GEDISA CONSULTORES
Polígono Industrial La Cerrajera, Calle Panaderos, parcela 66, 16003, Cuenca, Spain
- Accredited standards
- 4
- ENAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ENAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 4 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 27888Water quality - Determination of electrical conductivity
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7393-2Water quality - Determination of free chlorine and total chlorine - Part 2: Colorimetric method using N,N-dialkyl-1,4-phenylenediamine, for routine control purposes
ISO 10523Water quality - Determination of pH
UNE-EN ISO/IEC 17025:2017; PNT02; PNT03; PNT05; UNE-EN ISO 10523; PNT06; UNE-EN 27888; PNT07; UNE-EN ISO 7393-2; PNT08; UNE-EN ISO 7027-1
Read from the scope as published by ENAC. Register refreshed 2026-10-10.
Scope as published by ENAC
1 line
ISO/IEC 17025
Active1559/LE2835
Accredited scope, certificate 1559/LE2835
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNE-EN ISO/IEC 17025:2017; PNT02; PNT03; PNT05; UNE-EN ISO 10523; PNT06; UNE-EN 27888; PNT07; UNE-EN ISO 7393-2; PNT08; UNE-EN ISO 7027-1 | Alimentos; Hisopos; Esponjas; Aguas de consumo; Auas envasadas; Aguas de piscinas; Aguas no tratadas | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Polígono Industrial La Cerrajera, Calle Panaderos, parcela 66, Cuenca, 16003, ES
40.06610, -2.13135
Open in MapsAccreditation data refreshed from the ENAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.