Omni-Tech Corporation
1460 Torrey Rd. Ste A, 48430-3323, Fenton, MI, United States
Visit website- Accredited standards
- 2
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 2 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 10360-2Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 2: CMMs used for measuring linear dimensions
ISO 10360-5Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 5: Coordinate measuring machines (CMMs) using single and multiple stylus contacting probing systems using discrete point and/or scanning measuring mode
ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ISO 10360-2; ISO 10360-5; ANSI/ASME B89.4.1b-2001
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active1791.01
The scope document we hold says it is valid until 2028-02-29.
Accredited scope, certificate 1791.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ISO 10360-2; ISO 10360-5; ANSI/ASME B89.4.1b-2001 | - | 0.1 to 10 m |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1791.01) 12/23/2025 Page 2 of 2
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured
in inches or meters.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Trescal, Inc. - DetroitHowell, MI · ~28 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- NOVASTAR SOLUTIONS.COM LLC DBA NOVASTAR METROLOGYLivonia, MI · ~56 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Equipment Services GroupFerndale, MI · ~60 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- InCal TechnologiesSaginaw, MI · ~72 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- TESTCAL PLUSRiverview, MI · ~82 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.