Eddyfi Europe
21 avenue du Quebec, Villebon Sur Yvette, 91140, France, Villebon Sur Yvette, France
Visit website- Scope lines
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 10 scope lines.
A2LA certificate 2734.04 · 10 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2734.04) 02/05/2026 Page 1 of 9
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
EDDYFI EUROPE SAS
21 avenue du Quebec,
91140 Villebon Sur Yvette, FRANCE
Vincent Chassard Phone: +33 160 923 965
CALIBRATION
Valid To: February 29, 2028 Certificate Number: 2734.04
In recognition of the successful completion of the A2LA evaluation process, (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 8:
I. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
AC Resistance –
Measure
3
Up to 10 Ω
0.45 Ω
Agilent 33250A,
33610, Tektronix
MDO3032, MDO32
Parameter/Equipment
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Measure3
Fixed Points
100 mVrms
10 Hz to 20 kHz
0.12 % + 35 µV
Agilent 34401A,
34410A, 34465A | to 10 Ω |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2734.04) 02/05/2026 Page 2 of 9
II. Magnetic (Eddy Current Instrumentation – MIZ-8xiD Series & MIZ-200iD)
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Receiver Amplifier
Linearity – Eddy Current
Instrumentation
3
(0 to 100) % of Full
Scale
0.51 %
Agilent 33250A, 33600A
Receiver Quadrature –
Eddy Current
Instrumentation
3
(0 to 360)°
0.024°
ZETEC ACM, Agilent
33250A, 33600A
Receiver Gain – Eddy
Current Instrumentation
3
Up to 80 dB
0.14 %
ZETEC ACM, Agilent
33250A, 33600A
Parameter/Equipment
Frequency
CMC2, 4 (±)
Comments
Coil Driver Frequency –
Eddy Current
Instrumentation
3
10 Hz to 6 MHz
0.12 %
ZETEC ACM, Agilent
53131A
Receiver Frequency
Bandwidth – Eddy Current
Instrumentation
3
(8 to 5000) Hz
0.24 %
Agilent 33250A, 33600A
III. Time & Frequency
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
Frequency – Measure3
(10 to 100) mVrms
40 Hz to 300 kHz
0.12 % + 250 µHz
Agilent 34401A, 34410A,
34465A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2734.04) 02/05/2026 Page 3 of 9
IV. Time & Frequency (Ultrasound Instrumentation – Dynaray Series)
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Receiver – Ultrasound
Instrumentation3
Frequency Response:
Low Cutoff
High Cutoff
Bandwidth
Center
Linearity of Time
Delays
Gain Linearity
Channel Gain
Variation
Linearity of Vertical
Display
Equivalent Input Noise
(0.225 to 20) MHz
Up to 50 µs
(0 to 80) dB
<1.5 dB (Zetec)
(0 to 28) dB rel.
