CHEBA. Laboratorium Inżynierii Środowiska. Badania Środowiska Pracy
ul. Wał Miedzeszyński 184, 04-987, Warszawa, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
No contact information available
Open PCA register entryWork at CHEBA. Laboratorium Inżynierii Środowiska. Badania Środowiska Pracy?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 843Active
Certificates and scope
1ISO/IEC 17025
ActiveAB 843
The scope document we hold says it is valid until 2027-10-14.
Accredited scope, certificate AB 843
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | environmental | - | środowisko pracy (czynniki szkodliwe – powietrze); środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, hałas ultadźwiękowy, drgania, mikroklimat, nielaserowe promieniowanie optyczne), general environment (physical factors – noise); środowisko pracy czynniki szkodliwe – powietrze | - |
| 2 | environmental | PN-Z-04008-7:2002; PN-Z-04008-7:2002+ Az1:2004; PB-07; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08 | Ambient air | 0.09 to 232 mg/m3 |
| 3 | environmental | PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PN-N-01307:1994; PN-EN ISO 9612:2011; PN-Z-01339:2020-12; Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023, poz. 1706) | Ambient air | 0.08 to 159 mg/m3; dB |
| 4 | environmental | PN-EN-ISO 5349-1:2004; PN-EN-ISO 5349-2:2004; PN-EN-ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011 | Workplace environment | 0.04 to 316 m/s2; m/s² |
| 5 | environmental | PN-EN ISO 7730:2006+Ap2:2016-04; PN-EN 7243:2018-01; PN-EN ISO 11079:2008 | Workplace environment | 10 to 30 ºC |
| 6 | environmental | PN-EN 14255-1:2010; PN-EN 14255-2:2010; PN-T-05687:2002 pkt. 2.5.5; PN-T-05687:2002 pkt. 2.5.4 | Workplace environment | 0.000001 to 39900 W/m2 |
| 7 | environmental | PN-EN 12198-1+A1:2010; PN-EN 12198-2+A1:2010 | Źródła promieniowania lub maszyny | 0.00001 to 3999 W/m2 |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Firma Usługowa "RMS" - Pomiary Środowiskowe Bogdan RadkoJaworzno · ~258 kmPCAShares 5 accredited methods and materialsEN 14253+A1:2011PN-Z-04008-7:2002PN-Z-04508:2022-05
- Silesia Lab Sp. z o.o.Katowice · ~260 kmPCAShares 5 accredited methods and materialsEN 14253+A1:2011PN-Z-04008-7:2002PN-Z-04508:2022-05
- Techno-Service Pracownia Badań ŚrodowiskowychGdańsk · ~287 kmPCAShares 5 accredited methods and materialsEN 14253+A1:2011EN ISO 11079:2008PN-Z-04508:2022-05
- ZEC DIAGPOMWrocław · ~308 kmPCAShares 5 accredited methods and materialsEN 14253+A1:2011PN-Z-04008-7:2002PN-Z-04508:2022-05
- EKOLAB Sp. z o.o.Kobylnica · ~365 kmPCAShares 5 accredited methods and materialsEN ISO 11079:2008PN-Z-04008-7:2002PN-Z-04508:2022-05
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.