United States

Spirent Communications US Calibration Center

101 Crawfords Corner Road, Suite 1C05, 07733, Holmdel, NJ, United States

Visit website
A2LA 3144.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3144.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3144.01) Revised 5/21/2026 Page 2 of 3 Parameter/Range Frequency CMC2, 4 (±) Comments Insertion Loss – (0 to -50) dBm (0.01 to 3) GHz (3 to 6) GHz 0.21 dB 0.24 dB Agilent network analyzer 5071C with calibration kit 85092C (type-N, 50 Ω) Return Loss – (0 to -98) dBm (0.01 to 3) GHz (3 to 6) GHz 0.041 dB 0.036 dB Agilent network analyzer 5071C with calibration kit 85092C (type-N, 50 Ω) VSWR – Measure, (0 to 2.0) VSWR (0 to -5) dBm (-5 to -30) dBm 10 MHz to 8.5 GHz 0.043 VSWR 0.037 VSWR Agilent network analyzer 5071C with calibration kit 85092C (type-N, 50 Ω) EVM (% RMS) (Error Vector Magnitude) – Measure (-10 to -111) dBm EVM Span ≤ 8 MHz, between 360 MHz to 6 GHz 0.72 % RMS Agilent signal analyzer MXA N9020A-508 (type-N, 50 Ω) RMS means the value of the difference between a collection of measured symbols & ideal symbols II. Time & Frequency Parameter/Equipment Range CMC2, 4 (±) Comments Time Base – Measure 10 MHz 1.4 parts in 109 Hz/Hz Rubidium oscillator & Agilent/Keysight 53131A/53220A freq. counter _______________________________
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3144.01) Revised 5/21/2026 Page 3 of 3 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
4ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

101 Crawfords Corner Road, Suite 1C05, Holmdel, NJ, 07733, US

40.34511, -74.18403

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.