What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 10 scope lines.

A2LA certificate 2734.04 · 10 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.04) 02/05/2026 Page 1 of 9 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 EDDYFI EUROPE SAS 21 avenue du Quebec, 91140 Villebon Sur Yvette, FRANCE Vincent Chassard Phone: +33 160 923 965 CALIBRATION Valid To: February 29, 2028 Certificate Number: 2734.04 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 8: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 6 (±) Comments AC Resistance – Measure 3 Up to 10 Ω 0.45 Ω Agilent 33250A, 33610, Tektronix MDO3032, MDO32 Parameter/Equipment Frequency CMC2, 6 (±) Comments AC Voltage – Measure3 Fixed Points 100 mVrms 10 Hz to 20 kHz 0.12 % + 35 µV Agilent 34401A, 34410A, 34465A
to 10 Ω
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.04) 02/05/2026 Page 2 of 9 II. Magnetic (Eddy Current Instrumentation – MIZ-8xiD Series & MIZ-200iD) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver Amplifier Linearity – Eddy Current Instrumentation 3 (0 to 100) % of Full Scale 0.51 % Agilent 33250A, 33600A Receiver Quadrature – Eddy Current Instrumentation 3 (0 to 360)° 0.024° ZETEC ACM, Agilent 33250A, 33600A Receiver Gain – Eddy Current Instrumentation 3 Up to 80 dB 0.14 % ZETEC ACM, Agilent 33250A, 33600A Parameter/Equipment Frequency CMC2, 4 (±) Comments Coil Driver Frequency – Eddy Current Instrumentation 3 10 Hz to 6 MHz 0.12 % ZETEC ACM, Agilent 53131A Receiver Frequency Bandwidth – Eddy Current Instrumentation 3 (8 to 5000) Hz 0.24 % Agilent 33250A, 33600A III. Time & Frequency Parameter/Range Frequency CMC2, 4, 7 (±) Comments Frequency – Measure3 (10 to 100) mVrms 40 Hz to 300 kHz 0.12 % + 250 µHz Agilent 34401A, 34410A, 34465A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.04) 02/05/2026 Page 3 of 9 IV. Time & Frequency (Ultrasound Instrumentation – Dynaray Series) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response: Low Cutoff High Cutoff Bandwidth Center Linearity of Time Delays Gain Linearity Channel Gain Variation Linearity of Vertical Display Equivalent Input Noise (0.225 to 20) MHz Up to 50 µs (0 to 80) dB <1.5 dB (Zetec) (0 to 28) dB rel. <80 nV/√Hz None, HP1M, HP2M, HP5M, HP10M, LP2M <2.2 % , All others <0.90 % None, BP1-5M, HP1M, LP2M, LP5M, LP10M, LP15M <6.5 % , All others <1.9 % None, HP1M, HP2M, HP10M, LP2M, LP15M <2.5 % , All others <1.0 % None, <3.6 % , All others <1.8 % 0.0063 % 0.47 dB 0.65 dB 0.53 % 7.0 nV/√Hz Agilent 33250A, 33600A, Tektronix MDO32, ZETEC attenuator 10040260, ZETEC ABUXE127A Transmitter – Ultrasound Instrumentation 3 Voltage Rise Time Duration Linearity of Time Delays (25 to 250) V Up to 50 ns (25 to 1000) ns Up to 50 µs 1.8 % 0.78 ns 0.46 ns 0.070 % Agilent 33250A, 33600A, Tektronix MDO32, ZETEC ABUXE127A, 50 ohms/10W load
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.04) 02/05/2026 Page 4 of 9 V. Time & Frequency (Ultrasound Instrumentation – Zircon-15, Zircon-18, Topaz16, Topaz32, Quartz) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response – Zircon-15, Zircon-18, Topaz32, Quartz: Phased Array Low Cutoff High Cutoff Bandwidth Center Conventional Low Cutoff High Cutoff Bandwidth Center Zircon-15 (0.50 to 15) MHz Zircon-18, Topaz32, Quartz (0.50 to 18) MHz <0.70 % HP1M ≤3.2 % None, LP5M, LP10M, HP2M ≤2.4 % , all others ≤1.5 % <0.80 % <0.90 % <0.70 % HP1M ≤8.0 % , None, HP2M ≤5.2 % LP5M, LP10M, BP1-5M, BP2-10M ≤1.9 % All others ≤0.90 % <0.90 % LP5M, HP1M ≤1.3 % All others ≤1.0 % Agilent 33250A &33600A, Tektronix MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF) ZETEC 10059869 (IPEX)
0.5 to 18 MHz
