Registers refreshed 2026-11-08.See refresh dates
United States

Howell Laboratories Inc.

188 Harrison Road, 04009, Bridgton, ME, United States

Visit website
A2LA 4823.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 2 scope lines.

A2LA certificate 4823.02 · 2 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4823.02) Revised 01/08/2026 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 HOWELL LABORATORIES INC. 188 Harrison Road Bridgton, ME 04009 Chris Steckino Phone: 207 647 3327 csteckino@howelllabs.com CALIBRATION Valid To: November 30, 2026 Certificate Number: 4823.02 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 3: I. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Humidity – Dew Point Sensors -100 °C4 -90 °C -80 °C (-60 to 20) °C 1.2 °C 1.2 °C 0.74 °C 0.40 °C Chilled mirror dew point meter __________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 This temperature is not directly traceable; it is considered consensus traceability.
2ISO/IEC 17025:20 17; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

188 Harrison Road, Bridgton, ME, 04009, US

44.05438, -70.70887

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.