RIVACOLD
Via Mazzini, snc - Fraz. Montecchio, 61022, Vallefoglia, Italy
Visit website- Accredited standards
- 18
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 18 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.
EN6
EN 328
EN 13215
EN 13771-1
EN 13771-2
EN 16825
EN 16902
ISO4
ISO 3744Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane
ISO 22041Refrigerated storage cabinets and counters for professional use - Performance and energy consumption
ISO 22043Ice-cream freezers - Classification, requirements and test conditions
ISO 22044Commercial beverage coolers - Classification, requirements and test conditions
EN 14511 series3
EN 14511-2
EN 14511-3
EN 14511-4
IEC 62552 series3
IEC 62552-1
IEC 62552-2
IEC 62552-3
Other standards2
IEC 60704-1
IEC 60704-2-14
UNI CEI EN ISO/IEC 17025:2018; EN ISO 22044:2022; ISO 22044:2021; UNI EN ISO 22044:2022; EN 16902:2016; EN 328:2014; EN ISO 3744:2010; ISO 3744:2010; ISO 3744:2025; UNI EN ISO 3744:2010
EN 16825:2016/A1:2019 + Reg UE 1095/2015 05/05/2015 GU UE L177 08/07/2015 + REG UE 1094/2015 05/05/2015 GU UE L177 08/07/2015; UNI EN 16825:2019 + Reg UE 1095/2015 05/05/2015 GU UE L177 08/07/2015 + REG UE 1094/2015 05/05/2015 GU UE L177 08/07/2015; EN ISO 22041:2019/A1:2019 + REG UE 1095/2015 05/05/2015 GU UE L177 08/07/2015 + REG UE 1094/2015 05/05/2015 GU UE L177 08/07/2015, UNI EN ISO 22041:2020 + REG UE 1095/2015 05/05/2015 GU UE L177 08/07/2015 + REG UE 1094/2015 05/05/2015 GU UE L177 08/07/2015; EN ISO 22043:2020; ISO 22043:2020; UNI EN ISO 22043:2021; EN 13771-2:2017 + EN 13215:2016/A1:2020 + Reg UE 1095/2015 05/05/2015 GU UE L177 08/07/2015; EN 13771-1:2016; EN 14511-2:2022 + EN 14511-4:2022 + EN 14511-3:2022; UNI EN 14511-2:2022 + UNI EN 14511-4:2022 + UNI EN 14511-3:2022
CEI EN 62552-3:2021/A11:2024; EN 62552-3:2020; EN 62552-3:2020/A11:2024; IEC 62552-3:2015/AMD1:2020; CEI EN 62552-2:2021/A11:2024; EN 62552-2:2020; EN 62552-2:2020/A11:2024; IEC 62552-2:2015/A1:2020; CEI EN 62552-1:2021/A11:2024; EN 62552-1:2020; EN 62552-1:2020/A11:2024; IEC 62552-1:2015/A1:2020; CEI EN 60704-2-14:2013/A11:2016/A1:2019 + CEI EN 60704-1:2011/A11:2014 + UNI EN ISO 3744:2010; CEI EN 60704-2-14:2013/A11:2016/A1:2019/A2:2024 + CEI EN IEC 60704-1:2022 + UNI EN ISO 3744:2010; EN 60704-2-14:2013/A11:2015/A1:2019 + EN IEC 60704-1:2021 + EN ISO 3744:2010; EN 60704-2-14:2013/A11:2015/A1:2019/A2:2024 + EN IEC 60704-1:2021 + EN ISO 3744:2010; IEC 60704-2-14:2013/AMD1:2019 + IEC 60704-1:2021 + ISO 3744:2010; IEC 60704-2-14:2013/AMD1:2019/AMD2:2024 + IEC 60704-1:2021 + ISO 3744:2010
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
3 lines
ISO/IEC 17025
Active01454
Accredited scope, certificate 01454
