Trescal, Inc. - Airbus, AL

320 Airbus Way, 36607, Mobile, AL, United States

Visit website
A2LA 2516.03ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
12
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 2516.03 · 12 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-0.14 to 4.9 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 2 of 11 Parameter/Equipment Range CMC2 (±) Comments Dial & Digital Indicators Up to 1 in 9.5 µin + 3 µin/in Gage blocks Height Gages (1 to 48) in 290 µin + 5.7 µin/in Gage blocks, surface plate Depth Gages Up to 48 in 35 µin + 9.5 µin/in Gage blocks, surface plate Calipers Outside, Step & Depth Inside Up to 48 in 1.5 in 33 µin + 7.7 µin/in 45 µin Gage blocks, surface plate Ring gages II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate3, 7 (0 to 329.999) mV (0 to 3.299 999) V (0 to 32.999 99) V (30 to 329.9999) V (100 to 1000) V 2.4 µV + 47 nV/mV 18 µV + 35 µV/V 95 µV + 38 µV/V 1.7 mV + 43 µV/V 5.5 mV + 43 µV/V Fluke 5500A DC Voltage – Measure3, 7 Up to 100 mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 3.5 µV + 38 nV/mV 9.8 µV + 25 µV/V 77 µV + 24 µV/V 1.1 mV + 45 µV/V 14 mV + 42 µV/V Tektronix 4050 DC Current – Generate3, 7 (0 to 3.299 99) mA (0 to 32.9999) mA (0 to 329.999) mA (0 to 2.199 99) A (0 to 11) A (10 to 16.5) A (16.5 to 150) A (150 to 550) A 39 nA + 0.1 µA/mA 0.2 µA + 79 nA/mA 2.6 µA + 82 nA/mA 35 µA + 0.24 mA/A 0.38 mA + 0.46 mA/A 50 mA + 3.3 mA/A 0.18 A + 3.4 mA/A 0.84 A + 3.4 mA/A Fluke 5500A Fluke 5500A w/ coil
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 3 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current – Measure3, 7 (3 to 10) A 25 nA + 0.51 nA/µA 0.1 µA + 0.52 µA/mA 2.5 µA + 0.51 µA/mA 10 µA + 0.52 µA/mA 0.25 mA + 0.53 mA/A 1.6 mA + 1 mA/A 5.3 mA + 1.6 mA/A Tektronix 4050 Resistance – Generate3, 7 Up to 10.9999 Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.999) kΩ (110 to 329.999) kΩ (0.33 to 1.099 99) MΩ (1.1 to 3.299 00) MΩ (3.3 to 10.9999) MΩ (11 to 32.9999) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ 4.8 mΩ + 96 µΩ/Ω 8.8 mΩ + 94 µΩ/Ω 10 mΩ + 70 µΩ/Ω 16 mΩ + 70 µΩ/Ω 70 mΩ + 71 µΩ/Ω 0.12 Ω + 70 µΩ/Ω 0.7 Ω + 71 µΩ/Ω 1.2 Ω + 70 µΩ/Ω 7.5 Ω + 92 µΩ/Ω 15 Ω + 94 µΩ/Ω 82 Ω + 0.22 mΩ/Ω 0.25 kΩ + 0.12 mΩ/Ω 2 kΩ + 0.47 mΩ/Ω 12 kΩ + 0.92 mΩ/Ω 13 kΩ + 3.9 mΩ/Ω 0.44 MΩ + 3.9 mΩ/Ω Fluke 5500A Resistance – Measure3, 7 Up to 10 Ω (10 to 100) Ω (100 to 1000) Ω (1 to 10) kΩ (10 to 100) kΩ (100 to 1000) kΩ (1 to 10) MΩ (10 to 100) MΩ 3 mΩ + 0.1 mΩ/Ω 5 mΩ + 0.1 mΩ/Ω 20 mΩ + 0.1 mΩ/Ω 0.2 Ω + 0.1 mΩ/Ω 2 Ω + 0.1 mΩ/Ω 20 Ω + 0.1 mΩ/Ω 0.5 kΩ + 0.41 mΩ/Ω 90 kΩ + 8 mΩ/Ω Tektronix 4050
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 4 of 11 Parameter/Range Frequency CMC2, 5 (±) Comments Capacitance – Generate3, 7 (0.33 to 0.4999) nF (0.5 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.99) nF (110 to 329.99) nF (0.33 to 1.0999) µF (1.1 to 3.2999) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.99) µF (110 to 329.99) µF (0.33 to 1.1) mF (50 to 1000) Hz (50 to 1000) Hz (50 to 1000) Hz (50 to 1000) Hz (50 to 1000) Hz (50 to 1000) Hz (50 to 1000) Hz (50 to 1000) Hz (50 to 1000) Hz (50 to 400) Hz (50 to 400) Hz (50 to 200) Hz (50 to 100) Hz (50 to 100) Hz 8.5 pF + 3.9 pF/nF 9.4 pF + 3.9 pF/nF 12 pF + 3.9 pF/nF 21 pF + 3.9 pF/nF 99 pF + 2 pF/nF 0.14 nF + 2 pF/nF 0.45 nF + 2 pF/nF 1.4 nF + 2 nF/µF 5.4 nF + 2.8 nF/µF 17 nF + 3 nF/µF 59 nF + 3.3 nF/µF 0.21 µF + 4 nF/µF 0.84 µF + 5.5 nF/µF 2.8 µF + 12 µF/mF Fluke 5500A AC Voltage – Generate3, 7 (1.0 to 32.999) mV (33 to 329.999) mV (0.33 