Registers refreshed 2026-11-20.See refresh dates
United States

Turf & Soil Diagnostics

613 E. 1st Street, 66052, Linwood, KS, United States

Visit website
A2LA 797.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
18
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 18 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM18
ASTM C29
ASTM C136
ASTM C702
ASTM D854
ASTM D2216
ASTM D2974
ASTM D4972
ASTM D5550
ASTM D6928
ASTM E2396
ASTM E2397
ASTM E2398
Show all 18
ASTM E2399
ASTM F355
ASTM F1632
ASTM F1647
ASTM F1815
ASTM F1936

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

797.01

The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 797.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; ASTM C29/C29M; ASTM C136/C13M; ASTM C702/C702M; ASTM D854; ASTM D2216; ASTM D2974; ASTM D4972; ASTM D5550; ASTM D6928; ASTM E2396/E2396M; ASTM E2397/E2397M; ASTM E2398/E2398M; ASTM E2399/E2399M; ASTM F355; ASTM F1632; ASTM F1647; ASTM F1815; ASTM F1936Soil-
2Infiltration Rate SOP; Determination of size factors SOP; Angle of Repose SOP--
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Geotechnical/Putting Green Materials Scope of Accreditation. Accredited Laboratory A2LA has accredited TURF & SOIL DIAGNOSTICS, INC. Linwood, KS for technical competence in the field of Geotechnical/Putting Green Materials Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of any additional program requirements in the Geotechnical field. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 19th day of January 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 0797.01 Valid to March 31, 2026 Revised February 16, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

613 E. 1st Street, Linwood, KS, 66052, US

39.00139, -95.03914

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.