Registers refreshed 2026-11-20.See refresh dates
France

ESIGELEC

Technopôle du Madrillet Av Galilée, 76800, SAINT-ETIENNE DU ROUVRAY, France

COFRAC 1-6645ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
4
COFRAC certificate
1
Site in our directory
1
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 4 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements

Certificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.

IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments

Read from the scope as published by COFRAC. Register refreshed 2026-11-20.

Scope as published by COFRAC

2 lines
COFRAC

ISO/IEC 17025

Active

1-6645

View scope

Accredited scope, certificate 1-6645

LineMethodMatrixRange
1NF EN ISO/IEC 17025:2017--
2NF EN 55016-2-1; NF EN 61000-6-3; NF EN 61000-6-4; NF EN 55011Electrical equipmentSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Technopôle du Madrillet Av Galilée, SAINT-ETIENNE DU ROUVRAY, 76800, FR

49.38310, 1.09163

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.