to 3.299 99) V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 18 µV + 2.7 µV/mV 17 µV + 1.2 µV/mV 17 µV + 1.6 µV/mV 18 µV + 1.9 µV/mV 29 µV + 2.7 µV/mV 61 µV + 7.6 µV/mV 0.1 mV + 1.9 µV/mV 37 µV + 0.37 µV/mV 43 µV + 0.77 µV/mV 73 µV + 1.2 µV/mV 0.19 mV + 1.9 µV/mV 0.45 mV + 5.4 µV/mV 0.83 mV + 1.1 mV/V 0.14 mV + 0.23 mV/V 0.26 mV + 0.62 mV/V 0.6 mV + 1.1 mV/V 1.9 mV + 1.9 mV/V 4 mV + 3.8 mV/V 5.9 mV + 1.2 mV/V 1.8 mV + 0.3 mV/V 4.3 mV + 0.62 mV/V 8.8 mV + 1.5 mV/V 19 mV + 1.9 mV/V 22 mV + 0.38 mV/V 34 mV + 0.62 mV/V 50 mV + 0.7 mV/V 0.19 V + 0.39 mV/V 0.59 V + 1.6 mV/V 0.9 V + 1.6 mV/V Fluke 5500A
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 5 of 11 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure3, 7 Up to 100 mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (100 to 320) V (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 52 µV + 10 µV/mV 46 µV + 3.5 µV/mV 47 µV + 0.57 µV/mV 64 µV + 1.1 µV/mV 0.13 mV + 5.7 µV/mV 0.59 mV + 40 µV/mV 1.3 mV + 10 mV/V 0.66 mV + 3.5 mV/V 0.42 mV + 0.56 mV/V 0.69 mV + 1.2 mV/V 1.6 mV + 5.9 mV/V 9.4 mV + 40 mV/V 13 mV + 10 mV/V 6.6 mV + 3.5 mV/V 4.6 mV + 0.54 mV/V 7.2 mV + 1.1 mV/V 17 mV + 5.8 mV/V 90 mV + 40 mV/V 0.13 V + 10 mV/V 67 mV + 3.5 mV/V 46 mV + 0.54 mV/V 69 mV + 1.2 mV/V 0.16 V + 5.9 mV/V 1.2 V + 10 mV/V 0.59 V + 3.5 mV/V 0.31 V + 0.58 mV/V 0.25 V + 1.2 mV/V 0.8 V + 6 mV/V Tektronix 4050
to 1000 V
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 6 of 11 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate3, 7 (0.029 to 0.329 99) mA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 2.199 99) A (2.2 to 11) A Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 550) A (10 to 16.5) A (16.5 to 150) A (150 to 550) A Non-Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 550) A (10 to 16.5) A (16.5 to 150) A (150 to 550) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 400) Hz 500 Hz to 1 kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.17 µA + 1.9 µA/mA 0.15 µA + 0.97 µA/mA 0.22 µA + 0.97 µA/mA 0.21 µA + 3.1 µA/mA 0.4 µA + 9.7 µA/mA 0.75 µA + 1.6 µA/mA 0.49 µA + 0.78 µA/mA 0.49 µA + 0.78 µA/mA 0.75 µA + 1.6 µA/mA 1.8 µA + 4.7 µA/mA 7.5 µA + 1.6 µA/mA 4.9 µA + 0.78 µA/mA 4.6 µA + 0.7 µA/mA 7.5 µA + 1.6 µA/mA 18 µA + 4.7 µA/mA 76 µA + 1.6 µA/mA 50 µA + 0.77 µA/mA 48 µA + 0.7 µA/mA 76 µA + 1.6 µA/mA 0.18 mA + 4.7 µA/mA 0.75 mA + 1.6 mA/A 0.49 mA + 0.78 mA/A 2.2 mA + 5.8 mA/A 3 mA + 0.47 mA/A 3.9 mA + 0.78 mA/A 9.3 mA + 2.6 mA/A 25 mA + 1.9 mA/A 55 mA + 2.4 mA/A 0.36 A + 2 mA/A 56 mA + 5.3 mA/A 0.11 A + 5.7 mA/A 0.87 A + 5.4 mA/A 59 mA + 3.8 mA/A 0.23 A + 4 mA/A 1.2 A + 3.8 mA/A 88 mA + 6.7 mA/A 0.28 A + 7 mA/A 1.6 A + 6.8 mA/A Fluke 5500A Fluke 5500A, w/ coil
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 7 of 11 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Measure3, 7 Up to 100 µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 3) A (1 to 10) A (3 to 5) Hz (5 to 10) Hz 10 Hz to 5 kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 5 kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 5 kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 5 kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 5 kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 5 kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 5 kHz (5 to 10) kHz 63 nA + 11 nA/µA 63 nA + 3.5 nA/µA 62 nA + 1.5 nA/µA 0.7 µA + 3.5 nA/µA 1.4 µA + 10 µA/mA 0.71 µA + 3 µA/mA 0.52 µA + 1 µA/mA 2.7 µA + 2 µA/mA 18 µA + 11 µA/mA 11 µA + 3.4 µA/mA 8.9 µA + 1.4 µA/mA 74 µA + 3.5 µA/mA 0.15 mA + 9.9 µA/mA 83 µA + 2.9 µA/mA 76 µA + 0.84 µA/mA 0.28 mA + 1.9 µA/mA 1.6 mA + 9.8 mA/A 1 mA + 2.7 mA/A 0.5 mA + 1.4 mA/A 7.4 mA + 4.3 mA/A 13 mA + 11 mA/A 5.3 mA + 3.5 mA/A 3.3 mA + 1.5 mA/A 25 mA + 3.5 mA/A 39 mA + 11 mA/A 17 mA + 3.5 mA/A 11 mA + 1.5 mA/A 81 mA + 3.5 mA/A Tektronix 4050
