Pacific BioLabs
551 Linus Pauling Dr., 94547, Hercules, CA, United States
Visit website- Accredited standards
- 27
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 27 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.
USP14
USP 51
USP 61
USP 62
USP 71
USP 85
USP 87
USP 88
USP 121
USP 123
USP 151
USP 161
USP 643
USP 645
USP 1111
ISO 10993 series8
ISO 10993-1Biological evaluation of medical devices - Part 1: Requirements and general principles for the evaluation of biological safety within a risk management process
ISO 10993-5Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity
ISO 10993-6Biological evaluation of medical devices - Part 6: Tests for local effects after implantation
ISO 10993-10Biological evaluation of medical devices - Part 10: Tests for skin sensitization
ISO 10993-11Biological evaluation of medical devices - Part 11: Tests for systemic toxicity
ISO 10993-12Biological evaluation of medical devices - Part 12: Sample preparation and reference materials
ISO 10993-18Biological evaluation of medical devices - Part 18: Chemical characterization of medical device materials within a risk management process
ISO 10993-23Biological evaluation of medical devices - Part 23: Tests for irritation
ISO5
ISO 11137-2Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose
ISO 11737-1Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on products
ISO 11737-2Sterilization of health care products - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
ISO 14161Sterilization of health care products - Biological indicators - Guidance for the selection, use and interpretation of results
ISO 17665-1Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
USP <87>; USP <88>; ASNSI/AAMI/ISO 10993-5; ISO 10993-1; ANSI/AAMI/ISO 10993-12; USP <85>; USP <161>; ANSI/AAMI ST72:2011; EP 2.6.14; USP <51>; USP <71>; USP <61>; ANSI/AAMI/ISO 11737-1; AAMI TIR 33; ANSI/ AAMI/ISO 11137-2 Method 1; ANSI/AAMI/ISO 11137-2; AAMI/ISO TIR 15844; ANSI/AAMI/ISO 11737-2; USP<71>; USP <61>; USP <62>; USP <1111>; EP/BP; ISO 10993-11; USP<151>; 10993-11; 10993-5; USP<87>; 10993-12
ISO/IEC 17025:2017; ISO 10993-6; USP <88>; ISO 10993-11; USP <88>; ISO 10993-23; USP <88>; ISO 10993-11; <USP 151>; European Pharmacopoeia; USP <88>; ISO 10993-10; ISO 10993-10; ISO 10993-23; USP Monograph; EPA/OPPTS 870.1100; USP <123>; USP <121>; AAMI TIR12; ANSI/AAMI/ISO 17665-1; ANSI/AAMI/ISO 14161; USP <87>; ANSI/AAMI/ISO 10993-5; USP <87>; ANSI/ AAMI/ISO 10993-5; ANSI/AAMI/ISO 10993-12
USP <645>; USP <643>; ISO 10993-18
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active7312.01
The scope document we hold says it is valid until 2027-01-31.
Accredited scope, certificate 7312.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ISO 10993-6; USP <88>; ISO 10993-11; USP <88>; ISO 10993-23; USP <88>; ISO 10993-11; <USP 151>; European Pharmacopoeia; USP <88>; ISO 10993-10; ISO 10993-10; ISO 10993-23; USP Monograph; EPA/OPPTS 870.1100; USP <123>; USP <121>; AAMI TIR12; ANSI/AAMI/ISO 17665-1; ANSI/AAMI/ISO 14161; USP <87>; ANSI/AAMI/ISO 10993-5; USP <87>; ANSI/ AAMI/ISO 10993-5; ANSI/AAMI/ISO 10993-12 | Medical devices | - |
| 2 | USP <87>; USP <88>; ASNSI/AAMI/ISO 10993-5; ISO 10993-1; ANSI/AAMI/ISO 10993-12; USP <85>; USP <161>; ANSI/AAMI ST72:2011; EP 2.6.14; USP <51>; USP <71>; USP <61>; ANSI/AAMI/ISO 11737-1; AAMI TIR 33; ANSI/ AAMI/ISO 11137-2 Method 1; ANSI/AAMI/ISO 11137-2; AAMI/ISO TIR 15844; ANSI/AAMI/ISO 11737-2; USP<71>; USP <61>; USP <62>; USP <1111>; EP/BP; ISO 10993-11; USP<151>; 10993-11; 10993-5; USP<87>; 10993-12 | - | - |
| 3 | USP <645>; USP <643>; ISO 10993-18 | - | - |
| 4 | ISO/IEC 17025:2017; A2LA R256 - Specific Requirements - FDA ASCA Program | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Eurofins Infinity Laboratory GroupSan Jose, CA · ~83 kmA2LAShares 1 accredited materialMedical devices
- DDL, Inc. - DDL CAIrvine, CA · ~627 kmA2LAShares 1 accredited materialMedical devices
- Element Materials TechnologyMinnetonka, MN · ~2,506 kmA2LAShares 1 accredited materialMedical devices
- SterilucentMinneapolis, MN · ~2,522 kmA2LAShares 1 accredited materialMedical devices
- NORTH AMERICAN SCIENCE ASSOCIATES, LLC (NAMSA)St. Paul, MN · ~2,535 kmA2LAShares 1 accredited materialMedical devices
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.