Italy

TUV Rheinland Italia

via Enrico Mattei, 3, Pogliano Milanese, 20005, Italy, Pogliano Milanese, Italy

A2LA 7467.01ISO/IEC 17025Register refreshed 2026-11-20
Part of the TÜV Rheinland group: 51 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 7467.01 · 15 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; R205-to 25 mm
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 2 of 14 II. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate, Ammeters, Generators, Probes3 (100 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.0999) A (1.1 to 2.999) A (3 to 10.999) A (11 to 20.5) A (20 to 500) A (500 to 3000) A 45 Hz to 1 kHz 0.13 % + 0.10 µA 0.1 % + 0.30 µA 0.04 % + 3.0 µA 0.04 % + 28 µA 0.07 % + 0.22 mA 0.08 % + 0.2 mA 0.09 % + 2.8 mA 0.17 % + 5.4 mA 0.078 % + 1 mA 0.14 % + 14 mA Fluke 8508A, Fluke 5522A, Fluke 52120A, Fluke coil 3kA AC Current – Generate, Ammeters, Generators, Probes3 (100 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.0999) A (1.1 to 2.999) A (3 to 10.999) A (11 to 20.5) A (20 to 500) A (500 to 3000) A (1 to 3) kHz 0.3 % + 0.15 µA 0.2 % + 0.30 µA 0.08 % + 3 µA 0.10 % + 54 µA 0.6 % + 1 mA 3 % + 2.8 mA 3 % + 5.4 mA 0.17 % + 5.4 mA 0.6 % + 1 mA 0.62 % + 14 mA Fluke 8508A, Fluke 5522A, Fluke 52120A, Fluke coil 3kA AC Current – Generate, Ammeters, Generators, Probes3 (100 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.0999) A (1.1 to 2.999) A (3 to 10.999) A (11 to 20.5) A (3 to 5) kHz 0.3 % + 0.15 µA 0.2 % + 0.30 µA 0.08 % + 3 µA 0.10 % + 54 µA 0.6 % + 1 mA 0.6 % + 1 mA 3 % + 2.8 mA 3 % + 5.4 mA Fluke 8508A, Fluke 5522A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 3 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate, Ammeters, Generators, Probes3 (100 to 329.99) µA (0.33 to 3.2999) mA (3.33 to 32.99) mA (33 to 329.99) mA (0.33 to 1.0999) A (1.1 to 2.999 A) (5 to 10) kHz 0.8 % + 0.20 µA 0.5 % + 0.40 µA 0.2 % + 3.7 µA 0.2 % + 100 µA 2.5 % + 5 mA 2.5 % + 5 mA Fluke 8508A, Fluke 5522A AC Current – Generate, Ammeters, Generators, Probes3 (100 to 329.99) µA (0.33 to 3.299) mA (3.33 to 32.99) mA (33 to 329.99) mA (10 to 30) kHz 1.6 % + 0.40 µA 1 % + 0.7 µA 0.4 % + 4.9 µA 0.40 % + 200 µA Fluke 8508A, Fluke 5522A AC Voltage – Generate, Voltmeters, Generators3 (0.100 to 33) mV (33 to 329) mV (0.33 to 3.29) V (3.3 to 32.99) V (33 to 329.99) V (330 to 1020) V 45 Hz to 20 kHz 45 Hz to 10 kHz 320 µV/V + 8.5 µV 300 µV/V + 24 µV 310 µV/V + 0.06 mV 250 µV/V + 0.64 mV 200 µV/V + 23 mV 310 µV/V + 25 mV Fluke 8508A, Fluke 5522A AC Voltage – Generate, Voltmeters, Generators3 (0.100 to 33) mV (33 to 329) mV (0.33 to 3.29) V (3.3 to 32.99) V (33 to 329.99) V (20 to 50) kHz 1100 µV/V + 21 µV 430 µV/V + 200 µV 390 µV/V + 0.21 mV 430 µV/V + 2.1 mV 270 µV/V + 42m V Fluke 8508A, Fluke 5522A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 4 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current– Generate, Ammeters, Generators (60 to 329) µA (0.33 to 2.999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.099) A (1.1 to 2.999) A (3 to 10.99) A (11 to 20.50) A (20 to 200) A (200 to 1000) A 150 µA/A + 20 nA 100 µA/A + 64 nA 100 µA/A + 840 nA 130 µA/A + 16 µA 220 µA/A + 43 µA 430 µA/A + 400 µA 540 µA/A + 640 µA 1000 µA/A + 850 µA 61 µA/A + 0.42 mA 0.35 mA/A + 5.3 mA Fluke 8508A, Fluke 5522A, Fluke 