Registers refreshed 2026-11-20.See refresh dates
Germany

WSPLab + Cert GmbH WSPLab

Kapuzinerweg 7, 70374, Stuttgart, Germany

Visit website
DAKKS D-PL-11156-01-00ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
18
DAKKS certificate
1
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 18 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

EN9
EN 215
EN 442-1
EN 442-2
EN 834
EN 1264-2
EN 1264-5
EN 14240
EN 14518
EN 15116
EN 14037 series5
EN 14037-1
EN 14037-2
EN 14037-3
EN 14037-4
EN 14037-5
EN 16430 series3
EN 16430-1
EN 16430-2
EN 16430-3
Other standards1
ISO 2409Paints and varnishes - Cross-cut test

Read from the scope as published by DAKKS. Register refreshed 2026-11-20.

Scope as published by DAKKS

5 lines
DAKKS

ISO/IEC 17025

Active

D-PL-11156-01-00

View scope

Accredited scope, certificate D-PL-11156-01-00

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018Bauteilen und Anlagen der Heizungs-, Lüftungs- und Klimatechnik; Bauprodukten-
2DIN EN ISO 2409; DIN EN 215; DIN EN 442 -1; DIN EN 442 -2; DIN EN 834; DIN EN 1264 -2Bauteile der Heizungs-, Lüftungs- und Klimatechnik; Beschichtungsstoffe; Thermostatische Heizkörperventile; Radiatoren und Konvektoren; Heizkostenverteiler-
3DIN EN 1264 -5; DIN EN 14037 -1; DIN EN 14037 -2; DIN EN 14037 -3; DIN EN 14037 -4; DIN EN 14037 -5; DIN EN 14240; DIN EN 14518; DIN EN 15116--
4DIN EN 16430 -1; DIN EN 16430 -2; DIN EN 16430 -3; CEN/TR 15500 -2; EN 14037 -1:2016; EN 442 -1:2014-to 120 °C
5DIN; EN; VDI--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Kapuzinerweg 7, Stuttgart, 70374, DE

48.81791, 9.25218

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.