What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 106 standard numbers and the 47 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60601 series26
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests+1 national
National versions in the same scope
KS C IEC 60601-1-2probably the same standard; matched by number only
IEC 60601-2-2
IEC 60601-2-5Some clauses
Limits written next to it
IEC 60601-2-5 (clause 201.17 only)
IEC 60601-2-5: Edition 3.0 2009-07 (clause 201.17 only) 12-205
IEC 60601-2-6Some clauses
Limits written next to it
IEC 60601-2-6 (clause 202 only)
IEC 60601-2-6 Edition 2.1 2016-04 (clause 202 only) 6-423
IEC 60601-2-10Some clauses
Limits written next to it
IEC 60601-2-10 (clause 202 only)
IEC 60601-2-10 Edition 2.1 2016-04 (clause 202 only) 17-16
IEC 60601-2-16Some clauses
Limits written next to it
IEC 60601-2-16 (clause 202 only)
IEC 60601-2-16 Edition 5.0 2018-4 (clause 202 only) 9-121
IEC 60601-2-18Some clauses
Limits written next to it
IEC 60601-2-18 (clause 202 only)
IEC 60601-2-18: Edition 3.0 2009-08 (clause 202 only) 9-114
IEC 60601-2-19Some clauses
Limits written next to it
IEC 60601-2-19 (clause 202 only)
IEC 60601-2-19 Edition 3.0 2020-09 (clause 202 only) 6-461
IEC 60601-2-20Some clauses
Limits written next to it
IEC 60601-2-20 (clause 202 only)
IEC 60601-2-20 Edition 3.0 2020-09 (clause 202 only) 6-462
IEC 60601-2-21Some clauses
Limits written next to it
IEC 60601-2-21 (clause 202 only)
IEC 60601-2-21 Edition 3.0 2020-09 (clause 202 only) 6-463
IEC 60601-2-23Some clauses
Limits written next to it
IEC 60601-2-23 (clause 202 only)
IEC 60601-2-23 Edition 3.0 2011-02 (clause 202 only) 1-87
IEC 60601-2-25Some clauses
Limits written next to it
IEC 60601-2-25 (clause 202 only)
IEC 60601-2-25 Edition 2.0 2011-10 (clause 202 only) 3-105
Show all 26
IEC 60601-2-27Some clauses
Limits written next to it
IEC 60601-2-27 (clause 202 only)
IEC 60601-2-27 Edition 3.0 2011-03 (clause 202 only) 3-126
IEC 60601-2-31Some clauses
Limits written next to it
IEC 60601-2-31 (clause 202 only)
IEC 60601-2-31 Edition 2.1 2011-09 (clause 202 only) 3-102
IEC 60601-2-33Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosisSome clauses
Limits written next to it
IEC 60601-2-33 (clause 202 only)
IEC 60601-2-34Some clauses
Limits written next to it
IEC 60601-2-34 (clause 202 only)
IEC 60601-2-34 Edition 3.0 2011-05 (clause 202 only) 3-115
IEC 60601-2-36Some clauses
Limits written next to it
IEC 60601-2-36 (clause 202 only)
IEC 60601-2-36 Edition 2.0 2014-04 (clause 202 only) 9-119
IEC 60601-2-37
IEC 60601-2-44Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomographySome clauses
Limits written next to it
IEC 60601-2-44 (clause 202 only)
IEC 60601-2-44 Edition 3.2: 2016 (clause 202 only) 12-302
IEC 60601-2-45Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devicesSome clauses
Limits written next to it
IEC 60601-2-45 (clause 202 only)
IEC 60601-2-45 Edition 3.1 2015 (clause 202 only) 12-294
IEC 60601-2-47Some clauses
Limits written next to it