52120A, Fluke coil 3kA DC Voltage – Generate, Voltmeters, Generators (0.1 to 3.2999) mV (0.33 to 3.2999) V (3.3 to 32.999) V (33 to 329.99) V (330 to 1020) V 20 µV/V + 1.1 µV 11 µV/V + 4.9 µV 12 µV/V + 49 µV 18 µV/V + 0.56 mV 18 µV/V + 2.5 mV Fluke 8508A, Fluke 5522A Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate, Voltmeters, Generators3 (0.100 to 33) mV (33 to 329) mV (0.33 to 3.29) V (3.3 to 32.99) V (33 to 329.99) V (50 to 100) kHz 3500 µV/V + 23 µV 840 µV/V + 200 µV 740 µV/V + 0.24 mV 930 µV/V + 2.7 mV 2000 µV/V + 160 mV Fluke 8508A, Fluke 5522A AC Voltage – Generate, Voltmeters, Generators3 (0.33 to 3.299 99) V (0.33 to 3.299 99) V (100 to 500) kHz 500 kHz to 1 MHz 0.3 % + 2 mV Fluke 8508A, Fluke 5522A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 5 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments DC – AC High Voltage / HV Generators, HV Meters, Pulse Generators (DC & AC to 10kHz) (1 to 7) kV peak (1 to 5) kV rms (1 to 1.6) kV (1.6 to 4) kV (4 to 7) kV 0.77 % 1.1 % 1.3 % Fluke 8508A, Fluke 5522A, Tektronix DPO 7254, Pico Technology TA044 DC Resistance – Generate, Meters, Resistances 10 mΩ to 11 Ω (11 to 32.999) Ω (33 to 329.99) Ω (0.33 to 3.299) kΩ (3.30 to 32.999) kΩ (33 to 329.99) kΩ (0.33 to 3.29) MΩ (3.30 to 32.299) MΩ (33 to 32) MΩ (330 to 1100) MΩ 40 µΩ/Ω + 23 µΩ 30 µΩ/Ω + 24 µΩ 28 µΩ/Ω + 240 µΩ 28 µΩ/Ω + 2.4 mΩ 28 µΩ/Ω + 24 mΩ 29 µΩ/Ω + 180 mΩ 63 µΩ/Ω + 17 Ω 350 µΩ/Ω + 1700 Ω 3000 µΩ/Ω + 170 000 Ω 1.5 % + 560 000 Ω Fluke 8508A Fluke 5522A DC Power – Power Meters & Generators Voltage: (0.33 to 3.2999) V Current: (33 to 329.99) mA (0.33 to 1.0999) A (1.1 to 2.9999) A (3 to 10.9999) A (11 to 20.5) A (0.011 to 1.1) W (0.036 to 3.6) W (0.099 to 9.9) W (0.363 to 36.3) W (0.677 to 67.7) W 0.013 % + 0.093 mW 0.022 % + 0.14 mW 0.043 % + 1.3 mW 0.054 % + 2.1 mW 0.10 % + 2.8 mW Fluke 5522A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 6 of 14 Parameter/Equipment Range CMC2,5 (±) Comments DC Power – Power Meters & Generators Voltage: (3.3 to 32.999) V Current: (33 to 329.99) mA (0.33 to 1.0999) A (1.1 to 2.9999) A (3 to 10.9999) A (11 to 20.5) A (0.109 to 10.9) W (0.363 to 36.3) W (0.99 to 99) W (3.63 to 363) W (6.765 to 676.5) W 0.013 % + 0.93 mW 0.022 % + 1.4 mW 0.043 % + 13 mW 0.054 % + 21 mW 0.10 % + 28 mW Fluke 5522A DC Power – Power Meters & Generators Voltage: (33 to 329.999) V Current: (33 to 329.99) mA (0.33 to 1.0999) A (1.1 to 2.9999) A (3 to 10.9999) A (11 to 20.5) A 1.089 W to 0.11 kW 3.63 W to 0.36 kW 9.9 W to 0.99 kW 36.3 W to 3.63 kW 67.65 W to 6.77 kW 0.013 % + 9.3 mW 0.022 % + 14 mW 0.043 % + 130 mW 0.054 % + 210 mW 0.100 % + 280 mW Fluke 5522A DC Power – Power Meters & Generators Voltage: (33 to 329.999) V Current: (20 to 200) A (200 to 1000) A (0.66 to 66) kW (3.3 to 330) kW 0.006 % + 0.18 W 0.035 % + 1.8 W Fluke 5522A, Fluke 52120A Fluke coil 3 kA