<80 nV/√Hz
None, HP1M, HP2M, HP5M,
HP10M, LP2M <2.2 % , All
others <0.90 %
None, BP1-5M, HP1M, LP2M,
LP5M, LP10M, LP15M <6.5 % ,
All others <1.9 %
None, HP1M, HP2M, HP10M,
LP2M, LP15M <2.5 % , All
others <1.0 %
None, <3.6 % , All others <1.8 %
0.0063 %
0.47 dB
0.65 dB
0.53 %
7.0 nV/√Hz
Agilent 33250A,
33600A,
Tektronix
MDO32, ZETEC
attenuator
10040260,
ZETEC
ABUXE127A
Transmitter –
Ultrasound
Instrumentation
3
Voltage
Rise Time
Duration
Linearity of Time
Delays
(25 to 250) V
Up to 50 ns
(25 to 1000) ns
Up to 50 µs
1.8 %
0.78 ns
0.46 ns
0.070 %
Agilent 33250A,
33600A,
Tektronix
MDO32, ZETEC
ABUXE127A,
50 ohms/10W
load | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2734.04) 02/05/2026 Page 4 of 9
V. Time & Frequency (Ultrasound Instrumentation – Zircon-15, Zircon-18, Topaz16, Topaz32, Quartz)
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Receiver – Ultrasound
Instrumentation3
Frequency Response –
Zircon-15, Zircon-18,
Topaz32, Quartz:
Phased Array
Low Cutoff
High Cutoff
Bandwidth
Center
Conventional
Low Cutoff
High Cutoff
Bandwidth
Center
Zircon-15
(0.50 to 15) MHz
Zircon-18,
Topaz32, Quartz
(0.50 to 18) MHz
<0.70 %
HP1M ≤3.2 %
None, LP5M, LP10M, HP2M
≤2.4 % , all others ≤1.5 %
<0.80 %
<0.90 %
<0.70 %
HP1M ≤8.0 % ,
None, HP2M ≤5.2 %
LP5M, LP10M, BP1-5M,
BP2-10M ≤1.9 %
All others ≤0.90 %
<0.90 %
LP5M, HP1M ≤1.3 %
All others ≤1.0 %
Agilent 33250A
&33600A,
Tektronix
MDO32,
ZETEC attenuator
10040260,
ZETEC 10040371
(ZIF) ZETEC
10059869 (IPEX) | 0.5 to 18 MHz |
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2734.04) 02/05/2026 Page 5 of 9
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Receiver – Ultrasound
Instrumentation3 (cont)
Frequency Response –
Topaz16:
Phased Array
Low Cutoff
High Cutoff
Bandwidth
Center
Conventional
Low Cutoff
High Cutoff
Bandwidth
Center
Linearity of Time
Delays
Gain Linearity –
Phased Array
Conventional
(0.50 to 18) MHz
Up to 20 µs
(0 to 70) dB
(0 to 70) dB
<0.80 %
None, LP2M, LP5M, LP10M,
HP1M, HP2M <2.3 % ,
All others <1.4 %
LP2M <1.1 % ,
All others <0.90 %
None, LP2M, LP5M <1.4 % ,
All others <1.0 %
<1.0 %
None, HP1M, HP2M <6.5 %
LP2M, LP5M, LP10M, HP5M,
BP1-5M, BP5-18M <3.0 % , All
others <1.7 %
LP2M, BP5-18M, BP10-18M
<1.6 % ,
All others <1.0 %
None, LP2M, BP5-18M <1.9 % ,
All others <1.0 %
0.014 %
0.29 dB
0.27 dB
Agilent 33250A
& 33600A,
Tektronix
MDO32,
ZETEC
attenuator
10040260,
ZETEC
10040371(ZIF),
ZETEC
10059869 (IPEX) | 0.5 to 18 MHz |
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2734.04) 02/05/2026 Page 6 of 9
Parameter/Equipment
Range5
CMC2, 4, 5 (±)
Comments
Receiver – Ultrasound
Instrumentation3 (cont)
Channel Gain Variation –
Phased Array
Conventional
Linearity of Vertical Display
Equivalent Input Noise
<1.5 dB (Zetec)
<1.5 dB (Zetec)
28 dB rel.
