BI-LAB S.r.l.
Via Alfio Flores 15, 00053, Civitavecchia, Italy
Visit website- Accredited standards
- 9
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
APAT CNR IRSA 2100 Man 29 2003
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2100 Man 29 2003; UNI EN 14792:2017; UNI EN 15058:2017; UNI EN 14789:2017; UNI EN 14790:2017; UNI EN ISO 16911-1:2013
UNI EN 14181:2015; UNI EN 13284-1:2017; UNI EN 14791:2017; DLgs n 152 03/04/2006 GU n 88 14/04/2006 Parte V all VI par 4.4
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active01083
Accredited scope, certificate 01083
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI EN 14181:2015; UNI EN 13284-1:2017; UNI EN 14791:2017; DLgs n 152 03/04/2006 GU n 88 14/04/2006 Parte V all VI par 4.4 | Stationary source emissions | 5 to 2000 mg/m3 |
| 2 | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2100 Man 29 2003; UNI EN 14792:2017; UNI EN 15058:2017; UNI EN 14789:2017; UNI EN 14790:2017; UNI EN ISO 16911-1:2013 | Waste water | 0 to 1300 mg/m3 come NO2 |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- AGRI-BIO-ECO Laboratori RiunitiPomezia · ~82 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003UNI EN 14791:2017Stationary source emissions
- ECOPOINTAvezzano · ~137 kmACCREDIAShares 3 accredited methods and materialsUNI EN 14791:2017Stationary source emissionsWaste water
- LabAnalysis Environmental ScienceSan Giovanni Teatino · ~202 kmACCREDIAShares 3 accredited methods and materialsUNI EN 14791:2017Stationary source emissionsWaste water
- Gruppo C.S.A.Rimini · ~223 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003Stationary source emissionsWaste water
- ALFA SolutionsReggio Emilia · ~301 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003Stationary source emissionsWaste water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.