A2LA 4674.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
55
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 55 standard numbers and the 19 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI23
ETSI EN 300 113
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330-1
ETSI EN 300 330-2
ETSI EN 300 422-1
ETSI EN 300 440
ETSI EN 301 357
Show all 23
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
ETSI EN 302 208-1
ETSI EN 302 208-2
ETSI EN 303 345-1
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI TS 103 701
IEC12
IEC 60086-4
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61951-1
IEC 61951-2
IEC 61960-3
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62133-1
IEC 62133-2Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
IEC 62281
IEC 62619Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
IEC 62680-1-2
IEC 62680-1-3Exclusion

Limits written next to it

BS EN IEC 62680-1-3 (excluding 3, 6)

Exclusion. Written next to it on line 4 of A2LA certificate 4674.01.

IEC 61000 series6
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national

National versions in the same scope

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national

National versions in the same scope

AS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

EN4
EN 50332-1
EN 50332-2
EN 50563
EN 50564
EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
RSS-GEN

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

4674.01

The scope document we hold says it is valid until 2027-12-31.

View scope

Accredited scope, certificate 4674.01

LineMethodMatrixRange
147 CFR, FCC Part 15B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); 47 CFR, FCC Part 15C (using ANSI C63.10:2013); ANSI C63.4:2014; ANSI C63.10:2013; MP-5:1986; ANSI C63.4; ANSI C63.10; ICES-001; ICES-003; ICES-005; ICES-006; CISPR 11; AS CISPR 11; J55011; EN 55011; BS EN 55011; HKTA 1007; CISPR 14-1; AS/NZS CISPR 14.1; J55014-1; EN IEC 55014-1; BS EN IEC 55014-1; CISPR 15; AS CISPR 15; J55015; EN IEC 55015; BS EN IEC 55015; CISPR 32; AS/NZS CISPR 32; J55032; EN 55032; BS EN 55032; IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2; IEC 62040-2; EN IEC 62040-2; BS IEC 62040-2; VCCI V-3 (up to 6 GHz); EN IEC 61000-3-2; IEC 61000-3-2; BS EN IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; BS EN 61000-3-2; EN 61000-4-2; IEC 61000-4-2; BS EN 61000-4-2; EN IEC 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-3; EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5-to 6 GHz
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4674.01) 10/09/2025 Page 2 of 6 Test Technology: Test Method(s) 1: Conducted Immunity EN 61000-4-6; IEC 61000-4-6; BS EN 61000-4-6 VDI EN 61000-4-11; IEC 61000-4-11; BS EN IEC 61000-4-11 Magnetic Field EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-8 Generic and Product Family Standards IEC 61000-6-1; BS EN IEC 61000-6-1; EN IEC 61000-6-1; IEC 61000-6-2; BS EN IEC 61000-6-2; EN IEC 61000-6-2; IEC 61000-6-3; BS EN 61000-6-3; EN IEC 61000-6-3; AS/NSZ 61000.6.3; IEC 61000-6-4; BS EN IEC 61000-6-4; EN IEC 61000-6-4; AS/NSZ 61000.6.4; IEC 61547; EN 61547; BS EN 61547; IEC 61326-1; EN IEC 61326-1; BS EN IEC 61326-1; CISPR 35; EN 55035; BS EN 55035; CISPR 14-2; EN IEC 55014-2; BS EN IEC 55014-2; EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-9; EN 301 489-17; EN 301 489-19; EN 301 489-33; EN 301 489-34; EN 301 489-50; EN 301 489-52 Product Safety UL 62368-1; IEC 62368-1; EN 62368-1; EN IEC 62368-1; BS EN IEC 62368-1; AS/NZS 62368.1; J62368-1; JIS C 62368-1; CSA C22.2 No. 62368-1 (excluding three-phase equipment, 5.4.2.3.2, 5.4.1.10.2, 5.4.4.6.5, 5.4.8 (over 85cmX80cmX60cm), 5.4.4.9 (frequencies higher than 30 kHz), 5.4.10, 5.4.11, 5.4.12, 5.5, 8.5.5, 8.10, 8.11, 10.3, 10.4, 10.5, Annex C, Annex G, S.3, S.5, Annex U, & Annex Y); UL 2738; UL 1310; UL 2089; IEC 61558-1; EN IEC 61558-1; BS EN IEC 61558-1; AS/NZS 61558.1; IEC 61558-2-16; EN IEC 61558-2-16; BS EN IEC 61558-2-16; AS/NZS 61558.2.16; IEC 60335-1:2020; EN IEC 60335-1; BS EN IEC 60335-1; UL 60335-1; AS/NZS 60335.1; CAN/CSA-C22.2 No. 60335-1; J60335-1; IEC 60335-2-2:2019; EN IEC 60335-2-2; BS EN IEC 60335-2-2; UL 60335-2-2; AS/NZS 60335.2.2; CAN/CSA-C22.2 No. 60335-2-2; J60335-2-2; JIS C 9335-1; JIS C 9335-2-2; IEC 60335-2-52; EN 60335-2-52; BS EN 60335-2-52; AS/NZS 60335.2.52; UL 1431; CAN/CSA-C22.2 No 60335-2-52; J60335-2-52; JIS C 9335-2-52 Radio Communications Intentional and Unintentional Radiators 47 CFR, FCC Parts 15C, E, and F (using ANSI C63.4:2014, ANSI C63.10:2013, and FCC KDB 905462); 47 CFR, FCC Parts 22, 24, 25, 27, 90, and 96 (using ANSI/TIA-603-E, TIA 102.CAAA-E, and ANSI C63.26:2015); ANSI C63.10; ANSI C63.10-2020; ANSI C63.10-2020+Cor.1-2023; ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024; ANSI C63.26;
