SIMCO Electronics - Memphis
7730B Trinity Road, Suite 130, 38018, Cordova, TN, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 1395.21 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.21) 07/29/2025 Page 2 of 5
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Current – Measure
(10 to 100) μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
25 μA/A + 0.8 nA
25 μA/A + 5 nA
25 μA/A + 50 nA
42 μA/A + 0.5 μA
0.016 % + 10 μA
HP 3485A OPT-2
Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.11 to 1.1) GΩ
180 μΩ/Ω + 1 mΩ
63 μΩ/Ω + 1.5 mΩ
30 μΩ/Ω + 1.4 mΩ
26 μΩ/Ω + 2 mΩ
29 μΩ/Ω + 2 mΩ
26 μΩ/Ω + 0.02 Ω
26 μΩ/Ω + 0.02 Ω
27 μΩ/Ω + 0.2 Ω
26 μΩ/Ω + 0.2 Ω
41 μΩ/Ω + 2 Ω
34 μΩ/Ω + 2 Ω
49 μΩ/Ω + 30 Ω
0.013 % + 50 Ω
0.022 % + 2.5 kΩ
0.052 % + 3 kΩ
0.23 % + 0.1 MΩ
1.3 % + 0.5 MΩ
Fluke
5522A/SC1100
Resistance – Measure
10 mΩ to 10 Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
0.017 % + 1 mΩ
15 μΩ/Ω + 1.4 mΩ
12 μΩ/Ω + 2.0 mΩ
12 μΩ/Ω + 20 mΩ
12 μΩ/Ω + 0.2 Ω
19 μΩ/Ω + 2.0 Ω
63 μΩ/Ω + 50 Ω
0.06 % + 3 kΩ
HP 3458A OPT-2 | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.21) 07/29/2025 Page 3 of 5
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Generate
(30 to 330) μA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 11) A
(11 to 20) A
(30 to 330) μA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 11) A
(11 to 20) A
@ 1 kHz
@ 5 kHz
0.12 % + 0.1 μA
0.079 % + 0.15 μA
0.033 % + 2 μA
0.035 % + 20 μA
0.040 % + 100 μA
0.040 % + 2 mA
0.12 % + 5 mA
0.24 % + 0.1 μA
0.16 % + 0.15 μA
0.064 % + 2 μA
0.079 % + 20 μA
0.47 % + 100 μA
0.25 % + 2 mA
2.4 % + 5 mA
Fluke
5522A/SC1100
AC Current – Measure
(5 to 100) μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
@ 1kHz
0.07 % + 0.03 μA
0.036 % + 0.2 μA
0.036 % + 2 μA
0.036 % + 20 μA
0.12 % + 0.2 mA
HP 3458A OPT-2
AC Voltage – Generate
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
0.063 % + 6 μV
0.017 % + 6 μV
0.02 % + 6 μV
0.08 % + 6 μV
0.28 % + 12 μV
0.63 % + 50 μV
0.024 % + 8 μV
0.012 % + 8 μV
0.013 % + 8 μV
0.028 % + 8 μV
0.063 % + 32 μV
0.16 % + 70 μV
0.023 % + 50 μV
0.012 % + 60 μV
0.015 % + 60 μV
0.024 % + 50 μV
0.055 % + 0.13 mV
0.19 % + 0.60 mV
Fluke
5522A/SC1100 | 30 to 20 A |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.21) 07/29/2025 Page 4 of 5
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(cont)
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.023 % + 0.65 mV
0.012 % + 0.6 mV
0.019 % + 0.6 mV
0.028 % + 0.6 mV
0.070 % + 1.6 mV
0.015 % + 2 mV
0.016 % + 6 mV
0.02 % + 6 mV
0.02 % + 6 mV
0.18 % + 50 mV
0.024 % + 10 mV
0.020 % + 10 mV
0.024 % + 10 mV
Fluke
5522A/SC1100
AC Voltage – Measure
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 700) V
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
(100 to 300) kHz
(300 to 1000) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
(100 to 300) kHz
(300 to 1000) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
(100 to 300) kHz
(300 to 1000) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
40 Hz to 1 kHz
0.0095 % + 2 μV
0.018 % + 2 μV
0.099 % + 2 μV
0.11 % + 2 μV
0.11 % + 2 μV
0.009 % + 20 μV
0.017 % + 20 μV
0.093 % + 20 μV
0.093 % + 20 μV
0.093 % + 20 μV
0.010 % + 0.4 mV
0.010 % + 0.2 mV
0.017 % + 0.2 mV
0.093 % + 0.2 mV
0.093 % + 0.2 mV
0.093 % + 0.2 mV
0.024 % + 2 mV
0.025 % + 2 mV
0.14 % + 2 mV
0.047 % + 20 mV
HP 3458A OPT-2
____________________________________________
1 This laboratory offers commercial service. | to 1020 V |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.21) 07/29/2025 Page 5 of 5
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The measurands stated are generated using the indicated instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges indicated.
CMCs are expressed as either a specific value th at covers the full range or as a percent/fraction of the
reading plus a fixed floor specification.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 6 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- MSI-Viking GageCanton, MI · ~284 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- K & S AssociatesNashville, TN · ~293 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - MADISONMadison, AL · ~295 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - JACKSONJackson, MS · ~320 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Co., LLC - LEBANONLebanon, TN · ~336 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.