WesDyne Sweden
Kemistvägen 5, 183 79, Täby, Sweden
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at WesDyne Sweden?
Claim this profile to keep it accurate.
Register record
- SWEDACRefreshed
- A001205-001Active
Accredited standards
5Our reading of the SWEDAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN 3452-1Name not checked yet
SS-EN ISO/IEC 17025:2018; SS-EN 3452-1; SS-EN ISO 23277; SS-EN ISO 17637; SS-EN ISO 10042; SS-EN ISO 5817
ISO 5817Welding - Fusion-welded joints in steel, nickel, titanium and their alloys (beam welding excluded) - Quality levels for imperfections
SS-EN ISO/IEC 17025:2018; SS-EN 3452-1; SS-EN ISO 23277; SS-EN ISO 17637; SS-EN ISO 10042; SS-EN ISO 5817
ISO 10042Welding - Arc-welded joints in aluminium and its alloys - Quality levels for imperfections
SS-EN ISO/IEC 17025:2018; SS-EN 3452-1; SS-EN ISO 23277; SS-EN ISO 17637; SS-EN ISO 10042; SS-EN ISO 5817
ISO 17637Non-destructive testing of welds - Visual testing of fusion-welded joints
SS-EN ISO/IEC 17025:2018; SS-EN 3452-1; SS-EN ISO 23277; SS-EN ISO 17637; SS-EN ISO 10042; SS-EN ISO 5817
ISO 23277Non-destructive testing of welds - Penetrant testing - Acceptance levels
SS-EN ISO/IEC 17025:2018; SS-EN 3452-1; SS-EN ISO 23277; SS-EN ISO 17637; SS-EN ISO 10042; SS-EN ISO 5817
Scope as published by SWEDAC
2 lines
ISO/IEC 17025
ActiveA001205-001
Accredited scope, certificate A001205-001
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | ndt | SS-EN ISO/IEC 17025:2018; SS-EN 3452-1; SS-EN ISO 23277; SS-EN ISO 17637; SS-EN ISO 10042; SS-EN ISO 5817 | Metal | - |
| 2 | - | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Sweden
- WesDyne SwedenTäby · under 1 kmSWEDACShares 1 accredited materialMetal
- Kiwa SwedenSolna · ~10 kmSWEDACShares 1 accredited materialMetal
- Nordic NDTSaltsjö-Boo · ~16 kmSWEDACShares 1 accredited materialMetal
- Kiwa SwedenVästerås · ~87 kmSWEDACShares 1 accredited materialMetal
- KanthalHallstahammar · ~107 kmSWEDACShares 1 accredited materialMetal
Accreditation data refreshed from the SWEDAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the SWEDAC entry linked above.