Registers refreshed 2026-11-20.See refresh dates
Italy

ACQUE DEL CHIAMPO S.P.A. SOCIETA' BENEFIT

Via Ferraretta 20, 36071, Arzignano, Italy

Visit website
ACCREDIA 00548ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
30
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 30 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO13
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 8467Water quality - Determination of permanganate index
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 10523Water quality - Determination of pH
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 15587-2Water quality - Digestion for the determination of selected elements in water - Part 2: Nitric acid digestion
ISO 15923-1Water quality - Determination of selected parameters by discrete analysis systems - Part 1: Ammonium, nitrate, nitrite, chloride, orthophosphate, sulfate and silicate with photometric detection
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
ISO 20236Water quality - Determination of total organic carbon (TOC), dissolved organic carbon (DOC), total bound nitrogen (TNb) and dissolved bound nitrogen (DNb) after high temperature catalytic oxidative combustion
EPA9
EPA 524.3
EPA 536
EPA 3512
EPA 3535
EPA 3550Ultrasonic Extraction
EPA 5030Purge-and-Trap for Aqueous Samples
EPA 7199
EPA 8260Volatile Organic Compounds by Gas Chromatography/Mass Spectrometry
EPA 8327
EN6
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 12457-2Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 2: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with particle size below 4 mm (without or with size reduction)
EN 14346Characterization of waste - Calculation of dry matter by determination of dry residue or water content
EN 16192
EN 17892Water quality - Determination of selected per- and polyfluoroalkyl substances in drinking water - Method using liquid chromatography/tandem-mass spectrometry (LC-MS/MS)Some clauses

Limits written next to it

UNI EN 17892:2024 - solo/only Parte

Some clauses. Written next to it on line 4 of ACCREDIA certificate 00548.

EN 27888Water quality - Determination of electrical conductivity
Other standards2
APAT CNR IRSA 2060 Man 29 2003pH
ASTM D7574

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

7 lines
ACCREDIA

ISO/IEC 17025

Active

00548

View scope

Accredited scope, certificate 00548

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; ASTM D7574-23; APAT CNR IRSA 2060 Man 29 2003; EPA 3512 2021; EPA 8327 2021; APAT CNR IRSA 2030 Man 29 2003; EPA 3535A 2007Waste waterSee scope document
2UNI CEI EN ISO/IEC 17025:2018; EPA 3512 2021; EPA 8327 2021--
3EPA 524.3 2009; Rapporti ISTISAN 2011/18 pag 65; Rapporti ISTISAN 2007/31 pag 195; UNI EN ISO 10304-4:2022; UNI EN ISO 9308-1:2017; UNI EN ISO 9308-2:2014; UNI EN 1484:1999; Rapporti ISTISAN 2007/31 pag 31; UNI EN ISO 14189:2016-0.15 to µg/L
4UNI CEI EN ISO/IEC 17025:2018; UNI EN 17892:2024--
5UNI CEI EN ISO/IEC 17025:2018; AFNOR BRD 07/15-12/07; UNI EN ISO 6222:2001; EPA 536 2007; UNI EN ISO 16266:2008; APAT CNR IRSA 3020 Man 29 2003; UNI EN ISO 7027-1:2016; UNI EN ISO 8467:1997; EPA 7199 1996; ISO 15923-1:2013; ISO 17294-2:2023; APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 7010 C Man 29 2003; APAT CNR IRSA 7040 C Man 29 2003; APAT CNR IRSA 7030 F Man 29 2003; APAT CNR IRSA 7080 Man 29 2003; APAT CNR IRSA 2090 B Man 29 20Drinking water0.02 to ug/L
6UNI CEI EN ISO/IEC 17025:2018; EPA 5030C 2003; EPA 8260D 2018; APAT CNR IRSA 5070 A1 Man 29 2003; ISPRA Man 117 2014; APAT CNR IRSA 3010 B + 3020 Man 29 2003; APAT CNR IRSA 3010 A + 3020 Man 29 2003; UNI EN ISO 20236:2025; APAT CNR IRSA 5010 B1 Man 29 2003; EPA 3512 2021; EPA 3535A 2007; EPA 8327 2021; APAT CNR IRSA 4020 Man 29 2003Waste waterSee scope document
7EPA 3550C 2007; EPA 8327 2021; CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008; CNR IRSA 1 Q 64 Vol 2 1984; UNI EN 12457-2:2004; UNI EN 16192:2012; UNI EN ISO 15587-2:2002 Annex A; ISO 17294-2:2023; UNI EN 12457-2:2004; UNI EN 16192:2012; UNI EN 27888:1995; UNI EN 12457-2:2004; UNI EN 16192:2012; UNI EN ISO 10523:2012; UNI EN 14346:2007 Met ARifiuti/Wastes; Su eluati da test di cessione/In eluates from leaching testSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Ferraretta 20, Arzignano, 36071, IT

45.50847, 11.37222

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.