- A2LARefreshed
- 4364.01Active
Accredited standards
We have not yet extracted the standard numbers from this lab’s scope document. The scope text we hold is below.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active4364.01
The scope document we hold says it is valid until 2028-02-29.
Accredited scope, certificate 4364.01
This scope has not been split into individual lines yet. Below is the text of the scope document as published.
Part 1 of 5
(A2LA Cert. No. 4364.01) 03/13/2026 Page 1 of 4 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 DC SCIENTIFIC, INC. 6750 McLean Way, Suite D Glen Burnie, MD 21060 Frank Russo Phone: 410 863 1700 CALIBRATION Valid To: February 29, 2028 Certificate Number: 4364.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), ), accreditation is granted to this laboratory at the location listed above as well as the satellite laboratory location listed below to perform the following calibrations 1: I. Fluid Quantities Parameter/Equipment Range CMC2, 4 (±) Comments5 Viscosity Working Viscometers Direct Flow – Suspended Level (Transparent Liquids) <10 mm 2/s (10 to 100) mm2/s (100 to 1000) mm2/s (1000 to 10 000) mm2/s (10 000 to 100 000) mm2/s 0.25 % 0.31 % 0.34 % 0.42 % 0.46 % ASTM D446 ISO 3104 Viscosity Working Viscometers Reverse Flow (Transparent and Opaque) Liquids <10 mm 2/s (10 to 100) mm2/s (100 to 1000) mm2/s (1000 to 10 000) mm2/s (10 000 to 100 000) mm2/s 0.15 % 0.26 % 0.30 % 0.39 % 0.45 % ASTM D446 ISO 3104 Viscosity Working Viscometers Modified Ostwald <10 mm 2/s (10 to 100) mm2/s (100 to 1000) mm2/s (1000 to 10 000) mm2/s (10 000 to 100 000) mm2/s 0.17 % 0.24 % 0.29 % 0.37 % 0.43 % ASTM D446 ISO 3104
Part 2 of 5
(A2LA Cert. No. 4364.01) 03/13/2026 Page 2 of 4 II. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Petroleum Product Analyzer Calibrations for: Dry Vapor Pressure Equivalent (DVPE) 3 Vapor-Liquid Ratio Temperature Determination (VLR) 3 Vapor Pressure of Crude Oil (VPCR x)3 Distillation at Atmospheric Pressure 3 Flash Point by Pensky- Martens Closed Cup 3 Color by Automatic Tristimulus Method 3 Distillation at Reduced Pressure3 Smoke Point of Aviation Turbine Fuel (Automatic Method) 3 Thermal Oxidation Stability of Aviation Turbine Fuels 3 Color of Liquids Using Tristimulus Colorimetry 3 Vapor Pressure (Triple Expansion Method) 3 Micro Distillation 3 (1.0 to 18.6) psi (36 to 80) °C (97 to 176) °F (25 to 180) kPa at 37.8 °C (0 to 400) °C (40 to 370) °C Saybolt D156 (-16 to +30) ASTM D1500 (0 to 8) (0 to 400) °C (0 to 50) mmHg Up to 55 mm (0 to 400) °C (0 to 1200) nm Pt-Co D1209 (0 to 100) (1.0 to 21.0) psi (20 to 400) °C 1.0 % 1.1 % 1.0 % 0.66 % 1.1 % 0.8 % 1.9 % 0.8 % 0.8 % 1.4 % 1.3 % 1.3 % ASTM D5191 ASTM D5188 ASTM D6377 ASTM D86 ASTM D93 ASTM D6045 ASTM D1160 ASTM D1322 ASTM D3241 ASTM D5386 ASTM D6378 ASTM D7345
Part 3 of 5
(A2LA Cert. No. 4364.01) 03/13/2026 Page 3 of 4 SATELLITE LABORATORY DC SCIENTIFIC, INC. 3520 South Sam Houston Parkway East, Suite 400 Houston, TX 77047 Frank Russo Phone: 410 863 1700 II. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Petroleum Product Analyzer Calibrations for: Dry Vapor Pressure Equivalent (DVPE) 3 Vapor-Liquid Ratio Temperature Determination (VLR) 3 Vapor Pressure of Crude Oil (VPCR x)3 Distillation at Atmospheric Pressure 3 Flash Point by Pensky- Martens Closed Cup 3 Color by Automatic Tristimulus Method 3 Distillation at Reduced Pressure3 Smoke Point of Aviation Turbine Fuel (Automatic Method) 3 Thermal Oxidation Stability of Aviation Turbine Fuels 3 Color of Liquids Using Tristimulus Colorimetry 3 Vapor Pressure (Triple Expansion Method) 3 Micro Distillation 3 (1.0 to 18.6) psi (36 to 80) °C (97 to 176) °F (25 to 180) kPa at 37.8 °C (0 to 400) °C (40 to 370) °C Saybolt D156 (-16 to +30) ASTM D1500 (0 to 8) (0 to 400) °C (0 to 50) mmHg Up to 55 mm (0 to 400) °C (0 to 1200) nm Pt-Co D1209 (0 to 100) (2.0 to 21.0) psi (20 to 400) °C 1.0 % 1.1 % 1.0 % 0.66 % 1.1 % 0.8 % 1.9 % 0.8 % 0.8 % 1.4 % 1.3 % 1.3 % ASTM D5191 ASTM D5188 ASTM D6377 ASTM D86 ASTM D93 ASTM D6045 ASTM D1160 ASTM D1322 ASTM D3241 ASTM D5386 ASTM D6378 ASTM D7345 _______________________________
Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.
Other Locations
2 other sites in this organization
Accreditation data refreshed from the A2LA register on .