United States

DC Scientific

6750 McLean Way, Suite D, 21060, Glen Burnie, MD, United States

Visit website
A2LA 4364.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
15
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 15 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM14
ASTM D86
ASTM D93Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
ASTM D446
ASTM D1160
ASTM D1322
ASTM D2162
ASTM D3241
ASTM D5188
ASTM D5191
ASTM D5386
ASTM D6045
ASTM D6377
ASTM D6378
ASTM D7345
Other standards1
ISO 3104Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

4364.01

The scope document we hold says it is valid until 2028-02-29.

View scope

Accredited scope, certificate 4364.01

LineMethodMatrixRange
1ASTM D446; ISO 3104Transparent Liquids; Opaque Liquids-
2ASTM D5191; ASTM D5188; ASTM D6377; ASTM D86; ASTM D93; ASTM D6045; ASTM D1160; ASTM D1322; ASTM D3241; ASTM D5386; ASTM D6378; ASTM D7345Petroleum Product-
3ASTM D5191; ASTM D5188; ASTM D6377; ASTM D86; ASTM D93; ASTM D6045; ASTM D1160; ASTM D1322; ASTM D3241; ASTM D5386; ASTM D6378; ASTM D7345Petroleum Product; Crude Oil; Aviation Turbine Fuel; Liquids-
4ASTM D446; ISO 3104; ASTM D2162Viscometers-
5ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

6750 McLean Way, Suite D, Glen Burnie, MD, 21060, US

39.15954, -76.61515

Open in Maps

Labs with overlapping accredited scope in United States

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.