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.04) 02/05/2026 Page 5 of 9 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Frequency Response – Topaz16: Phased Array Low Cutoff High Cutoff Bandwidth Center Conventional Low Cutoff High Cutoff Bandwidth Center Linearity of Time Delays Gain Linearity – Phased Array Conventional (0.50 to 18) MHz Up to 20 µs (0 to 70) dB (0 to 70) dB <0.80 % None, LP2M, LP5M, LP10M, HP1M, HP2M <2.3 % , All others <1.4 % LP2M <1.1 % , All others <0.90 % None, LP2M, LP5M <1.4 % , All others <1.0 % <1.0 % None, HP1M, HP2M <6.5 % LP2M, LP5M, LP10M, HP5M, BP1-5M, BP5-18M <3.0 % , All others <1.7 % LP2M, BP5-18M, BP10-18M <1.6 % , All others <1.0 % None, LP2M, BP5-18M <1.9 % , All others <1.0 % 0.014 % 0.29 dB 0.27 dB Agilent 33250A & 33600A, Tektronix MDO32, ZETEC attenuator 10040260, ZETEC 10040371(ZIF), ZETEC 10059869 (IPEX)
0.5 to 18 MHz
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.04) 02/05/2026 Page 6 of 9 Parameter/Equipment Range5 CMC2, 4, 5 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Channel Gain Variation – Phased Array Conventional Linearity of Vertical Display Equivalent Input Noise <1.5 dB (Zetec) <1.5 dB (Zetec) 28 dB rel. <80 nV/√Hz 0.40 dB 0.38 dB 0.36 % 3.3 nV/√Hz Agilent 33250A & 33600A, Tektronix MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF), ZETEC 10059869 (IPEX) Transmitter – Ultrasound Instrumentation3 Voltage – Phased Array Conventional Rise Time – Phased Array Conventional Duration – Phased Array Conventional Linearity of Time Delays (35 to 75) V (50 to 200) V Up to 50 ns Up to 50 ns (25 to 500) ns (25 to 500) ns Up to 20 µs 2.0 % 2.6 % 0.57 ns 0.34 ns 0.51 ns 0.48 ns 0.051 % Agilent 33250A & 33600A, Tektronix MDO32, ZETEC 10040371 (ZIF), ZETEC 10059869 (IPEX)
to 1.5 dB
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.04) 02/05/2026 Page 7 of 9 VI. Time & Frequency (Ultrasound Instrumentation – Topaz64, Emerald64) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response: Phased Array Low Cutoff High Cutoff Bandwidth Center Conventional Low Cutoff High Cutoff Bandwidth Center (0.50 to 18) MHz HP0.6M, LP2M, LP5M, LP10M, HP1M, BP1-5M: <±6.5 % HP2M, BP1.8-7M, BP2-10M: <±3.4 % All others: <±1.7 % HP0.6M, LP2M, LP5M, LP10M, BP1-5M: <±2.5 % All others: <±1.1 % HP0.6M, LP2M, LP5M, BP1- 5M, BP5-10M: <±3.6 % All others: <±1.9 % HP0.6M, LP2M, LP5M, LP10M, BP1-5M, BP1.8-7M: < ±4.3 % All others: <±1.9 % LP2M, BP1-4M, BP1.1-4.5M, BP1.9-7.5M, BP5-20M, BP0.55- 6M: <±4.2 % All others: <±3.0 % LP2M, BP1-4M, HP3M: <±2.1 % All others: <±1.2 % LP2M, BP1-4M, BP2-8M, BP5- 20M, HP10M: <±3.1 % All others: <±2.0 % LP2M, BP1-4M, BP1.1-4.5M, BP2-8M, HP10M, HP3M, BP0.55-6M: <±3.7 % All others: <±2.0 % Agilent 33250A, 33600A, Tektronix MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF) ZETEC 10059869 (IPEX)
0.5 to 18 MHz
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.04) 02/05/2026 Page 8 of 9 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Linearity of Time Delays Gain Linearity – Phased Array Conventional Channel Gain Variation – Phased Array Conventional Linearity of Vertical Display Equivalent Input Noise Phased Array Conventional Up to 20 µs (0 to 70) dB (0 to 70) dB <1.5 dB (Zetec) <1.5 dB (Zetec) 28 dB rel. <80 nV/√Hz 0.088 % 0.29 dB 0.27 dB 0.41 dB 0.37 dB 1.2 % 9.0 nV/√Hz 28 nV/√Hz Agilent 33250A, Tektronix MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF) ZETEC 10059869 (IPEX) Transmitter – Ultrasound Instrumentation3 Voltage – Phased Array Conventional Rise Time – Phased Array Conventional Duration – Phased Array Conventional Linearity of Time Delays (10 to 75) V (20 to 200) V Up to 50 ns Up to 50 ns (25 to 500) ns (25 to 500) ns Up to 20 µs 2.2 % 2.7 % 0.57 ns 0.34 ns 0.49 ns 0.57 ns 0.056 % Agilent 33250A, Tektronix MDO3032, MDO32, ZETEC 10040371 (ZIF) ZETEC 10059869 (IPEX) 50 ohms/10W load __________________________________________
to 20 µs
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.04) 02/05/2026 Page 9 of 9 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages represent percent of reading unless otherwise noted. 5 References to decibels (dB) refer to dB in voltage. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
10ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

21 avenue du Quebec, Villebon Sur Yvette, 91140, France, Villebon Sur Yvette, FR

48.70000, 2.22765

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.