Registers refreshed 2026-11-08.See refresh dates
United States

R. L. Guimont

9071 Technology Drive, 46038, Fishers, IN, United States

Visit website
A2LA 1620.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 1620.01 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1620.01) 05/06/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 R. L. GUIMONT CO., INC. 9071 Technology Drive Fishers, IN 46038 Jon R. Guimont Phone: 317 577 5565 CALIBRATION Valid To: June 30, 2027 Certificate Number: 1620.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Optical Comparators3 – Magnification Linear Deviation 10x to 100x Up to 12 in Up to 300 mm 79 µin (50 + 6.0L) µin Glass magnification scale Glass master Video Measuring Systems3 – Measuring Stage Z-Axis (8 in × 6 in) to (30 in × 24 in) Up to 12 in Up to 10 in (11 + 8.5L) µin (50 + 6.0L) µin (47 + 3.4L) µin Glass grid/Steel length artifact/diameter artifact, non-linear calibration Glass scale, linear calibration Gage blocks 1 This laboratory offers commercial calibration service and field calibration service.
10 to 100 x
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1620.01) 05/06/2025 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

9071 Technology Drive, Fishers, IN, 46038, US

39.95559, -86.01387

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.