Gdańska Stocznia "Remontowa" im. J. Piłsudskiego
ul. Na Ostrowiu 1, 80-958, Gdańsk, Poland
- Accredited standards
- 16
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 16 standard numbers and the 11 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO7
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 8288Water quality - Determination of cobalt, nickel, copper, zinc, cadmium and lead - Flame atomic absorption spectrometric methods
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 10523Water quality - Determination of pH
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
Other standards9
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidance
PN-83/E-04040.03
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-04008-7:2002+Az1:2004
PN-Z-04469
PN-Z-04472
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04508:2022-05
PN-N-01307:19 94; PN-EN ISO 9612:2011; PN-EN-ISO 5349-1:2004; PN-EN-ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015 -11; PN-EN 14253+A1:2011
PN-ISO 5667-10:2021 -11; PN-EN ISO 10523:2012; PN-EN 872:2007 + Ap1:2007; PN-ISO 15705:2005; PB-06 ed. 2 z dn. 01.08.2024 r.; PB-04 ed. 3 z dn. 01.08.2024 r.; PN-ISO 8288:2002
PN-Z-04508:2022 -05; PN-Z-04508:2022 -05/Ap1:2022 -08; PB-8 ed. 2 z dn. 18.08.2025 r.; PN-Z-04472:2015 -10+Ap1:2015 -12; PN-Z-04469:2025 -02; PN-83/E-04040.03; PB-3 ed. 5 z dn. 21.05.2021r.
PN-Z-04008 -7:2002; PN-Z-04008 -7:2002/Az1:2004; PN-Z-04507:2022 -05; PN-Z-04507:2022 -05/Ap1:2022-08
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
5 lines
ISO/IEC 17025
ActiveAB 1285
The scope document we hold says it is valid until 2027-10-12.
Accredited scope, certificate AB 1285
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Waste waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 1285
Scope of accreditation No. AB 1285
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 1285
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 22 z/of 29.10.2025
KIEROWNIK DZIAŁU AKREDYTACJI
BADAŃ EMISJI W ŚRODOWISKU
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1285 z dnia 06.09.2019 r.
Cykl akredytacji od 22.09.2023 r. do 12.10.2027 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No . AB 1285 of 06.09.2019
Accreditation cycle from 22.09.2023 to 12.10.2027
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 22, 29.10.2025 1/6
Nazwa i adres / Name and address
GDAŃSKA STOCZNIA „REMONTOWA”
im. J. Piłsudskiego S.A.
Zespół ds. Ochrony Środowiska
ul. Na Ostrowiu 1
80-958 Gdańsk
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
− C/33/P, C/30/P
− C/28
− Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze) ,
ścieki / Chemical tests and sampling – working environment (harmful factors – air), sewage
− Badania chemiczne wody / Chemical tests of wa ter
− G/33
− Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy
(czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania) / Tests concerning environmental
engineering (environmental and climatic) - working environment (harmful and no isance factors
noise, lighting , vibration )
− N/33/P, N/30/P
− Badania właściwości fizycznych i pobieranie próbek - środowisko pracy (czynniki szkodliwe –
powietrze), ścieki / Tests of physical properties and sampling – working environment (harmful
factors – air), sewage
− P/33 − Pobieranie próbek powietrza / Sampling of air
Wersja strony/Page version : A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 1285 | - |
| 2 | PN-Z-04008 -7:2002; PN-Z-04008 -7:2002/Az1:2004; PN-Z-04507:2022 -05; PN-Z-04507:2022 -05/Ap1:2022-08 | Workplace air | 0.19 to 34.72 mg/m 3 |
| 3 | PN-Z-04508:2022 -05; PN-Z-04508:2022 -05/Ap1:2022 -08; PB-8 ed. 2 z dn. 18.08.2025 r.; PN-Z-04472:2015 -10+Ap1:2015 -12; PN-Z-04469:2025 -02; PN-83/E-04040.03; PB-3 ed. 5 z dn. 21.05.2021r. | Air | See scope document |
| 4 | PN-N-01307:19 94; PN-EN ISO 9612:2011; PN-EN-ISO 5349-1:2004; PN-EN-ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015 -11; PN-EN 14253+A1:2011 | Workplace environment | See scope document |
| 5 | PN-ISO 5667-10:2021 -11; PN-EN ISO 10523:2012; PN-EN 872:2007 + Ap1:2007; PN-ISO 15705:2005; PB-06 ed. 2 z dn. 01.08.2024 r.; PB-04 ed. 3 z dn. 01.08.2024 r.; PN-ISO 8288:2002 | Waste water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Laboratorium Badawcze EHS-LABKraków · ~492 kmPCAShares 6 accredited methods and materialsEN ISO 9612:2011PN-83/E-04040.03Air
- Centralne Laboratorium Pomiarowo-BadawczeJastrzębie Zdrój · ~498 kmPCAShares 6 accredited methods and materialsEN ISO 10523:2012EN ISO 9612:2011PN-83/E-04040.03
- Laboratorium Usługowo-Badawcze "Biochemik"Piła · ~197 kmPCAShares 5 accredited methods and materialsEN ISO 10523:2012AirWaste water
- AQUANET Laboratorium Spółka z o.o.Poznań · ~258 kmPCAShares 5 accredited methods and materialsEN ISO 10523:2012PN-83/E-04040.03Waste water
- TES LABORATORIUM Spółka z ograniczoną odpowiedzialnościąWarszawa · ~288 kmPCAShares 5 accredited methods and materialsPN-83/E-04040.03AirWaste water
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.