FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
United Kingdom

Cambridge Fire Research

Brewery Road, Pampisford, CB22 3HG, Cambridge, United Kingdom

UKAS|4319ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
6
Standards
15
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Cambridge Fire Research?

Claim this profile to keep it accurate.

Register record

UKASRefreshed
4319Active

Accredited standards

15

Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN

EN 438-7Name not checked yet
As written on the certificate · Line 3 (UKAS 4319)

EN 438-7:2005; EN14351-1:2006+A1:2010+A2:2016; EAD 210005-00-0505

As written on the certificate · Line 5 (UKAS 4319)

EN 438-7:2005; EN14351-1:2006+A1:2010+A2:2016

EN 520Name not checked yet
As written on the certificate · Line 2 (UKAS 4319)

EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2016; EAD 210005-00-0505

As written on the certificate · Line 4 (UKAS 4319)

ISO/IEC 17025:2017; EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2006; EAD 210005-00-0505

EN 845-2Name not checked yet
As written on the certificate · Line 2 (UKAS 4319)

EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2016; EAD 210005-00-0505

As written on the certificate · Line 4 (UKAS 4319)

ISO/IEC 17025:2017; EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2006; EAD 210005-00-0505

EN 1363-1Name not checked yet
As written on the certificate · Line 1 (UKAS 4319)

BS EN 13501-2:2023; BS EN 1363-1:2020 BS EN 1363-2:1999; BS EN 1364-1:2015 Door and shutter assemblies Fire resistance BS 476 Part 22:1987; BS EN 1634-1:2014; BS EN 1364-1:2015 Penetration seals Fire resistance BS EN 1366-3:2021

EN 1363-2Name not checked yet
As written on the certificate · Line 1 (UKAS 4319)

BS EN 13501-2:2023; BS EN 1363-1:2020 BS EN 1363-2:1999; BS EN 1364-1:2015 Door and shutter assemblies Fire resistance BS 476 Part 22:1987; BS EN 1634-1:2014; BS EN 1364-1:2015 Penetration seals Fire resistance BS EN 1366-3:2021

EN 1364-1Name not checked yet
As written on the certificate · Line 1 (UKAS 4319)

BS EN 13501-2:2023; BS EN 1363-1:2020 BS EN 1363-2:1999; BS EN 1364-1:2015 Door and shutter assemblies Fire resistance BS 476 Part 22:1987; BS EN 1634-1:2014; BS EN 1364-1:2015 Penetration seals Fire resistance BS EN 1366-3:2021

As written on the certificate · Line 6 (UKAS 4319)

EN 1364-1:2015; EN 1366-3:2021+A1:2024; EN 1366-4:2021; EN 1634-1:2014

EN 1366-3Name not checked yet
As written on the certificate · Line 1 (UKAS 4319)

BS EN 13501-2:2023; BS EN 1363-1:2020 BS EN 1363-2:1999; BS EN 1364-1:2015 Door and shutter assemblies Fire resistance BS 476 Part 22:1987; BS EN 1634-1:2014; BS EN 1364-1:2015 Penetration seals Fire resistance BS EN 1366-3:2021

As written on the certificate · Line 6 (UKAS 4319)

EN 1364-1:2015; EN 1366-3:2021+A1:2024; EN 1366-4:2021; EN 1634-1:2014

EN 1366-4Name not checked yet
As written on the certificate · Line 6 (UKAS 4319)

EN 1364-1:2015; EN 1366-3:2021+A1:2024; EN 1366-4:2021; EN 1634-1:2014

EN 1634-1Name not checked yet
As written on the certificate · Line 1 (UKAS 4319)

BS EN 13501-2:2023; BS EN 1363-1:2020 BS EN 1363-2:1999; BS EN 1364-1:2015 Door and shutter assemblies Fire resistance BS 476 Part 22:1987; BS EN 1634-1:2014; BS EN 1364-1:2015 Penetration seals Fire resistance BS EN 1366-3:2021

As written on the certificate · Line 6 (UKAS 4319)

EN 1364-1:2015; EN 1366-3:2021+A1:2024; EN 1366-4:2021; EN 1634-1:2014

EN 12859Name not checked yet
As written on the certificate · Line 2 (UKAS 4319)

EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2016; EAD 210005-00-0505

As written on the certificate · Line 4 (UKAS 4319)

ISO/IEC 17025:2017; EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2006; EAD 210005-00-0505

EN 13279-1Name not checked yet
As written on the certificate · Line 2 (UKAS 4319)

EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2016; EAD 210005-00-0505

As written on the certificate · Line 4 (UKAS 4319)

ISO/IEC 17025:2017; EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2006; EAD 210005-00-0505

EN 13501-2Name not checked yet
As written on the certificate · Line 1 (UKAS 4319)

BS EN 13501-2:2023; BS EN 1363-1:2020 BS EN 1363-2:1999; BS EN 1364-1:2015 Door and shutter assemblies Fire resistance BS 476 Part 22:1987; BS EN 1634-1:2014; BS EN 1364-1:2015 Penetration seals Fire resistance BS EN 1366-3:2021

EN 13950Name not checked yet
As written on the certificate · Line 2 (UKAS 4319)

EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2016; EAD 210005-00-0505

As written on the certificate · Line 4 (UKAS 4319)

ISO/IEC 17025:2017; EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2006; EAD 210005-00-0505

EN 14190Name not checked yet
As written on the certificate · Line 2 (UKAS 4319)

EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2016; EAD 210005-00-0505

As written on the certificate · Line 4 (UKAS 4319)

ISO/IEC 17025:2017; EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2006; EAD 210005-00-0505

EN 14496Name not checked yet
As written on the certificate · Line 2 (UKAS 4319)

EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2016; EAD 210005-00-0505

As written on the certificate · Line 4 (UKAS 4319)

ISO/IEC 17025:2017; EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2006; EAD 210005-00-0505

Scope as published by UKAS

6 lines
UKAS

ISO/IEC 17025

Active

4319

View scope

Accredited scope, certificate 4319

LineDisciplineMethodMatrixRange
1Electrical TestingBS EN 13501-2:2023; BS EN 1363-1:2020 BS EN 1363-2:1999; BS EN 1364-1:2015 Door and shutter assemblies Fire resistance BS 476 Part 22:1987; BS EN 1634-1:2014; BS EN 1364-1:2015 Penetration seals Fire resistance BS EN 1366-3:2021Building products; Elements of building construction; Walls and partitions; Door and shutter assemblies; Glazing; Penetration seals; Linear joint seals-
2Materials TestingEN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2016; EAD 210005-00-0505--
3materialsEN 438-7:2005; EN14351-1:2006+A1:2010+A2:2016; EAD 210005-00-0505Internal partition kits (for fire compartmentation); Panels (as internal or external finishes, as complete elements, used for fire protection of walls or ceilings); Doors and gates (with or without related hardware)-
4Materials TestingISO/IEC 17025:2017; EN 13950:2014; EN 14190:2014; EN 14496:2005; EN 520:2004+A1:2009; EN 12859:2011; EN 13279-1:2008; EN 845-2:2003+A1:2006; EAD 210005-00-0505Gypsum products; Masonry and related products; Internal partition kits-
5materialsEN 438-7:2005; EN14351-1:2006+A1:2010+A2:2016Construction products and materials-
6Electrical TestingEN 1364-1:2015; EN 1366-3:2021+A1:2024; EN 1366-4:2021; EN 1634-1:2014--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Brewery Road, Pampisford, Cambridge, CB22 3HG, GB

52.20553, 0.11866

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.