<80 nV/√Hz
0.40 dB
0.38 dB
0.36 %
3.3 nV/√Hz
Agilent 33250A &
33600A, Tektronix
MDO32, ZETEC
attenuator 10040260,
ZETEC 10040371 (ZIF),
ZETEC 10059869
(IPEX)
Transmitter – Ultrasound
Instrumentation3
Voltage –
Phased Array
Conventional
Rise Time –
Phased Array
Conventional
Duration –
Phased Array
Conventional
Linearity of Time Delays
(35 to 75) V
(50 to 200) V
Up to 50 ns
Up to 50 ns
(25 to 500) ns
(25 to 500) ns
Up to 20 µs
2.0 %
2.6 %
0.57 ns
0.34 ns
0.51 ns
0.48 ns
0.051 %
Agilent 33250A &
33600A, Tektronix
MDO32, ZETEC
10040371 (ZIF), ZETEC
10059869 (IPEX) | to 1.5 dB |
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2734.04) 02/05/2026 Page 7 of 9
VI. Time & Frequency (Ultrasound Instrumentation – Topaz64, Emerald64)
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Receiver – Ultrasound
Instrumentation3
Frequency Response:
Phased Array
Low Cutoff
High Cutoff
Bandwidth
Center
Conventional
Low Cutoff
High Cutoff
Bandwidth
Center
(0.50 to 18) MHz
HP0.6M, LP2M, LP5M, LP10M,
HP1M, BP1-5M: <±6.5 %
HP2M, BP1.8-7M, BP2-10M:
<±3.4 %
All others: <±1.7 %
HP0.6M, LP2M, LP5M, LP10M,
BP1-5M: <±2.5 %
All others: <±1.1 %
HP0.6M, LP2M, LP5M, BP1-
5M, BP5-10M: <±3.6 %
All others: <±1.9 %
HP0.6M, LP2M, LP5M, LP10M,
BP1-5M, BP1.8-7M: < ±4.3 %
All others: <±1.9 %
LP2M, BP1-4M, BP1.1-4.5M,
BP1.9-7.5M, BP5-20M, BP0.55-
6M: <±4.2 %
All others: <±3.0 %
LP2M, BP1-4M, HP3M:
<±2.1 %
All others: <±1.2 %
LP2M, BP1-4M, BP2-8M, BP5-
20M, HP10M: <±3.1 %
All others: <±2.0 %
LP2M, BP1-4M, BP1.1-4.5M,
BP2-8M, HP10M, HP3M,
BP0.55-6M: <±3.7 %
All others: <±2.0 %
Agilent 33250A,
33600A,
Tektronix
MDO3032,
MDO32,
ZETEC
attenuator
10040260,
ZETEC
10040371 (ZIF)
ZETEC
10059869 (IPEX) | 0.5 to 18 MHz |
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2734.04) 02/05/2026 Page 8 of 9
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Receiver – Ultrasound
Instrumentation3 (cont)
Linearity of Time Delays
Gain Linearity –
Phased Array
Conventional
Channel Gain Variation –
Phased Array
Conventional
Linearity of Vertical Display
Equivalent Input Noise
Phased Array
Conventional
Up to 20 µs
(0 to 70) dB
(0 to 70) dB
<1.5 dB (Zetec)
<1.5 dB (Zetec)
28 dB rel.
<80 nV/√Hz
0.088 %
0.29 dB
0.27 dB
0.41 dB
0.37 dB
1.2 %
9.0 nV/√Hz
28 nV/√Hz
Agilent 33250A,
Tektronix
MDO3032,
MDO32,
ZETEC
attenuator
10040260,
ZETEC
10040371 (ZIF)
ZETEC
10059869 (IPEX)
Transmitter – Ultrasound
Instrumentation3
Voltage –
Phased Array
Conventional
Rise Time –
Phased Array
Conventional
Duration –
Phased Array
Conventional
Linearity of Time Delays
(10 to 75) V
(20 to 200) V
Up to 50 ns
Up to 50 ns
(25 to 500) ns
(25 to 500) ns
Up to 20 µs
2.2 %
2.7 %
0.57 ns
0.34 ns
0.49 ns
0.57 ns
0.056 %
Agilent 33250A,
Tektronix
MDO3032,
MDO32,
ZETEC
10040371 (ZIF)
ZETEC
10059869 (IPEX)
50 ohms/10W
load
__________________________________________ | to 20 µs |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2734.04) 02/05/2026 Page 9 of 9
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, percentages represent percent of reading unless otherwise noted.
5 References to decibels (dB) refer to dB in voltage.
6 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 10 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
21 avenue du Quebec, Villebon Sur Yvette, 91140, France, Villebon Sur Yvette, FR
48.70000, 2.22765
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.