Registers refreshed 2026-11-08.See refresh dates
Netherlands

Signify Netherlands

Flight Forum 2000, 5657 EX, EINDHOVEN, Netherlands

RvA L315ISO/IEC 17025Register refreshed 2026-11-08

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
14
RvA certificate
1
Site in our directory
1
RvA accredited scope

What this lab is accredited for

Our reading of the RvA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 14 standard numbers and the 14 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series7
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

Certificate says EN 61000-4-6. Probably the same standard; not checked against the EN document.

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

Certificate says EN IEC 55015, IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

Other standards3
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
FCC PART 15Radio Frequency Devices
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests

Read from the RvA scope document we downloaded on 2026-02-12. Register refreshed 2026-11-08.

Scope as published by RvA

6 lines
RvA

ISO/IEC 17025

Active

L315

The scope document we hold says it is valid until 2027-04-01.

View scope

Accredited scope, certificate L315

LineMethodMatrixRange
1EN 55032, CISPR 32, EN IEC 55015, CISPR 15Multi-Media Equipment, Electrical lighting and similar equipmentSee scope document
2EN 55022, CISPR 22, EN IEC 55015, CISPR 15, EN 55032, CISPR 32, EN 55011, CISPR 11, FCC 47 CFR Part 15B, ANSI C63.4:2014Information technology equipment, Electrical lighting and similar equipment, Multi-Media Equipment, Industrial, scientific and medical (ISM) radio-frequency equipment, Radio Frequency Devices: unintentional radiatorsSee scope document
3EN ISO/IEC 17025:2017; EN IEC 55015; CISPR 15; EN 55032; CISPR 32; EN 55022; CISPR 22; FCC 47 CFR Part 15B; ANSI C63.4:2014Electrical lighting and similar equipment; Multi-Media Equipment; Information technology equipment; Industrial, scientific and medical (ISM) radio-frequency equipmentSee scope document
4EN IEC 55015Electrical lighting and similar equipmentSee scope document
5EN ISO/IEC 17025:2017; EN 61000-4-6; IEC 61000-4-6; EN IEC 61000-4-3; IEC 61000-4-3; EN 60601-1-2; IEC 60601-1-2; EN 61000-4-2; IEC 61000-4-2; EN 61000-4-4; IEC 61000-4-4; EN 61000-4-5; IEC 61000-4-5; EN 61000-4-8; IEC 61000-4-8; EN IEC 61000-4-11; IEC 61000-4-11; ETSI EN 300 328Electrical and electronic equipment1 to 10 Vrms
6ETSI EN 300 328transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques2.4 to 2.4835 GHz

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Flight Forum 2000, EINDHOVEN, 5657 EX, NL

51.44639, 5.40000

Open in Maps

Labs with overlapping accredited scope in Netherlands

Accreditation data refreshed from the RvA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the RvA entry linked above.