Trescal, Inc. - Pleasanton, CA
1047 Serpentine Lane, Suite 500, 94566, Pleasanton, CA, United States
Visit website- Scope lines
- 15
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 2220.01 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 20 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 2 of 14
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
DC Voltage3 – Generate
(0 to 329.9999) µV
330 µV to 3.299 999 V
(3.3 to 32.999 99) V
(33 to 329.9999) V
(330 to 1000) V
0.84 µV + 16 nV/mV
17 µV + 6 µV/V
88 µV + 7 µV/V
0.55 mV + 14 µV/V
2.6 mV + 14 µV/V
Fluke 5522A
DC Voltage3 – Measure
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
0.33 µV + 17 µV/V
0.52 µV + 8 µV/V
8.8 µV + 8.1 µV/V
35 µV + 10 µV/V
1.2 mV + 11 µV/V
Agilent 3458A
DC Current3 – Generate
(0 to 329.999) µ A
330 µA to 3.299 99 mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
330 mA to 1.099 99 A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
16 nA + 0.12 nA/µA
40 nA + 78 nA/mA
0.2 µA + 78 nA/mA
2 µA + 78 nA/mA
33 µA + 0.16 mA/A
0.36 mA + 0.3 mA/A
0.48 mA + 0.38 mA/A
9.1 mA + 0.78 mA/A
Fluke 5522A
DC Current3 – Measure
(0 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
41 pA + 89 µA/A
70 pA + 21 µA/A
0.4 nA + 19 µA/A
0.83 nA + 17 µA/A
5.8 nA + 19 µA/A
0.053 µA + 16 µA/A
0.53 µA + 32 µA/A
10 µA + 100 µA/A
Agilent 3458A
DC High Voltage –
Measure
(1 to 10) kV
0.037 %
Vitrek 4700
AC High Voltage –
Measure
(1 to 10) kV, 60 Hz
0.14 %
Vitrek 4700 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 3 of 14
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance3 – Generate
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(330 to 1099.999) Ω
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(330 to 1099.999) kΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
1.1 mΩ + 25 µΩ/Ω
1.4 mΩ + 31 µΩ/Ω
2.6 mΩ + 18 µΩ/Ω
4.4 mΩ + 23 µΩ/Ω
9.7 mΩ + 24 µΩ/Ω
42 mΩ + 24 µΩ/Ω
98 mΩ + 24 µΩ/Ω
0.42 Ω + 24 µΩ/Ω
0.97 Ω + 24 µΩ/Ω
8.3 Ω + 25 µΩ/Ω
14 Ω + 25 µΩ/Ω
90 Ω + 47 µΩ/Ω
0.39 kΩ + 0.1 mΩ/Ω
4.2 kΩ + 0.19 mΩ/Ω
15 kΩ + 0.39 mΩ/Ω
0.34 MΩ + 2.3 mΩ/Ω
4.2 MΩ + 12 mΩ/Ω
Fluke 5522A
Resistance3 – Generate,
Fixed Point, Calibrate
Thermometer DRO
25 Ω
75 Ω
100 Ω
200 Ω
400 Ω
40 µΩ
0.11 mΩ
0.14 mΩ
0.39 mΩ
0.61 mΩ
Hart 5420-25
MI 9331-75
Hart 5420-100
Hart 5420-200
Hart 5420-400
Resistance3 – Measure
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
55 µΩ + 15 µΩ/Ω
0.52 mΩ + 13 µΩ/Ω
0.53 mΩ + 10 µΩ/Ω
5.3 mΩ + 10 µΩ/Ω
53 mΩ + 11 µΩ/Ω
2.3 Ω + 17 µΩ/Ω
0.1 kΩ + 55 µΩ/Ω
1 kΩ + 0.52 mΩ/Ω
10 kΩ + 5.1 mΩ/Ω
Agilent 3458A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 4 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(1 to 32.999) mV
(33 to 329.999) mV
330 mV to 3.299 99 V
(3.3 to 32.9999) V
