Spirent Communications US Calibration Center
101 Crawfords Corner Road, Suite 1C05, 07733, Holmdel, NJ, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 3144.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3144.01) Revised 5/21/2026 Page 2 of 3
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Insertion Loss –
(0 to -50) dBm
(0.01 to 3) GHz
(3 to 6) GHz
0.21 dB
0.24 dB
Agilent network analyzer
5071C with calibration kit
85092C (type-N, 50 Ω)
Return Loss –
(0 to -98) dBm
(0.01 to 3) GHz
(3 to 6) GHz
0.041 dB
0.036 dB
Agilent network analyzer
5071C with calibration kit
85092C (type-N, 50 Ω)
VSWR – Measure,
(0 to 2.0) VSWR
(0 to -5) dBm
(-5 to -30) dBm
10 MHz to 8.5 GHz
0.043 VSWR
0.037 VSWR
Agilent network analyzer
5071C with calibration kit
85092C (type-N, 50 Ω)
EVM (% RMS)
(Error Vector Magnitude)
– Measure
(-10 to -111) dBm
EVM Span ≤ 8 MHz,
between 360 MHz to 6
GHz
0.72 % RMS
Agilent signal analyzer
MXA N9020A-508
(type-N, 50 Ω)
RMS means the value of
the difference between a
collection of measured
symbols & ideal symbols
II. Time & Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Time Base –
Measure
10 MHz
1.4 parts in 109
Hz/Hz
Rubidium oscillator &
Agilent/Keysight
53131A/53220A freq.
counter
_______________________________ | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3144.01) Revised 5/21/2026 Page 3 of 3
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 4 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.