3RSS-GEN; RSS-102; RSS-102.NS.MEAS; RSS-102.NS.SIM; RSS-112; RSS-130; RSS-131; RSS-132; RSS-133; RSS-134; RSS-139; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199; RSS-210 (≤ 40 GHz); RSS-213; RSS-216 (≤ 40 GHz); RSS-220 (≤ 40 GHz); RSS-247; RSS-310; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 330; ETSI EN 300 330-1; ETSI EN 300 330-2; ETSI EN 300 440; ETSI EN 300 113; ETSI EN 302 208-1; ETSI EN 302 208-2; ETSI EN 302 208; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 301 357; EN 300 422-1; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 303 345-1; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-13; HKCA 1020; HKCA 1039; HKCA 1042; HKCA 1048; HKCA 1046; HKCA 1034; HKCA 1043; AS/ACIF S042.3; AS/CA S042.4; ARIB T-33; ARIB T-66; ARIB T-71; Article 2, Paragraph 1 of the Ordinance: Item 19; Item 19-2; Item 19-2-2; Item 19-2-3; Item 19-3; Item 11-3; Item 11-7; Item 11-19; Item 47; Item 78; MIC Notice No. 88, Appendix No. 43; MIC Notice No. 88, Appendix No. 44; AS/NZS 4268; EN 50332-1; BS EN 50332-1; EN 50332-2; BS EN 50332-2; Qi Specification Qi SpecificationPower Transmitter Compliance Tests V1.3.3; Qi Specification Power Transmitter Compliance Tests Version 2.1; Qi Specification MPP Power Transmitter Compliance Tests Version 2.1; Qi Specification Power Receiver Compliance Tests Version 2.1; Qi Specification MPP Power Receiver Compliance Tests Version 2.1; Qi Specification MC-PRx Compliance Tests Version 2.1; Qi Specification Power Transmitter Compliance Tests Version 2.2; Qi Specification MPP Power Transmitter Compliance Tests Version 2.2; Qi Specification Power Receiver Compliance Tests Version 2.2; Qi Specification MPP Power Receiver Compliance Tests Version 2.2; Qi Specification MC-PRx Compliance Tests Version 2.2-to 40 GHz
4IEC 62133-1; EN 62133-1; BS EN 62133-1; JIS C 62133-1; IEC 62133-2; EN 62133-2; BS EN 62133-2; J62133-2; JIS C 62133-2; UL 62133-2; UL 1642; UL 2056; UL 2054; UL 2743; UL 4200A; ANSI/UL 2743; ANSI/CAN/UL 2743; IEC 61951-1; EN 61951-1; BS EN 61951-1; IEC 61951-2; EN 61951-2; BS EN 61951-2; IEC 61960-3; EN 61960-3; BS EN 61960-3; JIS C 8712; IEC 62281; EN IEC 62281; BS EN IEC 62281; IEC 60086-4; EN IEC 60086-4; BS EN IEC 60086-4; IEC 62619; EN IEC 62619; BS EN IEC 62619; UN/ST/SG/AC.10/1/Rev.21 Chapter 3.3 238; UN/ST/SG/AC.10/1/Rev.23 Chapter 3.3 238; UN/ST/SG/AC.10/1/Rev.22(V01.I); UN/ST/SG/AC.10/1/Rev.23(V01.II); ST/SG/AC.10/1/Rev.22(V01.II); ST/SG/AC.10/1/Rev.23(V01.II); ST/SG/AC.10/11/Rev.7/Amend.1 38.3; ST/SG/AC.10/11/Rev.8 38.3; IEC 62680-1-2; EN IEC 62680-1-2; BS EN IEC 62680-1-2; SASO-IEC-62680-1-2; IEC 62680-1-3; EN IEC 62680-1-3; BS EN IEC 62680-1-3; SASO-IEC-62680-1-3; 10 CFR Part 430.32 (w); Title 20. Division 2. Chapter 4. Article 4:1605.1 (u); Title 20. Division 2. Chapter 4. Article 4:1604 (u); 10 CFR Part 430.32(z); Title 20. Division 2. Chapter 4. Article 4:1605.1 (w); Title 20. Division 2. Chapter 4. Article 4:1604 (w); (EU) 2023/826; (EU) No 2019/1782; EN 50563; EN 50564--
5EN 18031-1; BS EN 18031-1; EN 18031-2; BS EN 18031-2; EN 18031-3; BS EN 18031-3; ETSI TS 103 701; Qi Specification Qi Specification Power Transmitter Compliance Tests V1.3.3; Qi Specification Power Transmitter Compliance Tests Version 2.1; Qi Specification MPP Power Transmitter Compliance Tests Version 2.1; Qi Specification Power Transmitter Compliance Tests Version 2.2; Qi Specification MPP Power Transmitter Compliance Tests Version 2.2--
6ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462; ANSI/TIA-603-E; TIA 102.CAAA-E; ANSI C63.26:2015-to 40000 MHz
7

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SHENZHEN MICROTEST CO., LTD. Shenzhen, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 9th day of October 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4674.01 Valid to December 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.