X-Rite - Munich, Germany
FraunhoFerster 11b, Martinsried, 82152, Germany, Martinsried, Germany
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2108.05 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.05) 01/15/2026 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO 17025:2017
X-RITE - MUNICH, GERMANY
FraunhoFerster 11b, Martinsried 82152, GERMANY
Kevin Irwin Phone: 616 219 8681
CALIBRATION
Valid To: December 31, 2027 Certificate Number: 2108.05
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 7:
I. Optical Quantities
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
Model 962, 964,
(0/45 Optical
Geometry)
Model CI60, CI61,
CI62, CI64, CI64
UV, CI4xxx
Model CI7xxx
3
Model ERX313
Model ERX1453
(400 to 420) nm
(430 to 700) nm
400 nm
(410 to 700) nm
(360 to 400) nm
(410 to 750) nm
(330 to 390) nm
(400 to 540) nm
(550 to 730) nm
(330 to390) nm
(400 to 540) nm
(550 to 730) nm
1.7 % R
0.92 % R
0.95 % R
0.41 % R
0.83 % R
0.43 % R
1.3 % R
0.55 % R
0.38 % R
1.3 % R
0.53 % R
0.38 % R
White reflection
standards with:
SPP X-it 962
SPP CI6x
SPP CI7x
MUC-WI-001
MUC-WI-002 | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.05) 01/15/2026 Page 2 of 3
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
(cont)
Model ColorXRA 45,
ColorXRA 45F,
ColorXRA 45 Lab,
ColorXRA 45F Lab
3
Model MA-Tx Series
and OEM Variants
(KOH Spectro-
photometer)
(Aspecular Optical
Geometry)
-15 °
15 °
25 °
45 °
75 °
110 °
(330 to 390) nm
(400 to 540) nm
(550 to 730) nm
400 nm
(410 to 700) nm
(400 to 420) nm
(430 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 420) nm
(430 to 700) nm
400 nm
(410 to 700) nm
1.4 % R
0.56 % R
0.46 % R
1.1 % R
1.0 % R
1.1 % R
0.85 % R
0.95 % R
0.80 % R
0.88 % R
0.73 % R
0.98 % R
0.78 % R
0.98 % R
0.92 % R
White reflection
standards with:
MUC-WI-003
White reflection
standards with:
Kohinoor
service manual
Optical Radiation3
(Lightbooth)
2300 K (Horizon)
2856 K (Illuminate A)
20 K
22 K
X-Rite LightSpex
Pro radiometer
___________________________
1 This laboratory offers commercial calibration service and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.05) 01/15/2026 Page 3 of 3
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, R is the reflectance.
5 The product families have the same optical geometries and calibration procedures. The features on the
display and outputs are the only differences.
6 White reflection standards apply to the calibration of approximately 80 % reflectance on a neutral white
ceramic. Color calibration is mainly based on inter-instrument agreement.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.