IEC 60601-2-47 (clause 202 only)
IEC 60601-2-47 Edition 2.0 2012-02 (clause 202 only) 3-155
IEC 60601-2-50Some clauses
Limits written next to it
IEC 60601-2-50 (clause 202 only)
IEC 60601-2-50 Edition 3.0 2020-09 (clause 202 only) 6-450
IEC 60601-2-54Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopySome clauses
Limits written next to it
IEC 60601-2-54 (clause 202 only)
IEC 60601-2-62
IEC 60601-2-63Some clauses
Limits written next to it
IEC 60601-2-63 (clause 202 only)
IEC 60601-2-65Some clauses
Limits written next to it
IEC 60601-2-65 (clause 202 only)
ETSI24
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330-1
ETSI EN 300 330-2
ETSI EN 300 386-2
ETSI EN 300 440-1
ETSI EN 300 440-2
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-7
Show all 24
ETSI EN 301 489-17
ETSI EN 301 489-23
ETSI EN 301 489-24
ETSI EN 301 489-25
ETSI EN 301 489-26
ETSI EN 301 489-28
ETSI EN 301 489-29
ETSI EN 301 489-31
ETSI EN 301 489-33
ETSI EN 301 489-52
ETSI EN 302 208
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
IEC 61000 series20
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+2 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
KS C IEC 61000-3-2probably the same standard; matched by number only
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+2 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
KS C IEC 61000-3-3probably the same standard; matched by number only
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection+2 national
National versions in the same scope
AS/NZS 61000.3.11probably the same standard; matched by number only
KS C IEC 61000-3-11probably the same standard; matched by number only
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase+2 national
National versions in the same scope
AS/NZS 61000.3.12probably the same standard; matched by number only
KS C IEC 61000-3-12probably the same standard; matched by number only
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C IEC 61000-4-2probably the same standard; matched by number only
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
KS C IEC 61000-4-3probably the same standard; matched by number only
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
KS C IEC 61000-4-4probably the same standard; matched by number only
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national
National versions in the same scope
KS C IEC 61000-4-5probably the same standard; matched by number only
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national
National versions in the same scope
KS C IEC 61000-4-6probably the same standard; matched by number only
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national
National versions in the same scope
KS C IEC 61000-4-8probably the same standard; matched by number only
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test+1 national
National versions in the same scope
KS C IEC 61000-4-9probably the same standard; matched by number only
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national
