Recal Calibration Services

1003 Cresthaven Drive, 76040, Euless, TX, United States

Visit website
A2LA 1426.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 1426.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1426.01) Revised 7/15/2026 Page 2 of 3 III. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments Force3, Compression – Measure Up to 600 000 lbf 0.08 % Full Scale ASTM E4 and standard load cells Scales & Balances3 – Analytical Balances Top Loader Balances Industrial Scales Up to 200 g Up to 20 g (20 to 200) g 200 g to 1 kg (1 to 5) kg (5 to 10) kg (10 to 20) kg Up to 300 lb 0.0004 % Full Scale 0.0002 % Full Scale 0.0002 % Full Scale 0.0003 % Full Scale 0.0004 % Full Scale 0.0014 % Full Scale 0.0059 % Full Scale 0.01 % Full Scale Class 1 weights Class 4 weights Class F weights Pressure Gages & Transducers3 Up to 300 psi 0.12 % psi Standard pressure indicator Vacuum – Measure3 Up to 29.5 in Hg 0.06 in Hg Standard pressure/vacuum indicator IV. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Thermometers3 (0 to 350) ℃ 0.19 ℃ PRT/indicator in dry block Temperature – Measure3 (0 to 660) ℃ (0 to 1220) ℉ 0.59 ℃ 1.4 ℉ Fluke 52 with thermocouple ______________________________________________ 1 This laboratory offers commercial calibration service and field calibration service.
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1426.01) Revised 7/15/2026 Page 3 of 3 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards of nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is length measured in inches. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1003 Cresthaven Drive, Euless, TX, 76040, US

32.83707, -97.08195

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.