Recal Calibration Services
1003 Cresthaven Drive, 76040, Euless, TX, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 1426.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1426.01) Revised 7/15/2026 Page 2 of 3
III. Mechanical
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Force3, Compression –
Measure
Up to 600 000 lbf
0.08 % Full Scale
ASTM E4 and standard
load cells
Scales & Balances3 –
Analytical Balances
Top Loader Balances
Industrial Scales
Up to 200 g
Up to 20 g
(20 to 200) g
200 g to 1 kg
(1 to 5) kg
(5 to 10) kg
(10 to 20) kg
Up to 300 lb
0.0004 % Full Scale
0.0002 % Full Scale
0.0002 % Full Scale
0.0003 % Full Scale
0.0004 % Full Scale
0.0014 % Full Scale
0.0059 % Full Scale
0.01 % Full Scale
Class 1 weights
Class 4 weights
Class F weights
Pressure Gages &
Transducers3
Up to 300 psi
0.12 % psi
Standard pressure
indicator
Vacuum – Measure3
Up to 29.5 in Hg
0.06 in Hg
Standard
pressure/vacuum
indicator
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Thermometers3
(0 to 350) ℃
0.19 ℃
PRT/indicator in dry
block
Temperature – Measure3
(0 to 660) ℃
(0 to 1220) ℉
0.59 ℃
1.4 ℉
Fluke 52 with
thermocouple
______________________________________________
1 This laboratory offers commercial calibration service and field calibration service. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1426.01) Revised 7/15/2026 Page 3 of 3
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards of nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be
considered and this, on its own, could result in the actual measurement uncertainty achievable on a
customer’s site being larger than the CMC.
4 In the statement of CMC, L is length measured in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Kimball ElectronicArlington, TX · ~12 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Tektronix, Inc - IrvingIrving, TX · ~13 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Dallas, TXIrving, TX · ~13 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - DallasDallas, TX · ~27 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Tektronix Inc. - DallasDallas, TX · ~27 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.