National versions in the same scope
KS C IEC 61000-4-11probably the same standard; matched by number only
Show all 20
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test+1 national
National versions in the same scope
KS C IEC 61000-4-12probably the same standard; matched by number only
IEC 61000-4-34+1 national
National versions in the same scope
KS C IEC 61000-4-34probably the same standard; matched by number only
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test+1 national
National versions in the same scope
KS C IEC 61000-4-39probably the same standard; matched by number only
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
KS C 9610-6-1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+2 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
KS C 9610-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-4national version with changes
IEC 61000-6-7
IEC10
IEC 60730-1Automatic electrical controls - Part 1: General requirements
IEC 60730-2-9
IEC 61204-3
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements+1 national
National versions in the same scope
KS C 9040-2national version with changes
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62599-2
IEC 80601-2-77
CISPR8
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+3 national
National versions in the same scope
AS CISPR 11national version with changes
AS/NZS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 13identical to it
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
KS C 9814-1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+2 national
National versions in the same scope
AS/NZS CISPR 14.2national version with changes
KS C 9814-2national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national
National versions in the same scope
AS/NZS CISPR 15national version with changes
KS C 9815national version with changes
CISPR 20
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
CNS 15936identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsExclusion+1 national
Limits written next to it
EN 55035 (excluding 4.2.7)
National versions in the same scope
KS C 9835national version with changes
EN8
EN 12895
EN 14982
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50270
EN 50364
EN 50371
EN 55103-1
EN 55103-2
IEC 61326 series4
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements+1 national
National versions in the same scope
KS C IEC 61326-1probably the same standard; matched by number only
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.26
AS/NZS 4268
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
ISO 14982Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria
