United States

PJF Metrology South

915 Berry Shoals Road, 29334, Duncan, SC, United States

Visit website
A2LA 1856.05ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 1856.05 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1856.05) 2/21/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 PJF METROLOGY SOUTH LLC 915 Berry Shoals Road Duncan, SC 29334 Joshua Bielecki Phone: 616 866 8296 MECHANICAL Valid To: November 30, 2026 Certificate Number: 1856.05 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following tests listed below1, 7: I. Dimensional Testing Parameter/Equipment Range CMC2, 5 (±) Comments Part Measurement3,6 – 3D Volumetric 1D Linear (120 x 48 x 64) in Up to 13 ft Up to 11 ft (Spherical Range) Up to 2 in (2 to 4) in Up to 6 in Up to 12 in [1200 + (43 + M)L] µin 2(2100+ 8L) µin 2(3200 + 11L) µin 220 µin 340 µin 1200 µin 1600 µin CMM Creaform HandySCAN Black Elite Absolute Faro Micrometer Caliper
to 13 ft
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1856.05) 2/21/2025 Page 2 of 2 II. Dimensional Testing/Calibration Parameter/Equipment Range CMC2, 5 (±) Comments Inspection Fixtures and Fixture Gages3,4 – 3D Volumetric 1D Linear (120 x 48 x 64) in Up to 13 ft Up to 11 ft (Spherical Range) Up to 2 in (2 to 4) in Up to 6 in Up to 12 in [1200 + (43 + M)L] µin 2(2100 + 8L) µin 2(3200 + 11L) µin 220 µin 340 µin 1200 µin 1600 µin CMM Creaform HandySCAN Black Elite Absolute Faro Micrometer Caliper ___________________ 1 This laboratory offers commercial dimensional testing/calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measu rement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects suc h as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional calibrations listed above. Accredited test reports issued containing appropriate statements of measurement results, measurement uncertainty, and traceability are considered equivalent to a “calibration” certificate. 5 In the statement of CMC, L = length in inches, M = 3 (Steel), M = 6 (Aluminum), and M = 12.5 (Poly-board). 6 This test is not equivalent to that of a calibration. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
to 13 ft
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations and tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited PJF METROLOGY SOUTH LLC. Duncan, SC for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 21st day of February 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1856.05 Valid to November, 30 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

915 Berry Shoals Road, Duncan, SC, 29334, US

34.93790, -82.14511

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.