (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (100 to 1000) Hz (1 to 5) kHz (45 to 100) Hz (100 to 1000) Hz (1 to 5) kHz 0.16 % + 0.14 µA 0.093 % + 0.15 µA 0.074 % + 0.15 µA 0.15 % + 0.24 µA 0.38 % + 0.27 µA 0.76 % + 0.70 µA 0.14 % + 1.9 µA 0.064 % + 2.0 µA 0.026 % + 2.2 µA 0.057 % + 2.1 µA 0.15 % + 2.7 µA 0.31 % + 3.5 µA 0.14 % + 21 µA 0.064 % + 21 µA 0.025 % + 24 µA 0.065 % + 46 µA 0.013 % + 88 µA 0.026 % + 180 µA 0.14 % + 0.11 mA 0.046 % + 0.13 mA 0.49 % + 0.80 mA 2.0 % + 3.9 mA 0.047 % + 1.7 mA 0.078 % + 1.7 mA 2.4 % + 1.5 mA 0.085 % + 7.4 mA 0.11 % + 8.0 mA 2.4 % + 5.2 mA Fluke 5522A AC Current3 – Measure (20 to 200) μA (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 0.026 % + 0.024 µA 0.059 % + 0.024 µA 0.057 % + 0.024 µA 0.30 % + 0.024 µA Fluke 8508A
25

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 25 of 27 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Measure (cont) (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 20 kHz (20 to 100) kHz 0.026 % + 0.000 24 mA 0.032 % + 0.000 24 mA 0.057 % + 0.000 24 mA 0.30 % + 0.000 24 mA 0.026 % + 0.0024 mA 0.024 % + 0.0024 mA 0.057 % + 0.0024 mA 0.30 % + 0.0024 mA 0.026 % + 0.024 mA 0.025 % + 0.024 mA 0.052 % + 0.024 mA 0.052 % + 0.000 24 A 0.091 % + 0.000 24 A 0.23 % + 0.000 24 A 0.100 % + 0.0024 A 0.31 % + 0.0024 A Fluke 5522A III. Mechanical Parameter/Equipment Range CMC2, 5, 7 (±) Comments Pneumatic Gage Pressure3 – Measuring Equipment (0 to 250) kPa 250 kPa to 7 MPa 0.012 % + 8 Pa 0.011 % + 0.26 kPa DHDHI PPC4 Hydraulic Gage Pressure3 – Measuring Equipment (10 to 3000) psi (100 to 15 000) psi 0.0082 % + 0.17 PSI 0.012 % + 0.59 PSI Fluke Q-RPT A20M Fluke Q-RPT A100MI Torque Transducers3 (100 to 1000) lbf·ft 0.99 % Norbar 21426 Norbar 43228
26

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 26 of 27 IV. Thermodynamics Parameter/Equipment Range CMC2, 4, 5 (±) Comments Temperature3 – Measure (-30 to -0) °C (0 to 50) °C (50 to 420) °C (420 to 600) °C 0.006 °C/°C + 0.015 °C 0.000 080 °C/°C + 0.015 °C 0.000 030 °C/°C + 0.016 °C 0.067 °C SPRT, Fluke 1586A Temperature3 – Measuring Equipment (-30 to -0) °C (0 to 50) °C (50 to 420) °C (420 to 600) °C 0.0025 °C/°C + 0.03 °C 0.0011 °C/°C + 0.03 °C 0.000 89 °C/°C + 0.04 °C 0.60 °C SPRT, Fluke 1586A VI. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Frequency3 – Measuring Equipment (10 to 120) Hz (120 to 1200) Hz (1.2 to 12) kHz (12 to 120) kHz (120 to 1200) kHz (1.2 to 2) MHz 12 mHz 120 mHz 1.2 Hz 12 Hz 120 Hz 1.2 kHz Fluke 5522A ___________________________________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due t o the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field and mobile calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncer tainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
27

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5037.01) Revised 1/22/2025 Page 27 of 27 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 L is the numerical value of the nominal length of the device measured in inches, 7 In the statement of CMC, percentages are to be read as percent of indicated value. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
28ISO/IEC 17025:20 17; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

3 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.