IEC 60601-1-2; IEC 60601-1-2:2007; IEC 60601-1-2:2014; KS C IEC 60601-1-2; IEC 60601-2-2; IEC 60601-2-5; IEC 60601-2-6; IEC 60601-2-10; IEC 60601-2-16; IEC 60601-2-18; IEC 60601-2-19; IEC 60601-2-20; IEC 60601-2-21; IEC 60601-2-23; IEC 60601-2-25; IEC 60601-2-27; IEC 60601-2-31; IEC 60601-2-33; IEC 60601-2-34; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-47; IEC 60601-2-50; IEC 60601-2-54; IEC 60601-2-62; IEC 60601-2-63; IEC 60601-2-65; IEC 80601-2-77; IEC/TR 60601-4-2 Edition 1.0 2016-05; IEC TS 60601-4-2:2024; ETSI EN 300 220-1; ETSI EN 300 220-2; EN 300 220-3; ETSI EN 300 328; ETSI EN 300 330; ETSI EN 300 330-1; ETSI EN 300 330-2; ETSI EN 300 440; ETSI EN 300 440-1; ETSI EN 300 440-2; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-7; KS C 3129; ETSI EN 301 489-52; ETSI EN 301 489-17; ETSI EN 301 489-23; ETSI EN 301 489-24; ETSI EN 301 489-25; ETSI EN 301 489-26; ETSI EN 301 489-28; ETSI EN 301 489-29; ETSI EN 301 489-31; ETSI EN 301 489-33; ETSI EN 302 208; ETSI EN 303 413
EN 50130-4; EN 55014-2; KS C 9814-2; EN 55035; CISPR 35; KS C 9835; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; AS/NZS 61000.6.3; EN 61000-6-3; IEC 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; IEC/CISPR 14-2; AS/NZS CISPR 14.2; IEC 61204-3; EN 62040-2; KS C 9040-2; KS X 3124; KS X 3125; KS X 3126; EN 61326-1; IEC 61326-1; KS C IEC 61326-1; IEC 61326-2-6; EN 61326-2-1; EN 61326-2-3; AIM 7351731; SEMI F47; EN 55020; EN 55103-2; IEC 61000-6-7; IEC 61547; EN 61547; IEC 62599-2; EN 60730-1; IEC 60730-1; EN 60730-2-9; EN 61800-3; IEEE C37.90.1 2012; IEEE Std C37.90.2; TCN 68-194:2000; TCN 68-195:2000; TCN 68-196:2001; TCN 68-207:2002; TCN 68-208:2002; TCN 68-209:2002; TCN 68-210:2002; IEC 60601-1-2; IEC 60601-1-2:2007; IEC 60601-1-2:2014; KS C IEC 60601-1-2; IEC 60601-2-2; IEC 60601-2-5; IEC 60601-2-6; IEC 60601-2-10; IEC 60601-2-16; IEC 60601-2-18; IEC 60601-2-19; IEC 60601-2-20; IEC 60601-2-21; IEC 60601-2-23; IEC 60601-2-25; IEC 60601-2-27; IEC 60601-2-31
ANSI C63.4a:2017; ANSI C63.4:2014; IEC 60601-1-2 Edition 4.1 2020-09; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-5: Edition 3.0 2009-07; IEC 60601-2-6 Edition 2.1 2016-04; IEC 60601-2-10 Edition 2.1 2016-04; IEC 60601-2-16 Edition 5.0 2018-4; IEC 60601-2-18: Edition 3.0 2009-08; IEC 60601-2-19 Edition 3.0 2020-09; IEC 60601-2-20 Edition 3.0 2020-09; IEC 60601-2-21 Edition 3.0 2020-09; IEC 60601-2-23 Edition 3.0 2011-02; IEC 60601-2-25 Edition 2.0 2011-10; IEC 60601-2-27 Edition 3.0 2011-03; IEC 60601-2-31 Edition 2.1 2011-09; IEC 60601-2-33 Ed. 3.2 b:2015; IEC 60601-2-34 Edition 3.0 2011-05; IEC 60601-2-36 Edition 2.0 2014-04; IEC 60601-2-37 Edition 2.1 2015; IEC 60601-2-44 Edition 3.2: 2016; IEC 60601-2-45 Edition 3.1 2015; IEC 60601-2-47 Edition 2.0 2012-02; IEC 60601-2-50 Edition 3.0 2020-09; IEC 60601-2-62 Edition 1.0 2013-07; IEC 60601-2-63 Edition 1.2 2021-05; IEC 60601-2-65 Edition 1.2 2021-05; IEC 80601-2-77 Edition 1.0 2019-07; IEC/TR 60601-4-2 Edition 1.0 2016-05; IEC TS 60601-4-2 Edition 1.0 2024-03
