Registers refreshed 2026-11-08.See refresh dates
Germany

ANECO Institut für Arbeitsschutz GmbH &

Wehnerstraße 1-7, 41068, Mönchengladbach, Germany

Visit website
DAKKS D-PL-19658-01-00ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
1
DAKKS certificate
1
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ISO 16740Workplace air - Determination of hexavalent chromium in airborne particulate matter - Method by ion chromatography and spectrophotometric measurement using diphenyl carbazide

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

7 lines
DAKKS

ISO/IEC 17025

Active

D-PL-19658-01-00

View scope

Accredited scope, certificate D-PL-19658-01-00

LineMethodMatrixRange
1-Aerosolen, Faserstäuben, von anorganischen und organischen Gasen und Dämpfen
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Diese Urkundenanlage gilt nur zusammen mit der schriftlich erteilten Urkunde und gibt den Stand zum Zeitpunkt des Ausstellungsdatums wieder. Der jeweils aktuelle Stand der gültigen und überwachten Akkreditierung ist der Datenbank akkreditierter Stellen der Deutschen Akkreditierungsstelle zu entnehmen (www.dakks.de) Verwendete Abkürzungen: siehe letzte Seite Seite 1 von 7 Deutsche Akkreditierungsstelle Anlage zur Akkreditierungsurkunde D-PL-19658-01-00 nach DIN EN ISO/IEC 17025:2018 Gültig ab: 07.03.2025 Ausstellungsdatum: 07.03.2025 Inhaber der Akkreditierungsurkunde: ANECO Institut für Arbeitsschutz GmbH & Co. Wehnerstraße 1, 41068 Mönchengladbach mit dem Standort ANECO Institut für Arbeitsschutz GmbH & Co. Wehnerstraße 1, 41068 Mönchengladbach Das Prüflaboratorium erfüllt die Anforderungen gemäß DIN EN ISO/IEC 17025:2018, um die in dieser Anlage aufgeführten Konformitätsbewertungstätigkeiten durchzuführen. Das Prüflaboratorium erfüllt gegebenenfalls zusätzliche gesetzliche und normative Anforderungen, einschließlich solcher in relevanten sektoralen Programmen, sofern diese nachfolgend ausdrücklich bestätigt werden. Die Anforderungen an das Managementsystem in der DIN EN ISO/IEC 17025 sind in einer für Prüflaboratorien relevanten Sprache verfasst und stehen insgesamt in Übereinstimmung mit den Prinzipien der DIN EN ISO 9001. Prüfungen in den Bereichen: Ermittlung von Aerosolen, Faserstäuben, von anorganischen und organischen Gasen und Dämpfen und von ausgewählten Parametern und/oder in ausgewählten Gebieten bei Arbeitsplatzmessungen gemäß Gefahrstoffverordnung §7, Abs. 10
-
2IFA Nr. 6068; IFA Nr. 7284; IFA Nr. 7630; DGUV-I 213-541; IFA Nr. 6015; IFA Nr. 7808; NIOSH-Method No. 7301; DGUV-I 213-503; DGUV-I 213-513; IFA Nr. 6310; DGUV-I 213-554; IFA Nr. 6645; DGUV-I 213-515; IFA Nr. 7755 u. 7757; DGUV-I 213-510; IFA Nr. 8588; IFA Nr. 8600Aerosole (ohne Faserstäube); A-Staub Alveolengängige Fraktion; E-Staub Einatembare Fraktion; Holzstaub Holzstaub; Metalle und Metallverbindungen einschließlich Chrom VI; Metalle (z. B. Arsen, Beryllium, Blei, Cadmium, Chrom, Cobalt, Kupfer, Nickel, Selen, Silber, Zinkoxid)-
3DGUV-I 213-529; ISO 16740; DGUV-I 213-505; DGUV-I 213-546Aerosole (ohne Faserstäube); Antimontrioxid; Chrom (VI)-Verbindungen; Amorphe Kieselsäuren; Kristalline Mineralstäube Quarz; Asbest, Fasern; Anorganische Gase und Dämpfe; Cyanwasserstoff und Cyanide-
4IFA Nr. 6725; IFA Nr. 6172; IFA Nr. 6173; IFA Nr. 7512; IFA Nr. 7638; DFG Luftanalysenband 1--
5OSHA Method No. 32; IFA Nr. 6045; IFA Nr. 6550; NIOSH Method No. 2004; OSHA PV2111; NIOSH Method No. 5506; IFA Nr. 6305 Verfahren Nr. 1; IFA Nr. 8000; DGUV-I 213-547--
6IFA Nr. 8530; IFA Nr. 7750; DFG Luftanalysen-band 1; IFA Nr. 7050; IFA Nr. 7670; DGUV-I 213-523; IFA Nr. 8172Quecksilber (Aerosol und Dampf); Kühlschmierstoffe; Weichmacher Phthalate; Dieselmotoremissionen (DME); Isocyanate Monomere Diisocyanate, Totalkonzentration reaktiver Isocyanatgruppen (TRIG) und Polyisocyanatgehalt; N-Nitrosamine; Pharmawirkstoffe-
7-Luft in Arbeitsbereichen
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-19658-01-00 Gültig ab: 07.03.2025 Ausstellungsdatum: 07.03.2025 Seite 7 von 7 Die aufgeführten Verfahren entsprechen den Anforderungen, die bei der Ermittlung der Konzentration gefährlicher Stoffe an Arbeitsplätzen gelten. Zusammen mit der Prüfung der in ausreichender Anzahl für die einzelnen Gruppen vorgelegten Berichte, wird für die Gruppe 1 Gruppe 2 Gruppe 3 Gruppe 4 Gruppe 5 Systeme mit zweiphasiger Probenahme mit Summenbestimmung: PCDD/F, Kühlschmierstoffe, Phthalsäureester, PAH; Quecksilberaerosol und –dampf, Bitumen, Mineralöle Ausgewählte Parameter: N-Nitrosamine, Isocyanate (Monomere und Polymere), Dieselmotoremissionen, Pharmawirkstoffe die Kompetenz für die Ermittlung und Beurteilung der Konzentrationen gefährlicher Stoffe in der Luft in Arbeitsbereichen gemäß Gefahrstoffverordnung § 7, Abs. 10 bestätigt. Verwendete Abkürzungen: AA Arbeitsanweisung ANECO Institut für Arbeitsschutz DGUV Deutsche gesetzliche Unfallversicherung DFG Deutsche Forschungsgemeinschaft DIN Deutsches Institut für Normung EN Europäische Norm IEC International Electrotechnical Commission IFA Berufsgenossenschaftliches Institut für Arbeitssicherheit ISO International Organization for Standardization NIOSH National Institute for Occupational Safety and Health OSHA Occupational Safety and Health Administration VA Verfahrensanweisung ANECO Institut für Arbeitsschutz
-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Wehnerstraße 1-7, Mönchengladbach, 41068, DE

51.19596, 6.42022

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.