United States

Exponent

149 Commonwealth Drive, 94025, Menlo Park, CA, United States

Visit website
A2LA 2561.03ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
15
A2LA certificate
1
Sites in our directory
5
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 15 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM9
ASTM D7334
ASTM E334
ASTM E573
ASTM E1252
ASTM F561Exclusion

Limits written next to it

ASTM F561 ( except section 16)

Exclusion. Written next to it on line 1 of A2LA certificate 2561.03.

ASTM F2129
ASTM F3044
ASTM F3306
ASTM G5
ISO3
ISO 7810Identification cards - Physical characteristics
ISO 12891-2Retrieval and analysis of surgical implants - Part 2: Analysis of retrieved surgical implants
ISO/IEC 10373-1Cards and security devices for personal identification - Test methods - Part 1: General characteristics
Other standards3
EPA 8270Semivolatile Organic Compounds by Gas Chromatography/Mass Spectrometry (GC/MS)
IEC 60825-1
IEC 62471-1

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

2561.03

The scope document we hold says it is valid until 2027-06-30.

View scope

Accredited scope, certificate 2561.03

LineMethodMatrixRange
1ASTM F561; ISO 12891-2; ASTM D7334; ASTM F2129; ASTM G5; ASTM F3044; ASTM F3306; ASTM E334; ASTM E573; ASTM E1252; EPA Method 8270D; IEC 60825-1medical grade plastics, metals and biomaterials, medical consumables, tissue and medical devices400 to 1100 nm
2IEC 62471-1; ISO/IEC 10373-1; ISO/IEC 7810; ANSI 322lamps and lamp systems; medical and non-medical plastics and metals-
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited EXPONENT, INC. Menlo Park, CA for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 4th day of June 2025. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2561.03 Valid to June 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

149 Commonwealth Drive, Menlo Park, CA, 94025, US

37.45197, -122.17799

Open in Maps

Other Locations

4 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.