IEC 60601-2-33; IEC 60601-2-34; IEC 60601-2-36; IEC 60601-2-37; IEC 60601-2-44; IEC 60601-2-45; IEC 60601-2-47; IEC 60601-2-50; IEC 60601-2-54; IEC 60601-2-62; IEC 60601-2-63; IEC 60601-2-65; IEC 80601-2-77; IEC/TR 60601-4-2; IEC TS 60601-4-2:2024; ETSI EN 300 220-1; ETSI EN 300 220-2; EN 300 220-3; ETSI EN 300 328; ETSI EN 300 330; ETSI EN 300 330-1; ETSI EN 300 330-2; ETSI EN 300 440; ETSI EN 300 440-1; ETSI EN 300 440-2; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-7; KS C 3129; ETSI EN 301 489-52; ETSI EN 301 489-17; ETSI EN 301 489-23; ETSI EN 301 489-24; ETSI EN 301 489-25; ETSI EN 301 489-26; ETSI EN 301 489-28; ETSI EN 301 489-29; ETSI EN 301 489-31; ETSI EN 301 489-33; ETSI EN 302 208; ETSI EN 303 413; MSIT Public Notification 2017-10; Enforcement Decree of MSIT No. 1; Technical Requirements for Measurement of Electromagnetic Field Strength - RRA Notice 2014-2; AS/NZS 4268; RSS-102; RSS-119; RSS-127; RSS-130; RSS-132; RSS-133; RSS-134; RSS-139; RSS-191; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199; RSS-210; RSS-211; RSS-216; RSS-220; RSS-247; RSS-248; RSS-251; RSS-252; RSS-310; RSS-Gen; HKCA 1049; HKCA 1039
MSIT Public Notification 2017-10, Sep 1, 2017; Enforcement Decree of MSIT No. 1, Jul 26, 2017; Technical Requirements for Measurement of Electromagnetic Field Strength - RRA Notice 2014-2, K only (Feb. 4, 2014); AS/NZS 4268; RSS-102 measurement (RF Exposure); RSS-119; RSS-127; RSS-130; RSS-132; RSS-133; RSS-134; RSS-139; RSS-191; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199; RSS-210; RSS-211; RSS-216; RSS-220; RSS-247; RSS-248; RSS-251; RSS-252; RSS-310; RSS-Gen; HKCA 1049; HKCA 1039; QCVN 18 (2014): BTTTT; QCVN 18 (2010): BTTTT; QCVN 54 (2011): BTTTT; QCVN 54 (2020): BTTTT; QCVN 55 (2011): BTTTT; QCVN 55 (2023): BTTTT; QCVN 86 (2019: BTTTT; QCVN 96 (2015): BTTTT; QCVN 112 (2017): BTTTT; TCN 68-193:2003; TCN 68-242:2006; TCN 68-243:2006; IDA TS SRD: July 2009; IDA TS SRD Issue 1 Rev 6, May 2011; IDA TS SRD Issue 1 Rev 7, April 2013; IMDA TS SRD; IMDA TS SRD, Issue 1 (October 2016); LP0001 (2003); LP0002 (2020); LP0002 (2024); RTTE01 (2020); EN 50364; EN 50371; IEC 62233; EN 62233; EN 62311; EN 300 386; ETSI EN 300 386; EN 300 386-2; GR-1089-CORE, Issue 7 (December 2017) section 3.2.1; GR-1089-CORE, Issue 6 (2011-05) section 3.2.1; NOM-084-SCT1-2002 (sections 5.1-5.5); QCVN 86 (2015):BTTTT
QCVN 18 (2014): BTTTT; QCVN 18 (2010): BTTTT; QCVN 54 (2011): BTTTT; QCVN 54 (2020): BTTTT; QCVN 55 (2011): BTTTT; QCVN 55 (2023): BTTTT; QCVN 86 (2019: BTTTT; QCVN 96 (2015): BTTTT; QCVN 112 (2017): BTTTT; TCN 68-193:2003; TCN 68-242:2006; TCN 68-243:2006; IDA TS SRD: July 2009; IDA TS SRD Issue 1 Rev 6, May 2011; IDA TS SRD Issue 1 Rev 7, April 2013; IMDA TS SRD; IMDA TS SRD, Issue 1 (October 2016); LP0001 (2003); LP0002 (2020); LP0002 (2024); RTTE01 (2020); EN 50364; EN 50371; IEC 62233; EN 62233; EN 62311; EN 300 386; ETSI EN 300 386; EN 300 386-2; GR-1089-CORE, Issue 7 (December 2017), section 3.2.1; GR-1089-CORE, Issue 6 (2011-05), section 3.2.1; NOM-084-SCT1-2002 (sections 5.1-5.5); QCVN 86 (2015):BTTTT