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | EN 16825:2016/A1:2019 + Reg UE 1095/2015 05/05/2015 GU UE L177 08/07/2015 + REG UE 1094/2015 05/05/2015 GU UE L177 08/07/2015; UNI EN 16825:2019 + Reg UE 1095/2015 05/05/2015 GU UE L177 08/07/2015 + REG UE 1094/2015 05/05/2015 GU UE L177 08/07/2015; EN ISO 22041:2019/A1:2019 + REG UE 1095/2015 05/05/2015 GU UE L177 08/07/2015 + REG UE 1094/2015 05/05/2015 GU UE L177 08/07/2015, UNI EN ISO 22041:2020 + REG UE 1095/2015 05/05/2015 GU UE L177 08/07/2015 + REG UE 1094/2015 05/05/2015 GU UE L177 08/07/2015; EN ISO 22043:2020; ISO 22043:2020; UNI EN ISO 22043:2021; EN 13771-2:2017 + EN 13215:2016/A1:2020 + Reg UE 1095/2015 05/05/2015 GU UE L177 08/07/2015; EN 13771-1:2016; EN 14511-2:2022 + EN 14511-4:2022 + EN 14511-3:2022; UNI EN 14511-2:2022 + UNI EN 14511-4:2022 + UNI EN 14511-3:2022 | Armadi e tavoli refrigerati per uso professionale/Refrigerated storage cabinets and counters for professional use; Banchi surgelati per gelato preconfezionato/Ice-cream freezers; Compressori e unità di condensazione per la refrigerazione/Compressors and condensing units for refrigeration; Condizionatori d'aria/Air conditioners, Deumidificatori/Dehumidifiers, Pompe di calore con compressore elettrico per il riscaldamento e il raffrescamento degli ambienti/Heat pumps with electrically driven compressors for space heating and cooling, Pompe di calore per il riscaldamento e il raffreddamento degli ambienti/Heat pumps for space heating and cooling, Refrigeratori di liquido/Liquid chilling packages, Refrigeratori di processo/Process chillers; Condizionatori d'aria/Air conditioners, Pompe di calore con compressore elettrico per il riscaldamento e il raffrescamento degli ambienti/Heat pumps with electrically driven compressors for space heating and cooling, Refrigeratori di liquido/Liquid chilling packages, Refrigeratori di processo/Process chillers | 0.01 to 8 kW |
| 2 | CEI EN 62552-3:2021/A11:2024; EN 62552-3:2020; EN 62552-3:2020/A11:2024; IEC 62552-3:2015/AMD1:2020; CEI EN 62552-2:2021/A11:2024; EN 62552-2:2020; EN 62552-2:2020/A11:2024; IEC 62552-2:2015/A1:2020; CEI EN 62552-1:2021/A11:2024; EN 62552-1:2020; EN 62552-1:2020/A11:2024; IEC 62552-1:2015/A1:2020; CEI EN 60704-2-14:2013/A11:2016/A1:2019 + CEI EN 60704-1:2011/A11:2014 + UNI EN ISO 3744:2010; CEI EN 60704-2-14:2013/A11:2016/A1:2019/A2:2024 + CEI EN IEC 60704-1:2022 + UNI EN ISO 3744:2010; EN 60704-2-14:2013/A11:2015/A1:2019 + EN IEC 60704-1:2021 + EN ISO 3744:2010; EN 60704-2-14:2013/A11:2015/A1:2019/A2:2024 + EN IEC 60704-1:2021 + EN ISO 3744:2010; IEC 60704-2-14:2013/AMD1:2019 + IEC 60704-1:2021 + ISO 3744:2010; IEC 60704-2-14:2013/AMD1:2019/AMD2:2024 + IEC 60704-1:2021 + ISO 3744:2010 | - | - |
| 3 | UNI CEI EN ISO/IEC 17025:2018; EN ISO 22044:2022; ISO 22044:2021; UNI EN ISO 22044:2022; EN 16902:2016; EN 328:2014; EN ISO 3744:2010; ISO 3744:2010; ISO 3744:2025; UNI EN ISO 3744:2010 | Heat exchangers - Forced convection unit air coolers for refrigeration; Noise sources (machinery and other equipment) | 0.2 to 30 kW |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.