Eurofins Materials Science Netherlands
Eindhoven, Netherlands
- Accredited standards
- 63
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 63 standard numbers and the 39 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM14
ASTM C813
ASTM D543
ASTM D5296
ASTM D5946
ASTM E334
ASTM E766
ASTM E1019Standard Test Methods for Determination of Carbon, Sulfur, Nitrogen, and Oxygen in Steel, Iron, Nickel, and Cobalt Alloys by Combustion and Inert Gas Fusion Techniques
ASTM E1252
ASTM E1409
ASTM E1447
ASTM E1508
ASTM E1941
ASTM F2129
ASTM F3044
ISO13
ISO 527-2Plastics - Determination of tensile properties - Part 2: Test conditions for moulding and extrusion plastics
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 11979-2Ophthalmic implants - Intraocular lenses - Part 2: Optical properties and test methods
ISO 11979-5Ophthalmic implants - Intraocular lenses - Part 5: Biocompatibility
ISO 11981Ophthalmic optics - Contact lenses and contact lens care products - Determination of physical compatibility of contact lens care products with contact lenses
ISO 11986Ophthalmic optics - Contact lenses and contact lens care products - Determination of preservative uptake and release
ISO 14949Implants for surgery - Two-part addition-cure silicone elastomers
ISO 15472Surface chemical analysis - X-ray photoelectron spectrometers - Calibration of energy scales
ISO 18369-3Ophthalmic optics - Contact lenses - Part 3: Measurement methods
ISO 19227Implants for surgery - Cleanliness of orthopedic implants - General requirements
ISO 22088-3Plastics - Determination of resistance to environmental stress cracking (ESC) - Part 3: Bent strip method
ISO 22963Titanium and titanium alloys - Determination of oxygen - Infrared method after fusion under inert gas
ISO 24237Surface chemical analysis - X-ray photoelectron spectroscopy - Repeatability and constancy of intensity scale
IEC 60068 series10
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-5
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-66
IEC 60068-2-75
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ISO 14708 series7
ISO 14708-1Implants for surgery - Active implantable medical devices - Part 1: General requirements for safety, marking and for information to be provided by the manufacturer
ISO 14708-2Implants for surgery - Active implantable medical devices - Part 2: Cardiac pacemakers
ISO 14708-3Implants for surgery - Active implantable medical devices - Part 3: Implantable neurostimulators
ISO 14708-4Implants for surgery - Active implantable medical devices - Part 4: Implantable infusion pump systems
ISO 14708-5Implants for surgery - Active implantable medical devices - Part 5: Circulatory support devices
ISO 14708-6Implants for surgery - Active implantable medical devices - Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)
ISO 14708-7Implants for surgery - Active implantable medical devices - Part 7: Particular requirements for cochlear and auditory brainstem implant systems
IEC 62321 series6
IEC 62321-3-1
IEC 62321-3-2
IEC 62321-4
IEC 62321-5
IEC 62321-7-1
IEC 62321-7-2
ISO 18562 series4
ISO 18562-1Biocompatibility evaluation of breathing gas pathways in healthcare applications - Part 1: Evaluation and testing within a risk management process
ISO 18562-2Biocompatibility evaluation of breathing gas pathways in healthcare applications - Part 2: Tests for emissions of particulate matter
ISO 18562-3Biocompatibility evaluation of breathing gas pathways in healthcare applications - Part 3: Tests for emissions of volatile organic substances
ISO 18562-4Biocompatibility evaluation of breathing gas pathways in healthcare applications - Part 4: Tests for leachables in condensate
ISO 10993 series3
ISO 10993-12Biological evaluation of medical devices - Part 12: Sample preparation and reference materials
ISO 10993-15Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys
ISO 10993-18Biological evaluation of medical devices - Part 18: Chemical characterization of medical device materials within a risk management process
ISO 14644 series3
ISO 14644-1Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration
