ACQUE SPA - Laboratorio
Via del Castelluccio, 50053, Empoli, Italy
Visit website- Accredited standards
- 21
- ACCREDIA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 21 standard numbers and the 18 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO17
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7887Water quality - Examination and determination of colourSome methods
Limits written next to it
ISO 7887:2011 - solo/only Metodo C
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 10301Water quality - Determination of highly volatile halogenated hydrocarbons - Gas-chromatographic methods
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 10705-2Water quality - Detection and enumeration of bacteriophages - Part 2: Enumeration of somatic coliphages
ISO 11731Water quality - Enumeration of Legionella
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 14911Water quality - Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography - Method for water and waste water
Show all 17
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 15923-1Water quality - Determination of selected parameters by discrete analysis systems - Part 1: Ammonium, nitrate, nitrite, chloride, orthophosphate, sulfate and silicate with photometric detection
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
ISO 21676Water quality - Determination of the dissolved fraction of selected active pharmaceutical ingredients, transformation products and other organic substances in water and treated waste water - Method using high performance liquid chromatography and mass spectrometric detection (HPLC-MS/MS or -HRMS) after direct injection
ISO 23695Water quality - Determination of ammonium nitrogen in water - Small-scale sealed tube method
Other standards4
APAT CNR IRSA 2110 Man 29 2003
APAT CNR IRSA 7030 F Man 29 2003
EN 17892Water quality - Determination of selected per- and polyfluoroalkyl substances in drinking water - Method using liquid chromatography/tandem-mass spectrometry (LC-MS/MS)Some clauses
Limits written next to it
UNI EN 17892:2024 - solo/only parte
EPA 7473
UNI CEI EN ISO/IEC 17025:2018; Rapporti ISTISAN 2007/31; UNI 11759:2019; MU 2252:08; APAT CNR IRSA 2110 Man 29 2003; ISO 14189:2013; UNI EN ISO 14911:2001; ISO 7887:2011; UNI EN ISO 6222:2001; UNI EN ISO 7899-2:2003; ISO 11731:2017
UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 9308-2:2014; Rapporti ISTISAN 2007/31 pag 65 Met ISS BFA032; APAT CNR IRSA 7080 Man 29 2003; MI-003 Rev. 3 2023; APAT CNR IRSA 3150 C Man 29 2003; EPA 7473 2007; UNI EN ISO 10705-2:2001; APAT CNR IRSA 4050 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 9308-1:2017; AFNOR IDX 33/03-10/13; AFNOR BRD 07/16-12/07; AFNOR BRD 07/15-12/07; APAT CNR IRSA 5120 B2 Man 29 2003
Rapporti ISTISAN 2007/31 pag 126; Met ISS CBB006; UNI EN ISO 21676:2021; UNI EN ISO 17294-2:2023; Rapporti ISTISAN 2019/07 pag 134; Met ISS CBA050; UNI EN ISO 10304-1:2009; EVS EN ISO 10304-4:2022; ISO 10304-4:2022; UNI EN ISO 10304-4:2022; UNI EN ISO 10301:1999
UNI CEI EN ISO/IEC 17025:2018; UNI EN 17892:2024; ISO 15923-1:2013; Rapporti ISTISAN 2019/07; APAT CNR IRSA 7030 F Man 29 2003; MU 71:01; APAT CNR IRSA 4050 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; MI-001 Rev2 2022; ISO 15705:2002; MI-002 Rev3 2021; APAT CNR IRSA 3010 A + 3020 Man 29 2003; UNI EN ISO 10304-1:2009; ISO 23695:2023; ISO 15923-1:2013; APAT CNR IRSA 2030 Man 29 2003
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
6 lines
ISO/IEC 17025
Active01104
Accredited scope, certificate 01104
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 9308-2:2014; Rapporti ISTISAN 2007/31 pag 65 Met ISS BFA032; APAT CNR IRSA 7080 Man 29 2003; MI-003 Rev. 3 2023; APAT CNR IRSA 3150 C Man 29 2003; EPA 7473 2007; UNI EN ISO 10705-2:2001; APAT CNR IRSA 4050 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 9308-1:2017; AFNOR IDX 33/03-10/13; AFNOR BRD 07/16-12/07; AFNOR BRD 07/15-12/07; APAT CNR IRSA 5120 B2 Man 29 2003 | Drinking water | See scope document |
| 2 | UNI CEI EN ISO/IEC 17025:2018; Rapporti ISTISAN 2007/31; UNI 11759:2019; MU 2252:08; APAT CNR IRSA 2110 Man 29 2003; ISO 14189:2013; UNI EN ISO 14911:2001; ISO 7887:2011; UNI EN ISO 6222:2001; UNI EN ISO 7899-2:2003; ISO 11731:2017 | Drinking water | 10 to µg/L |
| 3 | Rapporti ISTISAN 2007/31 pag 126; Met ISS CBB006; UNI EN ISO 21676:2021; UNI EN ISO 17294-2:2023; Rapporti ISTISAN 2019/07 pag 134; Met ISS CBA050; UNI EN ISO 10304-1:2009; EVS EN ISO 10304-4:2022; ISO 10304-4:2022; UNI EN ISO 10304-4:2022; UNI EN ISO 10301:1999 | Drinking water | See scope document |
| 4 | UNI CEI EN ISO/IEC 17025:2018; Rapporti ISTISAN 2019/07 pag 151; Met ISS CBA052 | - | - |
| 5 | UNI CEI EN ISO/IEC 17025:2018; UNI EN 17892:2024; ISO 15923-1:2013; Rapporti ISTISAN 2019/07; APAT CNR IRSA 7030 F Man 29 2003; MU 71:01; APAT CNR IRSA 4050 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; MI-001 Rev2 2022; ISO 15705:2002; MI-002 Rev3 2021; APAT CNR IRSA 3010 A + 3020 Man 29 2003; UNI EN ISO 10304-1:2009; ISO 23695:2023; ISO 15923-1:2013; APAT CNR IRSA 2030 Man 29 2003 | Acque di scarico anche sottoposte a trattamento/Waste waters also treated; Acque di scarico/Waste waters, Acque naturali/Natural waters; Acque di scarico/Waste waters, Acque sotterranee/Ground waters, Acque superficiali/Surface waters; Acque sotterranee (1)/Ground waters (1), Acque superficiali (1)/Surface waters (1) | - |
| 6 | UNI CEI EN ISO/IEC 17025:2018; CNR IRSA 1 Q 64 Vol 2 1984 | - | 0.01 to g/L |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in Italy
- VeronaLabVillafranca Fraz. Dossobuono · ~188 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2110 Man 29 2003EN ISO 17294-2:2023Drinking water
- ECOGEOLAB S.R.L. - a socio unicoBergamo · ~242 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2110 Man 29 2003APAT CNR IRSA 7030 F Man 29 2003Drinking water
- INNOVAZIONE CHIMICAMotta di Livenza · ~265 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 7030 F Man 29 2003EN ISO 17294-2:2023Drinking water
- BRACHI TESTING SERVICESPrato · ~22 kmACCREDIAShares 2 accredited methods and materialsEN ISO 17294-2:2023Drinking water
- BIOCHEMIE LAB S.r.l.Campi Bisenzio · ~24 kmACCREDIAShares 2 accredited methods and materialsEN ISO 17294-2:2023Drinking water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.