Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 2789.02 · 6 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2789.02) Revised 5/29/2025 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 IKONIX ASIA SDN. BHD. Block D3, Unit D3-5-1, Jalan PJU 1a/46, Dana 1 Commercial Centre, 47301 Petaling Jaya, Selangor, Malaysia 47301 Jason Pei Phone: +603 7842 9168 https://www.ikonix.com/ CALIBRATION Valid To: August 31, 2026 Certificate Number: 2789.02 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements) accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Electrical – DC / Low Frequency Parameter/Range Frequency CMC 2, 6, 7 (±) Comments AC Voltage – Measure (1 to 100) mV 100 mV to 1 V (1 to 750) V (10 to 30) V (30 to 100) V (100 to 300) V (300 to 1000) V (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) mV 100 mV to 1 V (1 to 10) V 10 Hz to 20 kHz (40 to 1000) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz 0.14 % + 0.02 mV 0.09 % + 0.2 mV 0.064 % + 0.04 V 0.17 % + 0.03 V 0.09 % + 0.1 V 0.08 % + 0.3 V 0.01 % + 1 V 0.01 % + 2.0 µV 0.018 % + 20 µV 0.018 % + 0.2 mV 0.024 % + 2.0 mV 0.018 % + 2.0 µV 0.018 % + 20 µV 0.018 % + 0.2 mV 0.036 % + 2.0 µV 0.037 % + 20 µV 0.037 % + 0.2 mV Keysight 34465A direct read N4L PPA530 direct read HP 3458A direct read for wideband leakage
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2789.02) Revised 5/29/2025 Page 2 of 5 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage – Measure (cont) (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) mV 100 mV to 1 V (1 to 10) V (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.093 % + 2.0 µV 0.093 % + 20 µV 0.093 % + 0.2 mV 0.34 % + 10 µV 0.35 % + 0.1 mV 0.35 % + 1 mV 1.2 % + 10 µV 1.2 % + 0.1 mV 1.2 % + 1.0 mV HP 3458A direct read for wideband leakage AC High Voltage – Measure (1 to 2) kV (2 to 19.5) kV (50, 60) Hz (50, 60) Hz 0.58 % + 0.4 V 0.56 % + 20 V Keysight 34465A & HV Dividers AC Current – Measure 10 to 100 µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) mA (1 to 10) mA (0.1 to 1) mA (1 to 10) mA (0.1 to 1) mA (1 to 10) mA (30 to 300) mA (0 to 300) µA (0.3 to 20) mA (20 to 100) mA (45 to 1000) Hz (45 to 5000) Hz (45 to 5000) Hz (45 to 5000) Hz (5 to 20) kHz (5 to 20) kHz (20 to 50) kHz (20 to 50) kHz (50 to 100) kHz (50 to 100) kHz (50 to 60) Hz (65 to 800) Hz (65 to 800) Hz (65 to 800) Hz 0.11 % 0.12 % 0.094 % 0.14 % 0.099 % 0.077 % 0.51 % 0.29 % 0.82 % 0.56 % 0.6 % + 0.3 mA 0.6 % + 0.03 μA 0.59 % + 3 μA 2.7 % + 0.3 mA HP 3458A Gossen 249A Gossen 249A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2789.02) Revised 5/29/2025 Page 3 of 5 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Current – Measure (cont) (0.3 to 1) A (1 to 3) A (3 to 10) A (10 to 20) A (20 to 60) A (1 to 60) A (50, 60) Hz (50, 60) Hz (50, 60) Hz (50, 60) Hz (50, 60) Hz (50, 60) Hz 0.24 % + 1 mA 0.17 % + 3 mA 0.09 % + 10 mA 0.2 % + 20 mA 110 mA 0.13 A Line test with N4L PPA530 direct read N4L PPA530 with Voltech CT1000 Current Transformer Ground bond test with Keysight 34465A & Reidon 100 A Shunt Parameter/Equipment Range CMC2, 6, 7 (±) Comments DC Voltage – Measure (1 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V 0.025 % + 3.5 μV 0.026 % + 4 μV 0.096 % + 40 μV 0.043 % + 600 μV 0.02 % + 60 mV 0.0015 % 0.0011 % 0.0011 % 0.0013 % Keysight 34465A direct read HP 3458A direct read for DC line leakage test DC High Voltage – Measure (1 to 6) kV (6 to 19.5) kV 0.012 kV 0.049 kV Keysight 34465A & HV Dividers DC Current – Measure Up to 100 nA (0.1 to 1) µA (1 to 10) µA 0.17 mA/A + 0.04 nA 55 µA/A + 0.04 nA 56 µA/A + 0.1 nA HP 3458A
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2789.02) Revised 5/29/2025 Page 4 of 5 Parameter/Equipment Range CMC2, 6, 7 (±) Comments DC Current – Measure (cont) (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (30 to 300) mA (1 to 40) A 33 µA/A + 0.8 nA 48 µA/A + 5.0 nA 0.25 mA/A + 50 nA 0.031 % + 0.5 µA 0.072 % + 35 μA 0.3 % HP 3458A Gossen 249A Ground bond test with HP 3458A & Reidon 100 A Shunt Resistance – Generate (10 to 600) mΩ (0.01 to 0.1) Ω (0.1 to 100) Ω (100 to 1000) Ω (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 1000) MΩ 0.12 % 3.0 % + 15 mΩ 0.31 % + 15 mΩ 0.12 % + 15 mΩ 0.10 % 0.12 % 0.12 % 0.12 % 1.2 % Custom load fixture Decade Resistance Box Decade Resistance Box Custom built resistance load fixture Resistance – Measure (0.010 to 10) Ω (10 to 100) Ω (100 to 1000) Ω (1 to 10) kΩ (10 to 100) kΩ (100 to 1000) kΩ (1 to 10) MΩ (10 to 100) MΩ 64 µΩ/Ω + 50 µΩ 14 µΩ/Ω + 0.5 mΩ 18 µΩ/Ω + 0.5 mΩ 18 µΩ/Ω + 5.0 mΩ 19 µΩ/Ω + 50 mΩ 78 µΩ/Ω + 2.0 Ω 0.018 % + 100 Ω 0.59 % + 1.0 kΩ HP 3458A Power3 – Measure (10 to 4000) W Power Factor 0.250 0.700 1.000 (50, 60) Hz (50, 60) Hz 1.4 % 0.0026 0.0023 0.0023 N4L PPA530 Power factor is computed based on measured real power divided by apparent power. Pf = W/VA
10 to 4000 W
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2789.02) Revised 5/29/2025 Page 5 of 5 II. Time & Frequency Parameter/Equipment Range CMC 2, 4, 7 (±) Comments Frequency – Measure 100 mV to 750 V 20 Hz to 300 kHz 0.02 % Keysight 34465A ___________________________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 CMC is computed based on direct reading in W. 4 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 In the statement of CMC, percentages are per centage of reading, unless otherwise indicated.
0.1 to 750 V
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited IKONIX ASIA SDN. BHD. Selangor, MALAYSIA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 21st day of August 2024. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2789.02 Valid to August 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.