(33 to 329.999) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
5.7 µV + 0.62 µV/mV
6.1 µV + 0.1 µV/mV
6.1 µV + 0.14 µV/mV
8.1 µV + 0.71 µV/mV
16 µV + 2.6 µV/mV
46 µV + 6.2 µV/mV
53 µV + 6 µV/mV
20 µV + 0.22 µV/mV
27 µV + 77 nV/mV
17 µV + 0.11 µV/mV
37 µV + 0.27 µV/mV
50 µV + .061 µV/mV
0.11 mV + 1.5 µV/mV
0.15 mV + 1.4 µV/mV
0.15 mV + 0.22 mV/V
0.13 mV + 0.11 mV/V
0.13 mV + 0.14 mV/V
0.21 mV + 0.21 mV/V
0.39 mV + 0.51 mV/V
1.1 mV + 1.9 mV/V
1.8 mV + 1.7 mV/V
1.8 mV + 0.22 mV/V
1.6 mV + 99 µV/V
2 mV + 0.16 mV/V
2.4 mV + 0.24 mV/V
5 mV + 0.66 mV/V
16 mV + 0.12 mV/V
18 mV + 0.14 mV/V
19 mV + 0.17 mV/V
48 mV + 0.16 mV/V
93 mV + 1.5 mV/V
96 mV + 0.22 mV/V
85 mV + 0.18 mV/V
96 mV + 0.22 mV/V
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 5 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
(0.1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.0061 mV + 0.0003 mV/mV
0.0041 mV + 0.0002 mV/mV
0.0042 mV + 0.0003 mV/mV
0.0049 mV + 0.001 mV/mV
0.009 mV + 0.005 mV/mV
0.045 mV + 0.04 mV/mV
0.012 mV + 0.000 07 mV/mV
0.0027 mV + 0.000 07 mV/mV
0.011 mV + 0.000 14 mV/mV
0.012 mV + 0.0003 mV/mV
0.017 mV + 0.0008 mV/mV
0.047 mV + 0.003 mV/mV
0.12 mV + 0.01 mV/mV
3.8 mV + 0.01 mV/mV
0.000 12 V + 0.000 07 V/V
0.0001 V + 0.000 07 V/V
0.000 11 V + 0.000 14 V/V
0.000 12 V + 0.0003 V/V
0.000 17 V + 0.0008 V/V
0.000 47 V + 0.003 V/V
0.0012 V + 0.010 V/V
0.038 V + 0.015 V/V
0.0012 V + 0.000 07 V/V
0.001 V + 0.000 07 V/V
0.001 V + 0.000 14 V/V
0.0012 V + 0.0003 V/V
0.0017 V + 0.0008 V/V
0.0047 V + 0.003 V/V
0.012 V + 0.01 V/V
0.38 V + 0.015 V/V
0.013 V + 0.0002 V/V
0.011 V + 0.0002 V/V
0.011 V + 0.0002 V/V
0.013 V + 0.000 35 V/V
0.021 V + 0.0012 V/V
0.057 V + 0.004 V/V
0.17 V + 0.015 V/V
0.098 V + 0.0004 V/V
0.084 V + 0.0004 V/V
0.098 V + 0.0006 V/V
0.14 V + 0.0012 V/V
0.27 V + 0.003 V/V
Agilent 3458A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 6 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(29 to 329.99) µA
330 µA to 3.2999 mA
(3.3 to 32.999) mA
(33 to 329.99) mA
330 mA to 1.099 99 A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.14 µA + 1.5 nA/µA
0.13 µA + 1.1 nA/µA
0.13 µA + 0.92 nA/µA
0.2 µA + 2.3 nA/µA
0.34 µA + 6.2 nA/µA
0.68 µA + 1.2 nA/µA
0.77 µA + 1.5 µA/mA
0.59 µA + 0.93 µA/mA
0.55 µA + 0.73 µA/mA
0.78 µA + 1.5 µA/mA
2.9 µA + 1.5 µA/mA
3.3 µA + 7.7 µA/mA
7.5 µA + 1.4 µA/mA
5.3 µA + 0.66 µA/mA
4.5 µA + 0.27 µA/mA
5.2 µA + 0.58 µA/mA
8.3µA + 1.5 µA/mA
14 µA + 3.1 µA/mA
75 µA + 1.4 µA/mA
55 µA + 0.66 µA/mA
47 µA + 0.26 µA/mA
75 µA + 0.75 µA/mA
0.13 mA + 1.5 µA/mA
0.26 mA + 3.1 µA/mA
0.6 mA + 1.3 mA/A
0.33 mA + 0.31 mA/A
2.3 mA + 4.6 mA/A
10 mA + 19 mA/A
1.6 mA + 1.5 mA/A
0.65 mA + 0.66 mA/A
5.9 mA + 4.7 mA/A
25 mA + 19 mA/A
3.3 mA + 0.72 mA/A
4.1 mA + 0.95 mA/A
71 mA + 23 mA/A
