Registers refreshed 2026-11-20.See refresh dates
Italy

LABORATORI FRATINI - Unità locale ECOCHEM S.p.A. a socio unico

Via Ludovico Lazzaro Zamenhof 22, 36100, Vicenza, Italy

Visit website
ACCREDIA 00585ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
27
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 27 standard numbers and the 24 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO24
ISO 2917Meat and meat products - Measurement of pH - Reference method
ISO 4832Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coliforms - Colony-count technique
ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
ISO 4833-2Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 2: Colony count at 30 °C by the surface plating technique
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
ISO 6888-2Microbiology of the food chain - Horizontal method for the enumeration of coagulase-positive staphylococci (Staphylococcus aureus and other species) - Part 2: Method using rabbit plasma fibrinogen agar medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 7932Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of presumptive Bacillus cereus - Colony-count technique at 30 degrees C
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 10272-2Microbiology of the food chain - Horizontal method for detection and enumeration of Campylobacter spp. - Part 2: Colony-count technique
ISO 10390Soil, treated biowaste and sludge - Determination of pH
Show all 24
ISO 11290-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 2: Enumeration method
ISO 11465Sludge and solid environmental matrices - Determination of dry residue or water content and calculation of the dry matter fraction on a mass basis
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18, EN ISO 11731:2017. Probably the same standard; not checked against the EN document.

ISO 13720Meat and meat products - Enumeration of presumptive Pseudomonas spp.
ISO 15213-1Microbiology of the food chain - Horizontal method for the detection and enumeration of Clostridium spp. - Part 1: Enumeration of sulfite-reducing Clostridium spp. by colony-count technique
ISO 15214Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of mesophilic lactic acid bacteria - Colony-count technique at 30 degrees C
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 16649-2Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli - Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide
ISO 17604Microbiology of the food chain - Carcass sampling for microbiological analysis
ISO 18593Microbiology of the food chain - Horizontal methods for surface sampling
ISO 19458Water quality - Sampling for microbiological analysis
ISO 21527-1Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of yeasts and moulds - Part 1: Colony count technique in products with water activity greater than 0,95
Other standards3
APAT CNR IRSA 1030 Man 29 2003
EN 14735Exclusion

Limits written next to it

UNI EN 14735:2022 + OECD Guideline for the testing of chemicals N. 202 - 2004 - escluso/except par. 4 e 11

Exclusion. Written next to it on line 3 of ACCREDIA certificate 00585.

NF T 90-412

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

4 lines
ACCREDIA

ISO/IEC 17025

Active

00585

View scope

Accredited scope, certificate 00585

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 11731:2017; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 7080 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 6222:2001; NF T90-412:2016; UNI EN ISO 16266:2008; UNI EN ISO 9308-1:2017; ISO 7899-2:2000Drinking waterSee scope document
2ISO 21527-1:2008; UNI EN ISO 7932:2020; ISO 15213-1:2023; AFNOR BIO 12/17-12/05; ISO 16649-2:2001; AFNOR BIO 12/13-02/05; UNI EN ISO 11290-2:2017; AFNOR BIO 12/28-04/10; UNI EN ISO 10272-2:2023; UNI EN ISO 4833-1:2022; UNI EN ISO 6579-1:2020; UNI EN ISO 4833-2:2022; ISO 15214:1998; AFNOR BIO 12/21-12/06; AFNOR BIO 12/35-05/13Food industry environment samples-
3UNI CEI EN ISO/IEC 17025:2018; AFNOR BIO 12/41-03/17; ISO 4832:2006; AFNOR AES 10/03-09/00; ISO 6888-2:2021/Amd 1:2023; MU 1962-2:06; ISO 2917:1999; ISO 13720:2010; APAT 3 Man 20 2003; UNI EN 14735:2022 + OECD Guideline for the testing of chemicals N. 202 - 2004 - escluso/except par. 4 e 11; ISO 10390:2021; ISO 11465:1993/Cor 1:1994; ISO 17604:2015 solo cap 10 + AFNOR BIO 12/21-12/06; ISO 18593:2018 escl cap 7 + AFNOR BIO 12/21-12/06; ISO 18593:2018 escl cap 7 e 8 + ISO 16649-2:2001; ISO 18593:2018 escl cap 7 e 8 + ISO 21527-1:2008Food industry environment samples4 to 10 pH
4APAT CNR IRSA 1030 Man 29 2003; UNI EN ISO 19458:2006; ISO 17604:2015; ISO 18593:2018Waste water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Ludovico Lazzaro Zamenhof 22, Vicenza, 36100, IT

45.53009, 11.58931

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.