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 7 of 14 Parameter/Equipment Range CMC2,5 (±) Comments DC Power – Power Meters & Generators Voltage: (330 to 1020) V Current: (33 to 329.99) mA (0.33 to 1.0999) A (1.1 to 2.9999) A (3 to 10.9999) A (11 to 20.5) A 3.366 W to 0.34 kW 11.22 W to 1.12 kW 30.6 W to 3.06 kW 112.2 W to 11.22 kW 209.1 W to 20.91 kW 0.013 % + 29 mW 0.022 % + 44 mW 0.043 % + 410 mW 0.054 % + 650 mW 0.100 % + 870 mW Fluke 5522A Parameter/Range Frequency CMC2,5 (±) Comments AC Impedance 10 mΩ to 10 kΩ 10 Hz to 1 kHz 0.10 % Fluke 8508A, Fluke 5522A, Fluke 52120A AC Power – Power Meters & Generators (33 to 329.99) V (33 to 329.99) mA (PF = 1) (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.049 % + 12 mW 0.10 % + 19 mW 0.20 % + 35 mW 0.40 % + 68 mW Fluke 8508A Fluke 5522A AC Power – Power Meters & Generators (33 to 329.99) V (0.33 to 1,0999) A (PF = 1) (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.07 % + 0.077 W 0.60 % + 0.330 W 2.5 % + 1.7 W Fluke 8508A Fluke 5522A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 8 of 14 Parameter/Range Frequency CMC2,5 (±) Comments AC Power – Power Meters & Generators (33 to 329.99) V (1.1 to 2.9999) A (PF = 1) (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.08 % + 0.100 W 0.60 % + 0.340 W 2.5 % + 1.650 W Fluke 8508A Fluke 5522A AC Power – Power Meters & Generators (33 to 329.99) V (3 to 10.999) A (PF = 1) (45 to 100) Hz (100 to 1000) kHz (1 to 5) kHz 0.09 % + 0.97 W 0.12 % + 0.97 W 3.0 % + 0.97 W Fluke 8508A Fluke 5522A AC Power – Power Meters & Generators (33 to 329.99) V (11 to 20.5) A (PF = 1) (45 to 100) Hz (100 to 1000) kHz (1 to 5) kHz 0.14 % + 1.8 W 0.17 % + 1.8 W 3.0 % + 1.8 W Fluke 8508A Fluke 5522A AC Power – Power Meters & Generators (33 to 329.99) V (20 to 100) A (PF = 1) (45 to 1000) Hz (1000 to 3000) Hz 0.14 % + 5.1 W 0.52 % + 5.1 W Fluke 8508A Fluke 5522A Fluke 52120A AC Power – Power Meters & Generators (33 to 329.99) V (100 to 600) A (PF = 1) (45 to 300) Hz (300 to 1000) Hz 0.22 % + 15 W 0.59 % + 15 W Fluke 8508A Fluke 5522A Fluke 52120A Fluke 3kA
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 9 of 14 Parameter/Range Frequency CMC2,5 (±) Comments AC Power – Power Meters & Generators (33 to 329.99) V (600 to 3000) A (PF = 1) (45 to 300) Hz (300 to 1000) Hz 0.43 % + 70 W 0.78 % + 70 W Fluke 8508A Fluke 5522A Fluke 52120A Fluke 3kA Parameter/Frequency Range CMC2,5 (±) Comments Flicker Analyzer (45 to 65) Hz (50 to 300) V 1.2 % Fluke 5522A Temperature simulation for Type J, K, T Thermocouples (-100 to 1200) °C 0.28 °C Fluke 5522A III. Electrical – RF/Microwave Parameter/Equipment Range CMC2,5 (±) Comments Pulse Level / FTB Generators 50 Ω Attenuator 1000 Ω Attenuator (0.5 to 6) kV 5.3 % 8 % Tektronix DPO 7254, Emtest KW 50 & KW1000 Rise Time / FTB Generators (3.5 to 6.5) ns 6.2 % Tektronix DPO 7254, Emtest KW 50 & KW1000 Duration / FTB Generators (35 to 65) ns 8.6 % Tektronix DPO 7254, Emtest KW 50 & KW1000
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 10 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Pulse Level / Surge Generators (0.5 to 6) kV 5.2 % Tektronix DPO 7254, Pico Technology TA044, Kirkby 85054B, Pearson 411, Attenuator 20 dB Rise Time / Surge Generators (0.84 to 1.56) µs 13 % Tektronix DPO 7254, Pico Technology TA044, Kirkby 85054B, Pearson 411, Attenuator 20 dB Duration/ Surge Generators (40 to 60) µs 1.5 % Tektronix DPO 7254, Pico Technology TA044, Kirkby 85054B, Pearson 411, Attenuator 20 dB Reflection Coefficient / Attenuators, LISN, CDN, RF Cables, RF Loads, RF Amplifiers 5 kHz to 100 MHz 100 MHz to 2 GHz (2 to 3) GHz 50 MHz to 2 GHz (2 to 8) GHz (8 to 20.5) GHz 0.012 dB 0.020 dB 0.033 dB 0.053 dB 0.13 dB 0.29 dB Rohde&Schwarz ZCAN, Hewlett-Packard 85052A Transmission /Attenuators, LISN, CDN, RF Cables, RF Amplifiers 10 kHz to 300 MHz 50 MHz to 2 GHz 0.20 dB 0.15 dB Rohde&Schwarz ZCAN, Hewlett- Packard 85052A Voltage Harmonics Analyzer, Voltage THD Analyzer 3 (Max 16 harmonics selected from 2 to 50) 120/230 V. 50/60 Hz fundamental 0.55 % Fluke 8508A, Fluke 5522A, Fluke 52120A