15 mA + 1.7 mA/A
18 mA + 1.8 mA/A
0.26 A + 23 mA/A
Fluke 5520A | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 7 of 14
Parameter/Range
Frequency
CMC2 ,4 (±)
Comments
AC Current3 – Measure
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
57 nA + 4 mA/A
45 nA + 1.5 mA/A
40 nA + 0.64 mA/A
0.000 43 mA + 0.0041 mA/mA
0.000 31 mA + 0.0016 mA/mA
0.000 26 mA + 0.000 67 mA/mA
0.000 25 mA + 0.000 37 mA/mA
0.000 26 mA + 0.000 67 mA/mA
0.000 63 mA + 0.0042 mA/mA
0.0018 mA + 0.0056 mA/mA
0.0024 mA + 0.0041 mA/mA
0.0023 mA + 0.0016 mA/mA
0.0023 mA + 0.000 67 mA/mA
0.0023 mA + 0.000 37 mA/mA
0.0023 mA + 0.000 67 mA/mA
0.0045 mA + 0.0041 mA/mA
0.016 mA + 0.0056 mA/mA
0.042 mA + 0.004 mA/mA
0.03 mA + 0.0015 mA/mA
0.025 mA + 0.0006 mA/mA
0.024 mA + 0.0003 mA/mA
0.025 mA + 0.0006 mA/mA
0.062 mA + 0.004 mA/mA
0.18 mA + 0.0055 mA/mA
0.00042 A + 0.0041 A/A
0.0003 A + 0.0017 A/A
0.000 26 A + 0.0009 A/A
0.000 27 A + 0.0011 A/A
0.000 37 A + 0.0031 A/A
0.000 92 A + 0.01 A/A
Agilent 3458A | 5 to 100 µA |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 8 of 14
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
0.4 to 1.0999) nF
(1.1 to 3.299) nF
(3.3 to 10.999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.99) nF
(0.33 to 1.0999) µF
(1.1 to 3.2999) µF
(3.3 to 10.999) µF
(11 to 32.999) µF
(33 to 109.99) µF
(110 to 329.99) µF
(0.33 to 1.0999) mF
(1.1 to 3.2999) mF
(3.3 to 10.999) mF
(11 to 32.999) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
Up to 50 Hz
Up to 20 Hz
Up to 6 Hz
Up to 2 Hz
Up to 0.6 Hz
Up to 0.2 Hz
8.5 pF + 3.8 pF/nF
9.4 pF + 3.9 pF/nF
12 pF + 3.9 pF/nF
15 pF + 2 pF/nF
0.1 nF + 1.9 pF/nF
0.14 nF + 1.9 pF/nF
0.45 nF + 1.9 pF/nF
1.4 nF + 1.9 nF/µF
4.4 nF + 1.9 nF/µF
14 nF + 1.9 nF/µF
58 nF + 3.1 nF/µF
0.19 µF + 3.5 nF/µF
0.62 µF + 3.5 nF/µF
1.9 µF + 3.5 µF/mF
6.8 µF + 3.4 µF/mF
38 µF + 2.4 µF/mF
87 µF + 5.8 µF/mF
0.36 mF + 8.5 µF/mF
Fluke 5520A
Capacitance – Measure
See table below
(CMC’s can be
interpolated between
cardinal frequencies)
See table below
IET DE-6000
LCR meter
100 Hz 120 Hz 1 kHz 10 kHz 100 kHz
Up to 2000 pF ---- ---- 2.3 % 0.47 % 0.87 %
(2 to 20) nF 2.3 % 2.3 % 0.24 % 0.36 % 0.72 %
(20 to 200) nF 0.36 % 0.36 % 0.24 % 0.36 % 0.72 %
200 nF to 2 µF 0.37 % 0.37 % 0.26 % 0.72 % 2.4 %
(2 to 20) µF 0.36 % 0.36 % 0.72 % 1.5 % 3.8 %
(20 to 200) µF 0.72 % 0.72 % 1.3 % 3.8 %
200 µF to 2 mF 1.3 % 1.3 % 1.8 % ---- ---- | ||
| 9 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 9 of 14
Parameter/Equipment
Range CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicators3
Type B
Type C
Type E
Type J
Type K
Type N
(250 to < 350) °C
(350 to < 445) °C
(445 to < 580) °C
(580 to < 780) °C
(750 to < 1000) °C
(1000 to 1820) °C
(0 to < 250) °C
(250 to < 1000) °C