47 CFR, FCC Part 15, Subpart B (using ANSI C63.4-2014); ANSI C63.4-20142; 47 CFR, FCC Part 18 (using MP-5:1986); 47 CFR, FCC Part 18 (using ANSI C63.30-2021); MP-5:1986; ICES-GEN; ICES-001; ICES-003; ICES-005; EN 12895; EN ISO 14982 (1998); ISO EN 14982 (2009); EN 50270; EN 55011; EN 55013; EN 55014-1; EN 55032; BS EN 55015; EN 55015; EN 55032; EN 55103-1; IEC/CISPR 11; AS/NZS CISPR 11 (2011); AS CISPR 11; AS/NZS CISPR 13 (2012); IEC/CISPR 14-1; AS/NZS CISPR 14.1; CISPR 15; AS/NZS CISPR 15; CISPR 32; CISPR 32: 2015 (Edition 2.0); VCCI-CISPR 32 (2016); IFT-008 (2015) with NOM-EM-016; IFT-008 (2015) with NOM-208- SCFI (2016); KS C 9811; KS C 9814-1; KS C9815; KS C 9832; KS X 3143; QCVN 118 (2018): BTTTT; TCVN 7189:2009; CNS 13438 (up to 6GHz); CNS 15936; CNS 15936: 2016; AS/NZS 61000.3.2; EN 61000-3-2; IEC 61000-3-2; KS C IEC 61000-3-2; IEC 61000-3-12; AS/NZS 61000.3.12; EN 61000-3-12; KS C IEC 61000-3-12
47 CFR, FCC Part 15, Subpart B (using ANSI C63.4-2014); ANSI C63.4-20142; 47 CFR, FCC Part 18 (using MP-5:1986); FCC Part 18 (using ANSI C63.30-2021); MP-5:1986; ICES-GEN; ICES-001; ICES-003; ICES-005; EN 12895; EN ISO 14982 (1998); ISO EN 14982 (2009); EN 50270; EN 55011; EN 55013; EN 55014-1; EN 55032; BS EN 55015; EN 55015; EN 55103-1; IEC/CISPR 11; AS/NZS CISPR 11 (2011); AS CISPR 11; AS/NZS CISPR 13 (2012); IEC/CISPR 14-1; AS/NZS CISPR 14.1; CISPR 15; AS/NZS CISPR 15; CISPR 32; CISPR 32: 2015 (Edition 2.0); VCCI-CISPR 32 (2016); IFT-008 (2015) with NOM-EM-016; IFT-008 (2015) with NOM-208- SCFI (2016); KS C 9811; KS C 9814-1; KS C9815; KS C 9832; KS X 3143; QCVN 118 (2018): BTTTT; TCVN 7189:2009; CNS 13438 (up to 6GHz); CNS 15936; CNS 15936: 2016; AS/NZS 61000.3.2; EN 61000-3-2; IEC 61000-3-2; KS C IEC 61000-3-2; IEC 61000-3-12; AS/NZS 61000.3.12; EN 61000-3-12; KS C IEC 61000-3-12; IEC 61000-3-3; AS/NZS 61000.3.3; EN 61000-3-3; KS C IEC 61000-3-3; IEC 61000-3-11; AS/NZS 61000.3.11; EN 61000-3-11; KS C IEC 61000-3-11; ANSI C63.10-2013; ANSI C63.10-2020; ANSI C63.26:2015; ANSI C63.30-2021; 47 CFR, FCC Part 15 C Unlicensed Transmitters (using ANSI C63.10-2020); 47 CFR FCC Part 15 E, U-NII without DFS (using ANSI C63.10-2020)
IEC 61000-3-3; AS/NZS 61000.3.3; EN 61000-3-3; KS C IEC 61000-3-3; IEC 61000-3-11; AS/NZS 61000.3.11; EN 61000-3-11; KS C IEC 61000-3-11; ANSI C63.10-2013; ANSI C63.10-2020; ANSI C63.26:2015; ANSI C63.30-2021; 47 CFR, FCC Part 15 C Unlicensed Transmitters (using ANSI C63.10-2020); 47 CFR FCC Part 15 E, U-NII without DFS (using ANSI C63.10-2020); 47 CFR, FCC Part 22 (cellular), Part 24, Part 25 (below 3 GHz), Part 27 (using ANSI C63.26-2015); ANSI C63.26-2015; 47 CFR, Part 22 (non-cellular), Part 90 (below 3 GHz), Part 95, Part 97 (below 3 GHz), Part 101 (below 3 GHz), (using ANSI C63.26-2015); 47 CFR, Part 96 (using ANSI C63.26-2015); ANSI/TIA 603-E (2016); TIA-102.CAAA-E-2016; ANSI/TIA 603-D (2010) and TIA-102.CAAA-D; TIA/EIA 603-D (2010); TIA/EIA 603-E (2016); IEC 61000-4-2; EN 61000-4-2; KS C IEC 61000-4-2; IEC 61000-4-3; EN 61000-4-3; KS C IEC 61000-4-3; IEC 61000-4-4; EN 61000-4-4; KS C IEC 61000-4-4; IEC 61000-4-5; EN 61000-4-5; KS C IEC 61000-4-5; IEC 61000-4-12; EN 61000-4-12; KS C IEC 61000-4-12; IEC 61000-4-6; EN 61000-4-6; KS C IEC 61000-4-6
