What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 14 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM10
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM B557
ASTM B918
ASTM E8Standard Test Methods for Tension Testing of Metallic Materials
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E92Standard Test Methods for Vickers Hardness and Knoop Hardness of Metallic Materials
ASTM E384Standard Test Method for Microindentation Hardness of Materials
ASTM E1251
ASTM G85
ASTM G110
ISO3
ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
ISO 11846Corrosion of metals and alloys - Determination of resistance to intergranular corrosion of solution heat-treatable aluminium alloys
ISO 11997-1Paints and varnishes - Determination of resistance to cyclic corrosion conditions - Part 1: Wet (salt fog)/dry/humid
Other standards1
VDA 238
ASTM B557/B557M; ASTM E8/E8M; BS EN ISO 6892-1; JIS Z 2241; VDA 238-100; JIS Z 2248; ASTM E18; ASTM E384; ASTM E92; ASTM E1251; AMS 27502; ASTM B918/B918M; CQI-9; ASTM B117; ASTM G85 A3; ISO 11997-1; JIS Z 2371; ISO 11846; ASTM G110
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
2 lines
ISO/IEC 17025
Active2043.01
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 2043.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM B557/B557M; ASTM E8/E8M; BS EN ISO 6892-1; JIS Z 2241; VDA 238-100; JIS Z 2248; ASTM E18; ASTM E384; ASTM E92; ASTM E1251; AMS 27502; ASTM B918/B918M; CQI-9; ASTM B117; ASTM G85 A3; ISO 11997-1; JIS Z 2371; ISO 11846; ASTM G110 | Metal | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
HYDRO ALUMINUM TECHNOLOGY CENTER (HATC)
Cassopolis, MI
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 25th day of March 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2043.01
Valid to March 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- ICC Evaluation ServiceElkhart, IN · ~21 kmA2LAShares 2 accredited methods and materialsASTM E8/E8MMetal
- Veltec LaboratoriesTaylor, MI · ~229 kmA2LAShares 2 accredited methods and materialsASTM E8/E8MMetal
- Touchstone Testing Laboratory, LLCTriadelphia, WV · ~497 kmA2LAShares 2 accredited methods and materialsASTM E8/E8MMetal
- Standard MechanicsStarkville, MS · ~971 kmA2LAShares 2 accredited methods and materialsASTM E8/E8MMetal
- Innovative Test SolutionsSchenectady, NY · ~996 kmA2LAShares 2 accredited methods and materialsASTM E8/E8MMetal
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.