Przedsiębiorstwo Badań Środowiska "SANUM" S.C. Henryk Gracka, Marek Lepiorz, Krzysztof Bloch, Jakub Łubiński
ul. Radoszowska 46, 41-707, Ruda Śląska, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Przedsiębiorstwo Badań Środowiska "SANUM" S.C. Henryk Gracka, Marek Lepiorz, Krzysztof Bloch, Jakub Łubiński?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 821Active
Certificates and scope
1ISO/IEC 17025
ActiveAB 821
The scope document we hold says it is valid until 2027-08-26.
Accredited scope, certificate AB 821
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | environmental | - | working environment (harmful factors - air); working environment (harmful and nuisance factors – noise, lighting, vibration, microclimate); general environment (physical factors - noise); facilities (environmental conditions - noise) | - |
| 2 | environmental | PN-N-01307:1994; PN-EN ISO 9612:2011; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706); PN-87/B-02156; PN-83/E-04040.03; PN-EN 1838:2005 | Workplace environment | 0.5 to 10000 lx; dB; s |
| 3 | environmental | PN-EN 1838:2013-11; PN-EN ISO 7730:2006; PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01; PN-EN ISO 7243:2018-01/Ap2:2020-04 | Workplace environment | 0.5 to 500 lx |
| 4 | environmental | PN-EN 14253+A1:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11 | Workplace environment | 0.0316 to 50 m/s² |
| 5 | chemical | PN-Z-04008-7:2002 + Az1:2004; PN-91/Z-04030/05; PN-91/Z-04030/06 | Ambient air | 0.09 to 23.67 mg/m3 |
| 6 | environmental | PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08 | Ambient air | 0.09 to 25.42 mg/m3 |
| 7 | chemical | PN-Z-04450:2014-08; PN-71/Z-04041 | Ambient air | 0.02 to 162.4 mg/m3; ppm; mg w próbce |
| 8 | environmental | PN-Z-04108-5:2006; Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130; PN-Z-04472:2015-10 + Ap1:2015-12; PN-Z-04106-3:2002; PN-Z-04100-3:1987; PN-Z-04469:2025-02 | Ambient air | 0.0047 to 22.7 mg/m3 |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Laboratorium SMC Spółka z ograniczoną odpowiedzialnościąMichałowice · ~158 kmPCAShares 6 accredited methods and materialsEN 14253+A1:2011EN ISO 7730:2006PN-N-01307:1994
- dB-lux Laboratorium Środowiska Pracy Spółka z ograniczoną odpowiedzialnością Spółka komandytowaChojnów · ~234 kmPCAShares 6 accredited methods and materialsEN 14253+A1:2011EN ISO 7730:2006PN-N-01307:1994
- Zakład Ochrony Środowiska i Higieny Pracy "BIOSAN" Gizela Kalinowska, Ryszard KalinowskiPiła · ~350 kmPCAShares 6 accredited methods and materialsEN 14253+A1:2011EN ISO 7730:2006PN-N-01307:1994
- Centrum Badań Środowiska "SORBCHEM"Ruda Śląska · under 1 kmPCAShares 5 accredited methods and materialsEN ISO 7730:2006PN-71/Z-04041PN-N-01307:1994
- SBB Laboratorium Badań i EkspertyzKatowice · ~12 kmPCAShares 5 accredited methods and materialsEN ISO 7730:2006PN-71/Z-04041PN-N-01307:1994
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.