to 10 A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 8 of 11 Parameter/Equipment Range CMC2 (±) Comments Thermocouple – Indicating Systems & Measure3 Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.12 °C 0.14 °C 0.18 °C 0.26 °C 0.15 °C 0.13 °C 0.21 °C 0.31 °C 0.49 °C 0.21 °C 0.15 °C 0.14 °C Fluke 5500A Electrical Calibration of RTDs – Generate3 Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.058 °C 0.069 °C 0.082 °C 0.089 °C 0.1 °C 0.18 °C 0.058 °C 0.069 °C 0.082 °C 0.089 °C 0.1 °C 0.2 °C 0.053 °C 0.058 °C 0.063 °C 0.07 °C 0.076 °C 0.082 °C 0.043 °C 0.18 °C Fluke 5500A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 9 of 11 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTDs – Generate3 (cont) Pt 385, 100 Ω Pt 385, 500 Ω Pt 385, 1000 Ω Ni 385, 120 Ω Cu 427, 10 Ω (-200 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 100) °C (100 to 260) °C (260 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 600) °C (600 to 630) °C (-80 to 100) °C (100 to 260) °C (-100 to 260) °C 0.053 °C 0.058 °C 0.1 °C 0.11 °C 0.13 °C 0.053 °C 0.058 °C 0.064 °C 0.076 °C 0.082 °C 0.096 °C 0.049 °C 0.053 °C 0.058 °C 0.063 °C 0.069 °C 0.18 °C 0.076 °C 0.12 °C 0.24 °C Fluke 5500A III. Mechanical Parameter/Equipment Range CMC2, 4, 6 (±) Comments Scales3, 7 Up to 1000 lb (1000 to 60 000) lb 0.82 x UUT Resolution 0.45 lbf + [0.0064 % x (f – 1000)] Class F weights Load cells f = force applied Force – Measuring Equipment, Tension & Compression 3 Up to 1000 lbf (1000 to 60 000) lbf 0.0023 % 0.45 lbf + [0.0064 % x (f – 1000)] Class F weights Load cells f = force applied
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 10 of 11 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Torque – Measuring Equipment, Tools3 (20 to 200) ozf·in (10 to 50) lbf·in (50 to 1000) lbf·in (83 to 600) lbf·ft 0.62 % 0.3 % 0.31 % 0.3 % CDI torque calibration system Pressure – Measuring Equipment3, 7 Differential (-13.5 to 30) psi (10 to 100) psi (50 to 500) psi (100 to 1000) psi (300 to 3000) psi (1000 to 10 000) psi (0 to 1) psid 0.027 psi 0.059 psi 0.29 psi 0.59 psi 2.8 psi 9.4 psi 0.0018 psi Fluke 754 w/ 700PD5 700P06 700P07 700P08 700P29 700P31 700P22 IV. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure3, 7 (-20 to 150) °C 0.49 °C Vaisala MI70, HMP77B Relative Humidity – Measure3, 7 (20 to 90) % RH (90 to 95) % RH 1.4 % RH 2.1 % RH Vaisala MI70, HMP77B V. Time & Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments Frequency – Measuring Equipment 1 µHz to 80 MHz 0.58 µHz + 2.3 µHz/Hz Agilent 33250A Frequency – Measure (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 300 kHz 300 kHz to 1 MHz 0.12 % 0.058 % 0.035 % 0.015 % 0.013 % Tektronix 4050 ___________________________________________
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2516.03) 2/4/2026 Page 11 of 11 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 Uncertainty components that can be reasonably attributed to the Unit Under Test have not been utilized in the calculation of the CMC value for this measurement parameter. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
12ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

320 Airbus Way, Mobile, AL, 36607, US

30.69135, -88.04375

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.