ISO 14644-5Cleanrooms and associated controlled environments - Part 5: Operations
ISO 14644-7Cleanrooms and associated controlled environments - Part 7: Separative devices (clean air hoods, gloveboxes, isolators and mini-environments)
Other standards3
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 62262
USP 788
ISO 11979-2; ISO 11979-5; ISO 11981; ISO 11986; ISO 18369-3; SOP 60/F1; ASTM C813; ASTM D5946; ASTM F2129; ASTM F3044; ISO 10993-15; SOP 37/F5; ASTM D5296; SOP 53/F1; GMW8287; SOP 11/F1; ISO 15472; ISO 24237; SOP 03/F/F1; ASTM E1252; ASTM E334; ISO 10993-12; ISO 10993-18; SOP 25/F1
SOP 26/F1; SOP 49/F1; SOP 54/F1; ISO 527-2; ISO 22088-3; ASTM D543; SOP 55/F1; SOP 50/F1; USP 788; ISO 19227; ISO 14708-1; ISO 14708-2; ISO 14708-3; ISO 14708-4; ISO 14708-5; ISO 14708-6; ISO 14708-7; SOP 48/F1; ISO 14644-1:2015; ISO 14644-5:2004; ISO 14644-7:2004; ISO 14644-1:1999; ISO 18562-1; ISO 18562-2; SOP 66/F1; SOP 13/F1; SOP 52/F1; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; IEC 60068-2-30; IEC 60068-2-66; IEC 60068-2-78; SOP 52/F2; IEC 60068-2-75; EN 62262; SOP 52/F3; IEC 60529; SOP 52/F4; IEC 60068-2-52; ISO 9227
SOP 09/F1; SOP 06/F1/F14/F17; ASTM E766; ASTM E1508; SOP 02/F6; SOP 44/F1; SOP 14/F1/F6/F7/F8/F9; IEC 62321-3-1; SOP 21/F1; SOP 33/F3; SOP 33/F4; SOP 24/F1; IEC 62321-3-2; SOP 18/F1/F12; IEC 62321-4; IEC 62321-5; IEC 62321-7-1; IEC 62321-7-2; ISO 10993-12; ISO 10993-18; ISO 14949; ISO 18562-1; ISO 18562-4; SOP 18/F1/F12; ISO 18562-1; ISO 18562-4; IEC 62321-4; IEC 62321-5; SOP 18/F9; SOP 19/F1; ISO 22963; ASTM E1019; ASTM E1941; ASTM E1409; ASTM E1447; SOP 41/F1/F5; ISO 10993-12; ISO 10993-18; ISO 18562-1; ISO 18562-3; ISO 18562-4
SOP 52/F5; IEC 60068-2-5; SOP 52/F6; IEC 60068-2-27; SOP 40/F4; SOP 22/F5; SOP 46/F1; SOP 47/F1; SOP 16/F1; SOP29/F2; GC-MS; ISO 18562-1; ISO 18562-3; ISO 18562-4; ISO 10993-12; ISO 10993-18
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active2797.09
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 2797.09
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 11979-2; ISO 11979-5; ISO 11981; ISO 11986; ISO 18369-3; SOP 60/F1; ASTM C813; ASTM D5946; ASTM F2129; ASTM F3044; ISO 10993-15; SOP 37/F5; ASTM D5296; SOP 53/F1; GMW8287; SOP 11/F1; ISO 15472; ISO 24237; SOP 03/F/F1; ASTM E1252; ASTM E334; ISO 10993-12; ISO 10993-18; SOP 25/F1 | semiconductors; integrated circuits; communication and storage devices; photovoltaic materials; consumer products; optical components; thin film products; biomedical materials and products; pharmaceutical products; packaging materials; composites; metals; alloys; plastics; polymers; glasses; ceramics; powders; nanomaterials; Ophthalmic optics – Intraocular lenses, contact lenses and contact lens care products | - |
| 2 | SOP 09/F1; SOP 06/F1/F14/F17; ASTM E766; ASTM E1508; SOP 02/F6; SOP 44/F1; SOP 14/F1/F6/F7/F8/F9; IEC 62321-3-1; SOP 21/F1; SOP 33/F3; SOP 33/F4; SOP 24/F1; IEC 62321-3-2; SOP 18/F1/F12; IEC 62321-4; IEC 62321-5; IEC 62321-7-1; IEC 62321-7-2; ISO 10993-12; ISO 10993-18; ISO 14949; ISO 18562-1; ISO 18562-4; SOP 18/F1/F12; ISO 18562-1; ISO 18562-4; IEC 62321-4; IEC 62321-5; SOP 18/F9; SOP 19/F1; ISO 22963; ASTM E1019; ASTM E1941; ASTM E1409; ASTM E1447; SOP 41/F1/F5; ISO 10993-12; ISO 10993-18; ISO 18562-1; ISO 18562-3; ISO 18562-4 | - | - |
| 3 | SOP 26/F1; SOP 49/F1; SOP 54/F1; ISO 527-2; ISO 22088-3; ASTM D543; SOP 55/F1; SOP 50/F1; USP 788; ISO 19227; ISO 14708-1; ISO 14708-2; ISO 14708-3; ISO 14708-4; ISO 14708-5; ISO 14708-6; ISO 14708-7; SOP 48/F1; ISO 14644-1:2015; ISO 14644-5:2004; ISO 14644-7:2004; ISO 14644-1:1999; ISO 18562-1; ISO 18562-2; SOP 66/F1; SOP 13/F1; SOP 52/F1; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; IEC 60068-2-30; IEC 60068-2-66; IEC 60068-2-78; SOP 52/F2; IEC 60068-2-75; EN 62262; SOP 52/F3; IEC 60529; SOP 52/F4; IEC 60068-2-52; ISO 9227 | water; particles | - |
| 4 | SOP 52/F5; IEC 60068-2-5; SOP 52/F6; IEC 60068-2-27; SOP 40/F4; SOP 22/F5; SOP 46/F1; SOP 47/F1; SOP 16/F1; SOP29/F2; GC-MS; ISO 18562-1; ISO 18562-3; ISO 18562-4; ISO 10993-12; ISO 10993-18 | water | - |
| 5 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Accreditation data refreshed from the A2LA register on .