TECNIPRECISIÓN CIA. LTDA.

Av. Galo Plaza Lasso N65-95 y Bellavista, Pichincha - Quito, Ecuador, Pichincha - Quito, Ecuador

Visit website
A2LA 7429.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
1
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ISO 4787Laboratory glass and plastic ware - Volumetric instruments - Methods for testing of capacity and for use

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

7429.01

The scope document we hold says it is valid until 2027-04-30.

View scope

Accredited scope, certificate 7429.01

LineMethodMatrixRange
1ISO/IEC 17025:2017--
2NTE INEN-ISO 4787-See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7429.01) 05/29/2025 Page 3 of 4 IV. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Pressure – Measuring Equipment Up to 2.07 MPa (2.07 to 3.57) MPa (3.57 to 7) MPa (7 to 35) MPa (35 to 70) MPa 2.3E-04 MPa 3.9E-04 MPa 8.1E-04 MPa 4.1E-03 MPa 8.0E-03 MPa Comparison with deadweight tester Scales & Balances3 Class: I Class: II Up to 30 g (30 to 100) g (100 to 220) g (220 to 500) g (500 to 600) g Up to 100 g (100 to 500) g (500 to 1000) g (1000 to 5000) g (5000 to 10 000) g 0.61 mg 1.0 mg 1.8 mg 2.1 mg 2.5 mg 2.9 mg 6.7 mg 14 mg 96 mg 130 mg OIML class E2 & F1 weights V. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Environmental Thermometers (10 to 20) °C (20 to 50) °C 0.22 °C 0.31 °C Temperature sensor & readout Relative Humidity – Thermo-Hygrometer (20 to 50) % RH (50 to 80) % RH 1.7 % RH 1.9 % RH Humidity sensor & readout IR Thermometers (Fixed Emissivity of 0.95) Up to 50 °C (50 to 250) °C (250 to 500) °C 0.13 °C 0.48 °C 1.2 °C Blackbody (8 to 14) µm spectral band & emissivity of 0.95 Bi-Metal Thermometers³ (-25 to 50) °C (50 to 300) °C (300 to 600) °C 0.29 °C 0.57 °C 1.4 °C Dry-well (dry-block)
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7429.01) 05/29/2025 Page 4 of 4 Parameter/Equipment Range CMC2 (±) Comments Digital Thermometers (TC or RTD Probes & Indicators)³ (-25 to 0) °C (0 to 150) °C (150 to 200) °C (200 to 400) °C (400 to 600) °C 0.028 °C 0.028 °C 0.046 °C 0.054 °C 0.066 °C PRT probe & precision multimeter, dry-well (dry-block) VI. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Photo Tachometers Up to 600 RPM (600 to 3000) RPM (3000 to 9000) RPM (9000 to 60 000) RPM (60 000 to 90 000) RPM 0.18 RPM 0.62 RPM 0.70 RPM 2.5 RPM 3.6 RPM Multifunction calibrator comparison & LED artifact _________________________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards of nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
5ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Av. Galo Plaza Lasso N65-95 y Bellavista, Pichincha - Quito, Ecuador, Pichincha - Quito, EC

-0.13828, -78.46777

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.