(1000 to < 1500) °C
(1500 to < 1800) °C
(1800 to < 2000) °C
(2000 to < 2250) °C
(2250 to 2315) °C
(-270 to < -245) °C
(-245 to < -195) °C
(-195 to < -155) °C
(-155 to < -90) °C
(-90 to < 15) °C
(15 to < 890) °C
(890 to 1000) °C
(-210 to < -180) °C
(180 to < -120) °C
(-120 to < -50) °C
(-50 to < 990) °C
(990 to 1200) °C
(-270 to < -255) °C
(-255 to < -195) °C
(-195 to < -115) °C
(-115 to < -55) °C
(-55 to < 1000) °C
(1000 to 1372) °C
(-270 to < -260) °C
(-260 to < -200) °C
(-200 to < -140) °C
(-140 to < -70) °C
(-70 to < 25) °C
(25 to < 160) °C
(160 to 1300) °C
0.95 °C
0.74 °C
0.58 °C
0.46 °C
0.38 °C
0.3 °C
0.21 °C
0.17 °C
0.19 °C
0.22 °C
0.24 °C
0.3 °C
0.33 °C
1.2 °C
0.18 °C
0.1 °C
0.082 °C
0.073 °C
0.063 °C
0.07 °C
0.12 °C
0.1 °C
0.083 °C
0.073 °C
0.07 °C
2.2 °C
0.7 °C
0.12 °C
0.092 °C
0.073 °C
0.083 °C
5 °C
1 °C
0.23 °C
0.16 °C
0.13 °C
0.11 °C
0.1 °C
Ectron 1140A | to 1820 °C |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 10 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicators3
– (cont)
Type R
Type S
Type T
(-50 to < -30) °C
(-30 to < 45) °C
(45 to < 160) °C
(160 to < 380) °C
(380 to < 775) °C
(775 to 1768) °C
(-50 to < -30) °C
(-30 to < 45) °C
(45 to < 105) °C
(105 to < 310) °C
(310 to < 615) °C
(615 to 1768) °C
(-270 to < -255) °C
(-255 to < -240) °C
(-240 to < -210) °C
(-210 to < -150) °C
(-150 to < -40) °C
(-40 to < 100) °C
(100 to 400) °C
0.65 °C
0.55 °C
0.41 °C
0.31 °C
0.27 °C
0.23 °C
0.62 °C
0.56 °C
0.41 °C
0.34 °C
0.3 °C
0.27 °C
1.8 °C
0.49 °C
0.3 °C
0.18 °C
0.12 °C
0.085 °C
0.08 °C
Ectron 1140A
III. Fluid Quantities
Parameter/Equipment
Range CMC2, 5 (±)
Comments
Air Flow Rate – Measure
(10 to 100) sccm
(0.1 to 1) slm
(1 to 10) slm
(10 to 100) slm
(40 to 400) slm
0.41 % of rdg
0.41 % of rdg
0.41 % of rdg
0.41 % of rdg
0.41 % of rdg
DHI Molbloc
Air Flow Rate – Measure3
(5 to 500) sccm
500 sccm to 50 slm
0.52 % of rdg
0.57 % of rdg
Sierra Instruments primary
gas flow calibrator | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 11 of 14
IV. Mechanical
Parameter/Equipment
Range CMC2, 5, 7 (±)
Comments
Torque Wrenches
4 ozf-in to 250 lbf-ft
0.37 % of rdg
Torque transducers
Pressure – Measure3
± (0 to 7.5) inH2O
± (7.5 to 30) inH2O
Up to 15 psia
(-14.5 to 0) psig
(0 to 40) psig
(40 to 100) psig
(100 to 200) psig
(200 to 500) psig
(0 to 1000) psig
0.0004 inH2O
0.0064 % of rdg
0.002 psi
0.002 psi
0.002 psi
0.0055 % of rdg
0.01 psi
0.005 % of rdg
0.58 psi
Ruska 7250LP
Ruska 7252i
Ashcroft pressure module
Scales3
Up to 1200 lbs
0.82R
NIST F Class weights
Balances3
Up to 45 kg
Matrix value x R
Class 1 weights
Unit Under Test Resolution
0.000 01 g 0.0001 g 0.001 g 0.01 g 0.1 g 1 & 10 g
1 mg
2 mg
5 mg
10 mg
20 mg
50 mg 0.85
100 mg
200 mg 0.83
500 mg 0.86
1 g 0.83
2 g 0.87 0.82
