Registers refreshed 2026-11-20.See refresh dates
Italy

Lario Reti Holding

Via Fiandra, 13, 23900, Lecco, Italy

Visit website
ACCREDIA 01487ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
6
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16266-2Water quality - Detection and enumeration of Pseudomonas aeruginosa - Part 2: Most probable number method
ISO 23695Water quality - Determination of ammonium nitrogen in water - Small-scale sealed tube method

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

1 line
ACCREDIA

ISO/IEC 17025

Active

01487

View scope

Accredited scope, certificate 01487

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 6222:2001; UNI EN ISO 9308-1:2017; UNI EN ISO 7899-2:2003; UNI EN ISO 16266-2:2022; UNI 11759:2019; MU 2252:08; APHA Standard Methods for Examination of Water and Wastewater 5210 D (2019); ISO 15705:2002; APAT CNR IRSA 2090 B Man 29 2003; APAT CNR IRSA 3010 B + 3020 Man 29 2003; UNI ISO 23695:2023Drinking water0.4 to 60 mg/l NH4+

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Fiandra, 13, Lecco, 23900, IT

45.90055, 9.41202

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.