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 11 of 14 Parameter/Equipment Range CMC2,5 (±) Comments Current Harmonics Analyzer, Current THD Analyzer3 (Max 16 harmonics selected from 2 to 50) 10 A at 50 Hz & 17 A at 60 Hz 0.35 % Fluke 8508A, Fluke 5522A, Fluke 52120A IV. Fluid Quantities Parameter/Equipment Range CMC2,5 (±) Comments Liquid Flow / Flowmeters, IP Up to 120 l/min 0.30 % Sinergica Soluzione WSF1MK1,WM1VK5, WM1VK10 & WM1VK20, Sartorius HC1toLC34, RS Components Quantum V. Mechanical Parameter/Equipment Range CMC2 (±) Comments Mass – Weight Scales & Masses (1 to 9.9999) g (10 to 99.999) g (100 to 999.99) g (1 to 4.9999) kg (5 to 9.9999) kg (10 to 49.999) kg (50 to 99.999) kg (100 to 299.99) kg 6.0 mg 8.0 mg 55 mg 0.26 g 0.52 g 2.6 g 5.2 g 16 g Sinergica Soluzione WSF1MK1, WM1VK5, WM1VK10 & WM1VK20
to 50
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 12 of 14 VI. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Humidity – Hygrometers (0 to 60) °C (20 to 95) %RH 1.5 % RH Agilent 34970A + PT100, Delta Ohm HD 2301.OR Humidity – Climatic Chambers Up to 75% RH (> 75 to 95) % RH 2.1 % RH 2.8 % RH Delta Ohm HD 2301.OR Temperature/ Digital Thermometers & Temperature probes (-40 to 140) °C (140 to 200) °C 0.11 °C 0.38 °C Fluke 8508A, Tersid PT100, calibration furnace Temperature – Temperature Chambers (-60 to 180) °C 0.22 °C Agilent 34970A & 34901A, plus PRT thermometer VII. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Frequency Meters 10 Hz to 1 MHz 29 x 10-7 Hz Fluke 5522A, Rohde & Schwarz ESCS30 Frequency Generators3 10 kHz to 2.7 GHz 9.2 x 10-5 Hz Fluke 5522A, Rohde & Schwarz ESCS30 Time / Stopwatches (0 to 3600) sec 20 x 10-6 Hz on 1 hour integration RS Components Quantum, Tektronix DPO 7254, Pico Technology TA044
13--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 13 of 14 Parameter/Equipment Range CMC2 (±) Comments Normalised Site Attenuation of Semianechoic Chamber (SAC) 3 30 MHz to 1 GHz 2.3 dB Antenna BiLog Schwarzbeck VULB 9168, Antenna LogPeriodic Rohde & Schwarz HL223, Antenna Biconica ETS Lindgren 3104C, Antenna Biconica Rohde & Schwarz HK116 E, Rohde & Schwarz SMB100B, HP 83640A, Rohde & Schwarz ESW 44 sVSWR of SAC3 (1 to 18) GHz 3.8 dB Seibersdorf POD16, Seibersdorf POD 618, Rohde & Schwarz SMB100B, HP 83640A, Rohde & Schwarz ESW 44 Field Uniformity3 26 MHz to 6 GHz 4.9 dB Lumiloop Ls Probe 1.2, Rohde & Schwarz SMB100A/B, RF Amplifier, ETS Lindgren 3119, Schwarzbeck STLP 9128, Schwarzbeck BBFA 9146 + coil ____________________________________________ 1 This laboratory offers commercial dimensional testing, calibration and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
30 to 1 MHz to GHz
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7467.01) 02/19/2026 Page 14 of 14 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 In the statement of CMC, % is defined as the percentage of reading unless otherwise indicated.
15ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.