5 g 0.91
10 g 1.1
20 g
50 g 1.2
100 g 2.0
200 g 6.7 1.1
500 g 1.2
1 kg 1.8
2 kg 9.5 1.3
5 kg 1.5 0.83
10 kg 5.8 | 4 to 250 lbf-ft |
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 12 of 14
Parameter/Equipment
Range CMC2, 7 (±)
Comments
Balances3 (cont)
Up to 45 kg
Matrix value x R
Class 1 weights
Unit Under Test Resolution
0.000 01 g 0.0001 g 0.001 g 0.01 g 0.1 g 1 & 10 g
20 kg
0.82
30 kg
40 kg
45 kg
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Relative Humidity –
Measuring
Equipment
(10 to 95) % RH @
(0 to 70) °C
(0 to 70) °C
0.51 % RH + 0.000 39 % RH/% RH
+ 0.000 051 % RH/°C
0.074 °C
Thunder
Scientific 2500
generator
Relative Humidity –
Measure
3
(11 to 90) % RH
(90 to 95) % RH
1.4 % RH
2.1 % RH
Vaisala MI70
w/ HMP76B
Temperature3 –
Measure
(-197 to < 0) °C
(0 to 660) °C
(660 to 960) °C
0.0037 °C - 0.000 000 45 x
ΔTChange from -197
0.0027 °C + 0.000 0002 x
ΔTChange from 0
0.42 °C + 0.000 39 x ΔTChange from 660
1595A
thermometer,
5699 PRT
Type “S”
thermocouple
Temperature3 –
Measuring
Equipment
-195.7 °C
(-80 to 660) °C
(660 to 770) °C
(770 to 1100) °C
0.0046 °C
0.0042 °C + 0.000 019 x ΔTChange
from -80
0.63 °C + 0.000 75 x ΔTChange from 770
0.51 °C + 0.000 68 x ΔTChange from -80
1595A
thermometer,
5699 PRT, type
S thermocouple
probe, LN2
comparator,
calibration
wells/baths | to 45 kg |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 13 of 14
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Frequency –
Measuring
Equipment
10 mHz to 2 MHz
5.8 µHz + 2.9 µHz/Hz
Fluke 5520A
Stopwatches, Timers
& Timing Devices
Time Base
Method
Comparison
± (0 to 19.99) sec/day
Up to 86 400 sec
0.037 sec/day
0.0053 %
Timometer
Chronograph
Rotational Speed3
Optical
Contact
(Mechanical)
(5 to 200 000) rpm
(5 to 20 000) rpm
0.18 %
0.066 %
Monarch PLT200
____________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being
larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification. | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 14 of 14
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 In the statement of CMC, R is the resolution of the unit under test and percentages are percent of reading
unless otherwise indicated. | ||
| 15 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- HCT AmericaMilpitas, CA · ~26 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - Silicon ValleySanta Clara, CA · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Silicon Valley, CASan Jose, CA · ~36 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Rice Lake Weighing Systems (Formerly Heusser Neweigh)Concord, CA · ~38 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- International Process SolutionsSan Carlos, CA · ~38 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.