47 CFR, FCC Part 22 (cellular); 47 CFR, FCC Part 24; 47 CFR, FCC Part 25 (below 3 GHz); 47 CFR, Part 27 (using ANSI C63.26-2015); ANSI C63.26-2015; 47 CFR, Part 22 (non-cellular); 47 CFR, Part 90 (below 3 GHz); 47 CFR, Part 95; 47 CFR, Part 97 (below 3 GHz); 47 CFR, Part 101 (below 3 GHz), (using ANSI C63.26-2015); 47 CFR, Part 96, (using ANSI C63.26-2015); ANSI/TIA 603-E (2016); TIA-102.CAAA-E-2016; ANSI/TIA 603-D (2010) and TIA-102.CAAA-D; TIA/EIA 603-D (2010); TIA/EIA 603-E (2016); IEC 61000-4-2; EN 61000-4-2; KS C IEC 61000-4-2; IEC 61000-4-3; EN 61000-4-3; KS C IEC 61000-4-3; IEC 61000-4-4; EN 61000-4-4; KS C IEC 61000-4-4; IEC 61000-4-5; EN 61000-4-5; KS C IEC 61000-4-5; IEC 61000-4-12; EN 61000-4-12; KS C IEC 61000-4-12; IEC 61000-4-6; EN 61000-4-6; KS C IEC 61000-4-6; IEC 61000-4-8; EN 61000-4-8; KS C IEC 61000-4-8; EN 61000-4-9; IEC 61000-4-9; KS C IEC 61000-4-9; IEC 61000-4-11; EN 61000-4-11; IEC 61000-4-34; EN 61000-4-34; KS C IEC 61000-4-11; KS C IEC 61000-4-34; IEC 61000-4-39; EN 61000-4-39; KS C IEC 61000-4-39
IEC 61000-4-8; EN 61000-4-8; KS C IEC 61000-4-8; EN 61000-4-9; IEC 61000-4-9; KS C IEC 61000-4-9; IEC 61000-4-11; EN 61000-4-11; IEC 61000-4-34; EN 61000-4-34; KS C IEC 61000-4-11; KS C IEC 61000-4-34; IEC 61000-4-39; EN 61000-4-39; KS C IEC 61000-4-39; EN 50130-4; EN 55014-2; KS C 9814-2; EN 55035 (excluding 4.2.7); CISPR 35 (2016) (excluding 4.2.7); KS C 9835; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; AS/NZS 61000.6.3; EN 61000-6-3; IEC 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; IEC/CISPR 14-2; AS/NZS CISPR 14.2; IEC 61204-3; EN 62040-2; KS C 9040-2; KS X 3124; KS X 3125; KS X 3126; EN 61326-1; IEC 61326-1; KS C IEC 61326-1; IEC 61326-2-6; EN 61326-2-1; EN 61326-2-3; AIM 7351731; SEMI F47; EN 55020; EN 55103-2; IEC 61000-6-7; IEC 61547; EN 61547; IEC 62599-2; EN 60730-1; IEC 60730-1; EN 60730-2-9; EN 61800-3; IEEE C37.90.1 2012; IEEE Std C37.90.2; TCN 68-194:2000; TCN 68-195:2000; TCN 68-196:2001; TCN 68-207:2002; TCN 68-208:2002; TCN 68-209:2002; TCN 68-210:2002
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; ANSI C63.26-2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
13 lines
ISO/IEC 17025
Active751.07
The scope document we hold says it was valid until 2026-05-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Location
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- CKC Laboratories, Inc.Mariposa, CA · ~2,765 kmA2LAShares 4 accredited test methodsAS/NZS 4268IEC 60601-1-2IEC 61000-3-3
- EzurioCedarburg, WI · ~131 kmA2LAShares 3 accredited test methodsANSI C63.4:2014ETSI EN 300 220-1ICES-001
- EUROFINS ELECTRICAL AND ELECTRONIC TESTING NAAustin, TX · ~1,588 kmA2LAShares 3 accredited test methodsANSI C63.4:2014EN 50130-4ICES-001
- TUV Rheinland of North AmericaPleasanton, CA · ~2,927 kmA2LAShares 3 accredited test methodsANSI C63.26-2015ANSI C63.4:2014IEC 60601-1-2
- Intertek Testing Services NAFridley, MN · ~547 kmA2LAShares 2 accredited test methodsANSI C63.4:2014EN 50130-4
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.