Omni-Tech Corporation
1460 Torrey Rd. Ste A, 48430-3323, Fenton, MI, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Omni-Tech Corporation?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 1791.01Active
Accredited standards
2Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ISO 10360-2Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 2: CMMs used for measuring linear dimensions
ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ISO 10360-2; ISO 10360-5; ANSI/ASME B89.4.1b-2001
ISO 10360-5Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 5: Coordinate measuring machines (CMMs) using single and multiple stylus contacting probing systems using discrete point and/or scanning measuring mode
ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ISO 10360-2; ISO 10360-5; ANSI/ASME B89.4.1b-2001
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active1791.01
The scope document we hold says it is valid until 2028-02-29.
Accredited scope, certificate 1791.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | dimensional | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ISO 10360-2; ISO 10360-5; ANSI/ASME B89.4.1b-2001 | - | 0.1 to 10 m |
| 2 | - | (A2LA Cert. No. 1791.01) 12/23/2025 Page 2 of 2
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured
in inches or meters.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | - | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Trescal, Inc. - DetroitHowell, MI · ~28 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- NOVASTAR SOLUTIONS.COM LLC DBA NOVASTAR METROLOGYLivonia, MI · ~56 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Equipment Services GroupFerndale, MI · ~60 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- InCal TechnologiesSaginaw, MI · ~72 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- TESTCAL PLUSRiverview, MI · ~82 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.